• Title/Summary/Keyword: Disaster Management Performance

Search Result 277, Processing Time 0.026 seconds

A Study on the False Alarm Management of Alarm Monitoring Service (기계경비의 오경보 관리방안)

  • Chung, Tae-Hwang
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.93-99
    • /
    • 2012
  • This study is to present false alarm management of alarm monitoring service, by literature analysis and interview with the persons in charge of service of alarm monitoring service companies. To reduce false alarm by customer's mistake, development of educational tool that could provide practical effect is needed. Also institutional consent to charge a specific sum of money could be considered for unnecessary dispatch that occurred by customer's mistake. To improve the false alarm by defect of equipments and installation of electronic security system, standardization of technical regulation and system installation is necessary. And to improve the performance of passive infrared sensor that cause most false alarm, the development of new type of sensor is required. It could be considered that guideline on educational contents and term definition about false alarm could be come under the security regulation.

A Study on the Improvement of Field Activity for Firemen in Sandwich Panel Warehouse (샌드위치패널 창고 소방대원 현장활동 대응력 제고 방안)

  • An, Byung-Kug;Kim, Woon-Hyung;Yang, So-Jin;Ham, En-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.421-429
    • /
    • 2020
  • Purpose: The purpose of this study is to present step-by-step countermeasures to prevent fires in sandwich panel warehouses and to enhance on-site fire response capabilities. Method: Interviews of firefighters related to fire sites, advice from fire experts, and experiments on protection performance were conducted to draw up measures for each element to strengthen on-site response capabilities. Result: The fire safety management checklist for warehouse fire safety managers and the installation standards for wall protection of sandwich panel warehouses are presented. In addition, Standard Operational Procedures(SOP) for fire application of sandwich panel warehouses were established for firefighters on-site. Conclusion: Through this study, step-by-step fire safety measures were established for preventing, protecting and suppressing fires in sandwich panel warehouses.

Safety Measure Developed Through Analysis of Firefighters' 『Investigation Report on Accidents to On-Site Workers』

  • Jo, Chang-Hyun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.334-344
    • /
    • 2021
  • The study has suggested a way to minimize safety accidents found in on-site firefighting activity by analyzing firefighters' [investigation report on accidents to on-sie workers]. The study result is described as follows. First, the result of [investigation report on on-site workers] shows that while accidents are found to most frequently have occurred to low-ranking firefighting officers such as Sobangsa and Sobanggyo and firefighting officers with career of less than 5 years, fire-extinguishing activity proved to be the most prone to accidents in the category of activity. Second, analysis performed to identify variance between injury extent and area based on cause of accident shows statistically significant variance. In addition, the result of verifying difference in cause of accident based on category of activity shows significant difference with 'falling over and sliding' being the highly likely cause of accident in fire containment and rescue activities and 'reckless move' being highly likely case of accident in emergency activities. Third, the result of verifying factors behind the extent of injury done to on-site workers shows that when accident is caused by 'incomplete behavior', it was found that the extent of injury is substantial. It was also found that rescue activity is accompanied by substantial extent of injury. As a solution to this, the study suggested ways to establish, extend and operate safety-specific curriculum for entrants, develop materials regarding risk prognosis training and explicate training-related regulations, set up safety management measure for a single squad team, upgrade performance of private protection equipment, institutionalize SOP by on-site activity stage, materialize and activate swift rescue team and increase objectivity and proficiency of safety accident investigation.

