• Title/Summary/Keyword: Disaster Prevention IT Technology

Search Result 416, Processing Time 0.027 seconds

Analysis of the Evacuation Safety with the Structure and Opening/Closing of Exits in a Fire at a Highway Service Area (고속도로 휴게소 화재 시 출입문의 구조와 개폐에 따른 피난안전성 분석)

  • Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.419-425
    • /
    • 2021
  • This study analyzed the safety of evacuation according to the number of exits and the direction of evacuation routes with evacuation simulations of the Pathfinder in case of a fire at a highway service area. It was also analyzed of the difference in RSET by comparing the single or double types of the exit of a facility. The results were as follows. When only one direction exit was opened, all of the RSET were exceeded. When two or more different directions were opened according to the general principle of evacuation, all results met the RSET. The simulations showed that two or more different directions were more shortened in RSET than the one same direction. The result of the types of doors showed that the single type door was shortened in RSET rather than the double type doors. For the evacuation safety in a fire at the highway service areas, firstly, it is necessary to secure two or more exits in a fire at all times. Secondly, the exits should not be same directions. Finally, it is suggested that the exit should be installed with a single type of door.

Investigation on the operational state of the public food waste treatment facilities and suggestions on their efficient operational management (음식물류폐기물 공공 자원화시설의 운영실태 조사를 통한 처리공정별 효율적인 운영방안 검토)

  • Jang, Yun-Hyeok;Park, Joon-Seok;Kim, Joung-Dae;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.47-56
    • /
    • 2010
  • At present, 265 national food waste recycling facilities have been operated by public facilities 95 and private facilities 160. it has continuously installed a food waste treatment facility from 1997. The government set up and implemented guidelines and inspection standards for the installation and operation of the facilities. However, unclear detailed examination items, designs and process standards for the installation procedures of the facilities are causing problems due to the unskilled operation management system, decrease in efficiency and defects of a facility. This study conducted mail and site surveys on 95 public food waste recycling facilities that it suggest the ways to operate facilities which minimize problems. At the result of investigation, a pre-treatment facility was not installed 2 systems(2 inputting facilities) and hopper covers and food was overloaded. also the transportation amount was excessive. In case of a main treatment facility, the secondary environmental pollution was caused by inexperienced operation and the efficiency of the facility was reduced due to excessive input of food. also the operation management standards of the facilities were inappropriate. The odor and food waste leachate treatment facility is investigated as problems that are unskilled operation, lack of regular inspection and inappropriate capacity of the treatment facility. Based on the problems found through the investigation, it suggested some ways of efficient operation. this study might contribute to minimize mistakes and defects and improve the efficiency of install and operation course of food waste recycling facilities through finding.

Effects of the Safety and Health Management System on the Performance of the Enterprise: Focus on the Electric Power Corporation (안전보건경영시스템의 운영방침이 기업성과에 미치는 영향: 전기공사업을 중심으로)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • This research is mainly aimed at finding out about the effects of the safety and health management system on corporate performance through systematic operation by efficiently allocating material and human resources within the company by participating all employees and stakeholders in order to prevent and maintain industrial accidents and the optimal working environment, and how to maintain and activate the safety and health management system at the center of electric contractors.The analysis results are as follows. First, management, organizational management and resource preparation will have a positive impact on the management capability of the electric power corporation. It was assessed that the more well-transmitted and understood within the organization, the better the construction plan, the better the equipment management status, the more positively the management capability of electric works was to be achieved. Second, management, organizational management and resource preparation will have a positive impact on corporate management performance.This seems to have a positive effect on a company's business performance when the standards of OHSAS are met with construction plan and construction equipment management are high as related information such as industrial safety and health laws are strengthened and companies' safety and health activities, advanced safety and culture are released to facilitate organizational management.Third, the management ability of the electric power corporation will have a mediated effect on the effect of management, organization management and resource preparation on the performance of the enterprise. This means that the direct effect of the independent variable management organization on corporate management performance is .401 The indirect effect is .168.658 shows that the direct effect of resource preparation on corporate management performance is .423, the indirect effect is .178 and the total effect.It was analyzed at 643.

