• Title/Summary/Keyword: Disaster Case

Search Result 1,289, Processing Time 0.029 seconds

G-RAID: A Green RAID Mechanism for enhancing Energy-Efficiency in Massive Storage System (G-RAID: 대용량 저장장치에서 에너지 효율향상을 위한 그린 RAID 기법)

  • Kim, Young-Hwan;Suck, Jin-Sun;Park, Chang-Won;Hong, Ji-Man
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.6
    • /
    • pp.21-30
    • /
    • 2011
  • In the global IT market, a lot of issues for responding to various environmental regulations emerged. In case of the data centers, it is consuming huge amounts of energy to maintain. So there have been various technical attempts as Consolidation, Virtualization, Optimization to efficiently manage energy and data storage to fix the problems. In this paper, we propose a new RAID(Redundant Array of Independent Disks) mechanism which is differing the intensity of power consumption and works to provide data protection and disaster recovery(backup, mirroring etc.) to stratify multiple volumes. G-RAID minimize the power consumption and the lower of I/O performance by selecting the volume depending on the frequency of data access while classifying the power consumption between volumes in storage system. Also, it is possible that a filesystem and block map information of G-RAID is processed by basic unit which is group located in a row for the blocks to work efficiently and can minimize the performance degradation of block mapping load by the access frequency in each groups. As a result, we obtained to elevate a little bit of response time caused by block relocation work, but showed the decrease of power consumption by 38%.

A 3D ground penetrating radar imaging of the heavy rainfall-induced deformation around a river levee: a case study of Ara River, Saitama, Japan (폭우에 의해 발생된 강 제방 주변 변형의 3차원 GPR 영상화: 일본 사이타마현의 아라강에 대한 현장적용사례)

  • Yokota, Toshiyuki;Inazaki, Tomio;Shinagawa, Shunsuke;Ueda, Takumi
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • This paper describes a three-dimensional ground penetrating radar (GPR) survey carried out around a levee of the Ara River in Saitama, Japan, where deformation of the ground was observed after heavy rainfall associated with the typhoon of September 2007. The high-density 3D GPR survey was conducted as a series of closely adjacent four directional sets of 2D surveys at an area surrounding vertical cracks on the paved road caused by deformations induced by heavy rain. The survey directions of the 2D surveys were 0, 90, 45, and -45 degrees with respect to the paved road and the intervals between lines were less than 0.5 m. The 3D subsurface structure was accurately imaged by the result of data processing using Kirchhoff-type 3D migration. As a result, locations and vertical continuities of the heavy rainfall induced cracks in the paved road were clearly imaged. This will be a great help in considering the generation mechanisms of the cracks. Moreover, the current risk of a secondary disaster was found to be low, as no air-filled cavities were detected by the 3D GPR survey.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

A Proposal on Evacuation Safety in Medical Welfare Facilities for the Elderly: Targeting the Goyang City (노인의료복지시설의 피난안전에 대한 제언: 고양시를 대상으로)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.52-58
    • /
    • 2020
  • The number of medical welfare facilities caring for the elderly with paralysis and dementia has been increasing rapidly because of the change in the way of supporting the elderly, stemming from an increase in the number of the elderly and working couples. These medical welfare facilities are usually installed all over the city and are gradually becoming high-rise. Few inmates are capable of making their own decisions in case of fire at night and when there are no escape routes such as ramps for evacuation, leading to massive casualties. This study aimed to identify problems in evacuation in the medical welfare facilities for the elderly in Goyang city. This city has the largest number of medical welfare facilities for the elderly per unit area. The following strategies could aid in better evacuation: secure ramps or bed escape elevators; the bedrooms of the inmates should have one-hour fire resistance; the stairs should have the structure of an enclosed stairway; the necessary apparatus for evacuation, such as an escape chute, should be installed; and, to conclude, a business agreement with neighboring agencies to help inmates escape during the fire. The state should implement necessary measures to protect the lives and property of the people. Rapid implementation of this proposal is necessary for the evacuation safety of an increasing number of medical welfare facilities for the elderly.