Analysis of Waterproof Time by Number of Twists between Ordinary Fire Hose and Anti-twist Fire Hose (일반 소방호스와 꼬임방지 소방호스의 꼬임 횟수에 따른 방수시간 분석)

  • Hong, Suk-Hwan;Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.55-60
    • /
    • 2021
  • This study is to check waterproof by number of twists of fire hose and measure the first waterproof time to analyze the relationship between twists of fire hose and first waterproof time and waterproof by position of twists so as to suggest the efficient plan to prevent twists of fire hose. Ordinary fire hose did not make waterproof in case that position of twists was near the nozzle with twists 5 times or more, while anti-twist fire hose had no problem for waterproof only with delayed time. Like ordinary fire hose, anti-twist fire hose also showed the tendency to increase the waterproof time in proportion to the number of twists. In case that the position of twists was near waterproof port even with 10 times of twists in anti-twist fire hose, the first waterproof time was increase by 0.63 seconds on average without any problem for waterproof, which was somewhat faster than that in ordinary fire hose. With respect to the position of twists, waterproof of anti-twist fire hose was affected more as the number of twists was increased more near the nozzle rather than near the waterproof port, like ordinary fire hose. In summary, anti-twist fire hose equipped with anti-twist tool at the middle connection port and the nozzle showed a good waterproof performance with delayed waterproof time regardless of number of twists, as a solution for the twist problem of ordinary fire hose.

A Prototype of Distributed Simulation for Facility Restoration Operation Analysis through Incorporation of Immediate Damage Assessment

  • Hwang, Sungjoo;Choi, MinJi;Starbuck, Richmond;Lee, SangHyun;Park, Moonseo
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.339-343
    • /
    • 2015
  • To rapidly recover ceased functionality of a facility after a catastrophic seismic event, critical decisions on facility repair works are made within a limited period of time. However, prolonged damage assessment of facilities, due to massive damage in the surrounding region and the complicated damage judgment procedures, may impede restoration planning. To assist reliable structural damage estimation without a deep knowledge and rapid interactive analysis among facility damage and restoration operations during the approximate restoration project planning phase, we developed a prototype of distributed facility restoration simulations through the use of high-level architecture (HLA) (IEEE 1516). The simulation prototype, in which three different simulations (including a seismic data retrieval technique, a structural response simulator, and a restoration simulation module) interact with each other, enables immediate damage estimation by promptly detecting earthquake intensity and the restoration operation analysis according to estimated damage. By conducting case simulations and experiments, research outcomes provide key insights into post-disaster restoration planning, including the extent to which facility damage varies according to disaster severity, facility location, and structures. Additional insights arise regarding the extent to which different facility damage patterns impact a project's performance, especially when facility damage is hard to estimate by observation. In particular, an understanding of required type and amount of repair activities (e.g., demolition works, structural reinforcement, frame installation, or finishing works) is expected to support project managers in approximate work scheduling or resource procurement plans.

  • PDF

A Novel on Optimal Growth Management System of Corp using Recirculation of Nutrient Solution based on IoT and Location Tracking Technology (IoT 및 위치 추적 기술 기반의 양액 순환 방식을 활용한 작물의 최적 생장 관리 시스템에 관한 연구)

  • Jung, Se Hoon;Park, Sung Kyun;Sim, Chun Bo
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.11
    • /
    • pp.1891-1899
    • /
    • 2016
  • Recently food problem and crop disaster have been increased continuously because of the meteorological changes. These cause rising cost for crops continuously and irregularly. Some researchers have studied straight structure of device for hydroponics and plant factory previously to solve a fundamental part of these problems. However, there are several problems such as limited crop cultivation space, providing irregular nutrients for crops, and lack of monitoring interfaces. For them, we propose an optimal growth and development crops management system using light source tracking and recirculation of nutrient solution method to supply nutrient continuously based on IoT. In order to evaluate the performance of our system, we compared and analyzed in terms of two viewpoints, the tracking analysis for natural light source measurement and the growth of crops through artificial light, LED, respectively. We confirmed that the higher the duty ratio of LED, the larger the crop's size, particularly. As well as, for about 1 month, we compared with the existing natural light growing environment and that of our system. It was confirmed that the size of the crops grown through our system is about three times larger than that of natural light natural crops.

