• Title/Summary/Keyword: Disaster Prevent System

Search Result 291, Processing Time 0.027 seconds

A Study on Improvement of the police disaster crisis management system (경찰의 재난위기관리 개선에 관한 연구)

  • Chun, Yongtae;Kim, Moonkwi
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.556-569
    • /
    • 2015
  • With about 75% of the population of Korea criticizing the government's disaster policy and a failure to respond to large-scale emergency like the Sewol ferry sinking means that there is a deep distrust in the government. In order to prevent dreadful disasters such as the Sewol ferry sinking, it is important to secure a prime time with respect to disaster safety. Improving crisis management skills and managerial role of police officers who are in close proximity to the people is necessary for the success of disaster management. With disaster management as one of the most essential missions of the police, as a part of a national crisis management, a step by step strengthening of the disaster safety management system of the police is necessary, as below. First, at the prevention phase, law enforcement officers were not injected into for profit large-scale assemblies or events, but in the future the involvement, injection should be based on the level of potential risk, rather than profitability. In the past and now, the priortiy was the priority was on traffic flow, traffic communication, however, the paradigm of traffic policy should be changed to a safety-centered policy. To prevent large-scale accidents, police investigators should root out improper routines and illegal construction subcontracting. The police (intelligence) should strengthen efforts to collect intelligence under the subject of "safety". Second, with respect to the preparatory phase, on a survey of police officers, the result showed that 72% of police officers responded that safety management was not related to the job descriptions of the police. This, along with other results, shows that the awareness of disaster safety must be adopted by, or rather changed in the police urgently. The training in disaster safety education should be strengthened. A network of experts (private, administrative, and police) in safety management should be established to take advantage of private resources with regard to crisis situtions. Third, with respect to the response phase, for rapid first responses to occur, a unified communication network should be established, and a real-time video information network should be adopted by the police and installed in the police situation room. Fourth, during the recovery phase, recovery teams should be injected, added and operated to minimize secondary damage.

Evaluation of Prevention System of Falls and Committing Suicide with Application Technology of Rollinder System (추락 및 투신자살 방지시스템의 조사 및 Rollinder System 적용기술)

  • Park, Sea-Man;Baek, Chung-Hyun;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.591-598
    • /
    • 2019
  • The statistics of committing suicide in S. Korea is ranked in top with serious attempts of falling among OECD countries since 2003. The rates is slightly dropped by 5 percent point, nevertheless the falling is still high for the age of over 10 years old and this matter must be solved. Most of the case of suicides are the falling based on a trend view of falling which is serious matter and cannot be solved easily for both domestic and foreign countries. For example, the steel net of falling prevent was installed in the Golden Gate Bridge costed by 200 million-dollar. In New Zealand, the steel net of falling prevention had been removed and re-installed beccause of the high suicide rates. Canada and Australia also surrounded the bridge with steel fences to prevent suicide without consideration of the beauty of bridge. Therefore, this paper suggested a comparison study on both falling prevention systems in all countries and patent technologies. Also, it covers the blocking skills of approach in both security and limited area. This paper suggested the technical Rollinder system equipped with the mechanical apprentice to prevent effectively the falling sucides and wall passing. Before the installation of Rollinder System by 2016, there were 33 person who tried to fall in the river in Machang Bridge. However, the number of the committing suicides were dramatically reduced to zero after the installation of the system.

Thermal Analysis for Design of Propulsion System Employed in LEO Earth Observation Satellite

  • Han C.Y.;Kim J.S.;Lee K.H.;Rhee S.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.248-250
    • /
    • 2003
  • Thermal analysis is performed to protect the propulsion system of low-earth-orbit earth observation satellite from unwanted thermal disaster like propellant freezing. To implement thermal design adequately, heater powers for the propulsion system estimated through the thermal analysis are decided. Based on those values anticipated herein, the average power for propulsion system becomes 22.02 watts when the only one redundant catalyst bed heater is turned on. When for the preparation of thruster firing, 25.93 watts of the average power is required. All heaters selected for propulsion components operate to prevent propellant freezing meeting the thermal requirements for the propulsion system with the worst-case average voltage, i.e. 25 volts.

  • PDF

Non-Fire Alarm Management and Customized Automatic Guidance System (비화재보 관리 및 맞춤형 자동안내 시스템)

  • Hyo-Seung Lee;Ju-Sang Lee;Woo-Jun Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.355-360
    • /
    • 2023
  • Fire is a disaster that causes irreversible damage to many people due to personal injury and property damage. Various fire detection equipments are installed around us to detect and cope with it quickly. However, due to various problems such as artificial, environmental, and aging, fire detection equipment is activated even though it is not a actual fire, and there are many problems such as delaying the support to the necessary fire scene. In this paper, we analyze the non-fire alarm of the fire detection equipment and propose a system that enables the field staff to check the scene situation through the video as a way to prevent the mobilization due to the misinformation by checking the fire. The purpose of the present invention is to stably cope with a disaster by suggesting a customized automatic guidance system which induces a rapid evacuation by sending an evacuation guidance notification to a range of a fire occurrence neighboring area, and supports a rapid and accurate processing by a rapid dispatch of a firefighter, rather than a wide range of guidance such as an existing emergency disaster guidance letter when it is determined to be an actual fire through the confirmation procedure.