A Field Test on Bearing Capacity Characteristics of Materials for Ground Cavity Restoration Based on Plate Bearing Test (평판재하시험을 이용한 공동 복구재료의 지지특성에 관한 현장실험)

  • Park, Jeong-Jun;Shin, Heesoo;Kim, Dongwook;You, Seung-Kyong;Yun, Jung-Mann;Hong, Gigwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.293-304
    • /
    • 2018
  • This paper described a results of field test based on plate bearing test of the restoration material, which was developed to restore the ground cavity due to sewerage damage. The analysis of bearing capacity characteristics on the restoration materials was performed by experimental results. The results showed that the load bearing capacity in the maximum stress condition of the foundation ground is about 66%-70%, when the expansion mat is embedded at the bottom of 0.1 m and 0.2 m from the ground surface. However, The load bearing capacity of expansion mat according to embedded depth was not large. The load bearing capacity of concrete mats was about 82%-90% compared with that of ground surface, and it showed about 50% of the load bearing capacity compared with the expansion mat. As a result of analysis of allowable bearing capacity according to restoration materials, it was confirmed that the allowable bearing capacity of the expansion mat and the concrete was about 130%-150% and about 160% more than the foundation ground, respectively.

Study on the Management Plan for the Preparation of Chemical Terrorism in Multi-use Facilities (다중이용시설 화학테러에 대비한 관리방안 연구)

  • Yoon, Seong Yong;Kim, Si-Kuk;Hong, Sungchul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.68-78
    • /
    • 2019
  • In modern society, the paradigm of terrorism is shifting to the form of soft targets focusing on an unspecified number of people, which is different from previous terrorist tendencies, and frequent attacks using chemicals. Therefore, this study analyzed the evacuation environment and characteristics, manual analysis of a terror response manual, and the domestic chemical management status of multi-use facilities, and proposed the following management measures for chemical terror prevention in multi-use facilities. First, a multi-use facility guideline for prompt onsite response is proposed. Second, an improvement plan is suggested through the analysis of the manual for counter terrorism. Third, integrated management is proposed through the selection of chemicals available for terrorism. Through this, it is expected that an additional improvement plan will be prepared for countermeasures against chemical terrorism in multi-use facilities. In the future, it will be necessary to analyze the problems through cases of foreign countries and take customized countermeasures.

The Floor Layout Plan of Classrooms for Securing Evacuation Stability in School (학교의 피난 안전성 확보를 위한 층별 학급 배치방안)

  • Lee, Soon Beom;Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.509-515
    • /
    • 2021
  • This study analyzes the efficient floor layout plan of classrooms for securing evacuation stability in school in case of fire by using the Pathfinder simulation program. Efficient evacuation methods and safety were evaluated by analyzing REST (Required Safe Egress Time) according to the allocation of personnel by floor targeting a high school 5-story building equipped with a ramp and stairs. The current status of personnel assignments exceeded the Required Safe Egress Time(RSET), resulting in a problem with evacuation safety. When students were placed on the 3rd, 4th, and 5th floors, the result was that the time exceeded RSET the most. When students were placed on the 1st, 2nd, and 3rd floors, the result was that they completed evacuation in the shortest time, less than RSET. In the current state, when evacuation was guided by designating an evacuation exit depending on the location, the result of shortening RSET was obtained. As a result, it is effective to put the students on the lower floors when placing students in high-rise school buildings in terms of evacuation safety, and in the preliminary training, it is required to designate evacuation exits so that they can use the nearest exit for each location in case of a fire. As a future research project, additional research is needed on the RSET when a fire occurs in a specific location according to whether the automatic fire door at that location is opened or closed.

Development of technology to predict the impact of urban inundation due to climate change on urban transportation networks (기후변화에 따른 도시침수가 도시교통네트워크에 미치는 영향 예측 기술 개발)

  • Jeung, Se Jin;Hur, Dasom;Kim, Byung Sik
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.1091-1104
    • /
    • 2022
  • Climate change is predicted to increase the frequency and intensity of rainfall worldwide, and the pattern is changing due to inundation damage in urban areas due to rapid urbanization and industrialization. Accordingly, the impact assessment of climate change is mentioned as a very important factor in urban planning, and the World Meteorological Organization (WMO) is emphasizing the need for an impact forecast that considers the social and economic impacts that may arise from meteorological phenomena. In particular, in terms of traffic, the degradation of transport systems due to urban flooding is the most detrimental factor to society and is estimated to be around £100k per hour per major road affected. However, in the case of Korea, even if accurate forecasts and special warnings on the occurrence of meteorological disasters are currently provided, the effects are not properly conveyed. Therefore, in this study, high-resolution analysis and hydrological factors of each area are reflected in order to suggest the depth of flooding of urban floods and to cope with the damage that may affect vehicles, and the degree of flooding caused by rainfall and its effect on vehicle operation are investigated. decided it was necessary. Therefore, the calculation formula of rainfall-immersion depth-vehicle speed is presented using various machine learning techniques rather than simple linear regression. In addition, by applying the climate change scenario to the rainfall-inundation depth-vehicle speed calculation formula, it predicts the flooding of urban rivers during heavy rain, and evaluates possible traffic network disturbances due to road inundation considering the impact of future climate change. We want to develop technology for use in traffic flow planning.