Construction of Earthquake Disaster Management System Based on Seismic Performance Evaluation of Architectural Structure (건축물 내진성능평가에 의한 지진재해관리정보체계 구축)

  • Kim, Seong-Sam;Cho, Eun-Rae;Yoon, Jeong-Bae;Yoo, Hwan-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.59-67
    • /
    • 2007
  • This paper proposes potentialities of constructing the information system for earthquake hazard management which can manage and analyse earthquake risk and hazard systematically. The experimental results as well as architectural structure investment data for seismicity assessment are built in database and connected with GIS for assessing earthquake safety of building in urban area. For earthquake-resistant performance assessment, we collected and classified building structural data according to assessment criteria using building register, architectural map, digital map, and then complemented database with field survey data. We also suggest GIS-based information system can cope with and manage earthquake hazard effectively, as evaluating earthquake risk by performing detailed earthquake-resistant assessment and determining final assessment scores. The assessment should be processed quickly and accurately by integrating the earthquake hazard information management system with modularization of assessment procedure and method in the future.

  • PDF

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

A study on the effect of gusty wind on smoke control performance in road tunnel (돌풍이 도로터널의 제연성능에 미치는 영향 연구)

  • Baek, Doo-San;Cho, Hyeon-Seok;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.95-108
    • /
    • 2022
  • The increase in the use time of tunnel users due to the lengthening of the road tunnel may increase the evacuation time in case of fire, resulting in a large number of casualties. In order to reduce the casualties caused by fire, the "Road Tunnel Design Manual, Part 6 Tunnel" and "Road Tunnel Disaster Prevention Facility Installation and Management Guidelines" stipulate that ventilation facilities should be installed along with the extension of the tunnel. The ventilation system design factor considers the wind speed of the external natural wind to be at least 2.5 m/s, and it is applied upward according to the characteristics of the tunnel. As a result of analyzing the five-minute average wind speed data in the Daegwallyeong region for the past 6 years, it was analyzed that 15.8% of the windy days were winds of 10 m/s or more, and the maximum was 20 m/s. Therefore, in this study, when a fire occurs in a tunnel, the pattern of natural wind flowing into the tunnel and the backlayering distance of the tunnel fire smoke according to the maximum wind speed were analyzed. As a result, it was analyzed that a backflow of up to 490 m occurs when a gust of 20 m/s blows.

A Basic Study on the Performance Improvement of Safety Certification Standards (안전인증기준 성능화에 대한 기반 연구)

  • Byeon, Jung-Hwan;Kim, Jung-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.487-499
    • /
    • 2021
  • Purpose:The purpose of the paper is to review the problems of performance enhancement of safety certification standards and to suggest directions for improvement in order to rationalize safety certification standards for future industrial development and environmental changes. Method: The problems and limitations of the safety certification system are summarized through literature review and interview with manager, and the status of safety certification standards is classified into design standards, performance standards, and detailed standards, and the status analysis is performed. In addition, by synthesizing the results of the investigation and analysis, improvements are suggested to improve the performance of the safety certification standards. Result: Through the survey, the problems and limitations of safety certification could be grouped into six categories: government-led certification system operation, standardized certification standards, long time required to improve certification, poor certification standards preparation system, and lack of reflection of industry opinions. And, as a result of analyzing the certification standards by dividing them into performance and design standards, in the case of machinery, equipment, and protection devices, the design standards were high at 69.7% and 64.9%, whereas in the case of protective equipment, the performance standards were high at 61.1%. In order to improve the performance of safety certification standards centered on design standards, it is necessary to determine the possibility of performance enhancement of the certification standards and determine the feasibility of the inspection test method. In order to improve performance, it was reviewed that it was necessary to establish a systemic foundation and infrastructure, such as strengthening the Product Liability Act, systematizing market monitoring, etc., distributing certification test tasks, and participating in the preparation of certification standards by the private sector. Conclusion: Through this study, the problems and limitations of Korea's safety certification system were summarized and the necessity for performance improvement was reviewed. Performance improvement of safety certification standards is a matter that requires preparatory work, such as legislative revision and infrastructure construction, and requires mid-to-long-term promotion. In addition, rather than improving the overall safety certification standards, the performance requirements for each item subject to certification should be reviewed and promoted, and details should be specified through additional research.