Enactment Direction of Private Investigation Law (민간조사업법 제정방향)

  • Lee, Seung-Chal
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.123-129
    • /
    • 2011
  • The primary agent of civil investigation businesses must be a corporation to line up with public interests, and the government has to carry out the permit system on business owners. As many countries such as those of European and Japan supervise civil investigation business and the police agent supervises guarding businesses, so the police also has to supervise civil investigation business. In many cases, civil investigation businesses deal with private information, and the police has to prevent from infringing customers' basic right by clarifying private information management for punishment. In addition the police has to tighten up customers' obligations. For example the police has to deliver papers about the contents when they enter into or change contract, or after they enter into contract.

Development and Comparison of Data Mining-based Prediction Models of Building Fire Probability

  • Hong, Sung-gwan;Jeong, Seung Ryul
    • Journal of Internet Computing and Services
    • /
    • v.19 no.6
    • /
    • pp.101-112
    • /
    • 2018
  • A lot of manpower and budgets are being used to prevent fires, and only a small portion of the data generated during this process is used for disaster prevention activities. This study develops a prediction model of fire occurrence probability based on data mining in order to more actively use these data for disaster prevention activities. For this purpose, variables for predicting fire occurrence probability of various buildings were selected and data of construction administrative system, national fire information system, and Korea Fire Insurance Association were collected and integrated data set was constructed. After appropriate data cleansing and preprocessing, various data mining methodologies such as artificial neural network, decision trees, SVM, and Naive Bayesian were used to develop a prediction model of the fire occurrence probability of buildings. The most accurate model among the derived models is Linear SVM model which shows 68.42% as experimental data and 63.54% as verification data and it is the best model to predict fire occurrence probability of buildings. As this study develops the prediction model which uses only the set values of the specific ranges, future studies may explore more opportunites to use various setting values not shown in this study.

A Study on the Prevention and Extinguishment of Fire in Vinyl Temporary Buildings for Agriculture and Fishery (농·어업용 Vinyl 가설건축물의 화재 예방 및 진압에 관한 연구)

  • Bong-Woo Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.599-603
    • /
    • 2023
  • Analyzed in the NFDS, The average number of fires in vinyl temporary buildings is more than 1,000 in annually. And the number of deaths and injuries was around 30 people in every year. According to the National Fire Agency, There are 142,386 vinyl temporary buildings for Agriculture and Fishery, of which 4,720 are residential vinyl temporary buildings in illegally. Model house is subject to regulation in fire-related law. But, even though it's the same temporary building, Vinyl temporary building is not subject to regulation. For this reason, Vinyl temporary buildings are left in the blind spot of fire safety. Therefore, In this study, We propose that amend of Act on installation and management of firefighting systems, make of temporary fire safety controller, develop and apply of alarm system that is connected to a single-alarm smoke dretector, organize and operate volunteer fire brigade of the crop group to prevent and extinguish the fire.

The Development of Seismic Monitoring for a Base-Isolated Building System (지진격리 구조물의 지진모니터링 시스템 개발)

  • 김성훈;조대승;박해동;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.247-251
    • /
    • 2001
  • Nowadays, base isolation systems such as lead-rubber bearing, elastomer bearing and sliding bearing have been installed to the various structures to prevent the disaster from seismic. The performance of base isolation system have been well proved by model-scale experiments and numerical analysis. However. the seismic response data measured at real large base-isolated structures is still insufficient. This paper presents a seismic monitoring system, acquiring real-time acceleration signals up to 32 channels, displaying time history and spectrum of the signals, storing the acquired data at a PC hard disk, and replaying the saved data. Moreover, the system can be operated without any limitation for monitoring period by automatic management of stored data file. The developed system has been installed at a real base-isolated building using lead-rubber bearings and we expect its seismic response data with ground motion signal can be well licquired in case of earthquake occurrence.

  • PDF

Recent Trends in the Intelligent Surveillance Technologies (도시철도 지능형 감시시스템에 대한 국외기술 동향 분석)

  • An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.630-635
    • /
    • 2008
  • An urban transit is representative public transportation which lots of people take everyday. Especially, the station of urban transit is one of the very important public civil infrastructures. From the teachings of subway fire disaster occurred at Daegu on 2003, a certain incident might create large numbers of deaths or injuries and a lot of damages to the subway station without having an accurate grasp of emergency situation and doing proper action on the situation. Therefore, the passive surveillance system, which means the present CCTV based system, needs to be changed into the active one. The active surveillance system is the CCTV based system with intelligent softwares which affords to prevent a certain incident or trouble and its aggravation. In this paper, the state of the art of the representative companies developing intelligent softwares and its application sites of Australia and Hong Kong are briefly introduced. Finally, with the consideration of its recent trends, some technical contents for the intelligent surveillance system of domestic urban transit are briefly described.

  • PDF

Fire detection system and alarm system using wild boars (동물들을 이용한 재난 조기 경보 시스템의 설계 및 분석)

  • Jeong, Eui-Jong;Lee, Goo-Yeon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.719-720
    • /
    • 2006
  • Ad hoc networks does not need any wired network infrastructure. Therefore, they have been developed in temporary networks or mainly in military networks. Infostations offer geographically intermittent coverage at high speeds. Up-to-date there have been frequent big forest fires in Korea mountain areas. It is very important to detect them early to prevent them from being big disasters. In this paper, we propose a disaster emergency management system using sensor attached wild boars' mobility combined with infostation system. We also make a numerical analysis of the performance of the system.

  • PDF