Analysis of the Apparent Specific Gravity for Type-3 Dry Chemical Powder with the Changes in the Internal Pressure of Dry Chemical Extinguisher (분말소화기의 내부압력 변화에 따른 제3종 분말소화약제의 겉보기비중 실험 분석)

  • Ju-Dal, Son;Seo-young, Kim;Ha-sung, Kong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.607-617
    • /
    • 2023
  • This study aims to analyze whether the performance of the fire extinguisher meets the criteria for the apparent specific gravity property test by calculating the change in internal pressure and the use period of the fire extinguisher as a new one with 5 years, recycled one with 5 years, a new one with 10 years, and a new one with 13 years, respectively. As a result of the experiment, when the internal pressure of the fire extinguisher was 0%, the first, second, and third arithmetic mean analysis of the dry chemical extinguisher according to the use period was found to be condemned. When the internal pressure of the fire extinguisher was 50%, it was measured as 130 ml in sample 12-08-new and analyzed as unsuitable. Also, sample 09-09-new of a new dry chemical extinguisher with 13 elapsed years measured 145ml, which was found inappropriate. All other dry chemical extinguishers were analyzed to be suitable. All were noted suitable when having normal internal pressure of the fire extinguisher, except for sample 09-06 of a new dry chemical extinguisher with 13 elapsed years, which was determined to be unsuitable caused by measuring as 131 ml for experimental value. As a result of experiments, some of the apparent specific gravity tests of dry chemical extinguishers from 10 years to 13 years have found that they are unsuitable for the performance of the fire extinguishers due to the massive phenomenon. Accordingly, it is necessary to reduce the endurance period of dry chemical extinguishers from 10 years to 7 years.

Co-incineration Characteristics of Sewage Sludge and Industrial Waste Using the Rotary Kiln Incinerator (로타리킬른 소각로를 이용한 하수슬러지와 사업장폐기물의 혼합소각 특성)

  • Yang, Dong-Jib;Ko, Jae-Cheol;Kim, Jeong-Keun;Park, Hui-Jae;Park, Joon-Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.91-99
    • /
    • 2009
  • This research were performed to evaluate co-incineration characteristics of sewage sludge and industrial waste in rotary kiln incinerator, and provide the fundamental data. Plastic portion (42.55%) in this industrial waste showed over 3 times higher than that (11.92%) of paper. Korean proximate analysis of the waste mixed with sewage sludge and industrial waste (3 : 7, volumetric basis) showed 16.3% of moisture, 70.5% of volatile solids, and 13.2% of ash, respectively. Low heating value of the mixed waste was 4,513kcal/kg. So it was thought that the mixed waste of sewage sludge and industrial waste (containing 43% of plastics and 12% papers) has enough heating value for co-incineration. The incineration of mixed waste showed the lowest SOx and NOx concentrations at $700^{\circ}C$. However, the operation at $950^{\circ}C$ was feasible in considering dioxin and the other hazardous gases. It was concluded that use of $Ca(OH)_2$ should be under investigation for the operation at $950^{\circ}C$.

Mapping Technique for Flood Vulnerable Area Using Surface Runoff Mechanism (지표유출메커니즘을 활용한 홍수취약지구 표출 기법)

  • LEE, Jae-Yeong;HAN, Kun-Yeun;KIM, Hyun-Il
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.181-196
    • /
    • 2019
  • Floods can be caused by a variety of factors, and the main cause of floods is the exceeding of urban drainage system or river capacity. In addition, rainfall frequently occurs that causes large watershed runoff. Since the existing methodology of preparing for flood risk map is based on hydraulic and hydrological modeling, it is difficult to analyse for a large area because it takes a long time due to the extensive data collection and complex analysis process. In order to overcome this problem, this study proposes a methodology of mapping for flood vulnerable area that considered the surface runoff mechanism. This makes it possible to reduce the time and effort required to estimate flood vulnerabilities and enable detailed analysis of large areas. The target area is Seoul, and it was confirmed that flood damage is likely to occur near selected vulnerable areas by verifying using 2×2 confusion matrix and ROC curve. By selecting and prioritizing flood vulnerable areas through the surface runoff mechanism proposed in this study, the establishment of systematic disaster prevention measures and efficient budget allocation will be possible.