Modeling Three-dimensional Free Surface Flow around Thin Wall Incorporation Hydrodynamic Pressure on δ-coordinate (δ-좌표계에서 동수압 계산 수중벽체 인근흐름 수치모형실험)

  • Kim, Hyo-Seob;Yoo, Ho-Jun;Jin, Jae-Yul;Jang, Chang-Hwan;Lee, Jung-Su;Baek, Seung-Won
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.327-336
    • /
    • 2014
  • Submerged thin walls are extreme case of submerged rectangular blocks, and could be used for many purposes in rivers or coastal zones, e.g. to tsunami. To understand flow characteristics including flow and pressure fields around a specific submerged thin wall a numerical model was applied which includes computation of hydrodynamic pressure on ${\sigma}$-coordinate. ${\sigma}$-coordinate has strong merits for simulation of subcritical flow over mild-sloped beds. On the other hand ${\sigma}$-coordinate is quite poor to treat sharp structures on the bed. There have been a few trials to incorporate dynamic pressure in ${\sigma}$-coordinate by some researchers. One of the previous approaches includes process of sloving the Poisson equation. However, the above method includes many high-order terms, and requires long cpu for simulation. Another method SOLA was developed by Hirt et al. for computation of dynamic pressure, but it was valid for straight grid system only. Previous SOLA was modified for ${\sigma}$-coordinate for the present purpose and was adopted in a model system, CST3D. Computed flow field shows reasonable behaviour including vorticity is much stronger than the upstream and downstream of the structure. The model was verified to laboratory experiments at a 2DV flume. Time-average flow vectors were measured by using one-dimensional electro-magnetic velocimeter. Computed flow field agrees well with the measured flow field within 10 % error from the speed point of view at 5 profiles. It is thought that the modified SOLA scheme is useful for ${\sigma}$-coordinate system.

Analysis on Characteristics of Orographic Effect about the Rainfall Using Radar Data: A Case Study on Chungju Dam Basin (레이더 자료를 이용한 호우의 산지효과 특성 분석: 충주댐 유역을 대상으로)

  • Ku, Jung Mo;Ro, Yonghun;Kim, Kyoungjun;Yoo, Chulsang
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.393-407
    • /
    • 2015
  • This study analyzed the characteristics of orographic effect using radar data for the Chungju dam basin. First, independent rainfall events were selected by applying the IETD (Interevent Time Definition) and rainfall threshold. Among those independent rainfall events, rather strong events were selected to decide the occurrence condition of orographic effect. Also, the average reflectivity was calculated for the entire period and for the period of storm center, and the change in reflectivity was analyzed by comparing the average reflectivity to that in the mountain area. Important rainfall factors were selected and applied to the logistic regression model to decide the occurrence condition of orographic effect. Summarizing the results is as follows. First, evaluation of the radar data along the passing line of a storm showed the increase of radar reflectivity in the mountain area. Second, the result of logistic regression analysis showed that the orographic effect in the Chungju Dam Basin mostly occurred when the rainfall intensity was higher than 4 mm/hr, the storm velocity was lower than 4 km/hr, and the approach angle was $90^{\circ}{\pm}5^{\circ}$.

Sensitivity analysis of pump and tank sizes on water network operation and water age (송수펌프용량 및 배수지규모에 따른 송·배수시스템의 운영비용 및 체류시간 분석)

  • Kim, Kangmin;Choi, Jeongwook;Jung, Donghwi;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.803-813
    • /
    • 2017
  • Recently, various studies have been conducted to optimize the pump operation scheduling and/or the pump/tank size minimizing the system cost of water distribution network. Prior to that, it is important to understand the sensitivity of pump/tank size on the system cost and overall water quality. Here, we have performed the sensitivity analysis to investigate the effect of pump/tank size on the economic cost (construction and operation) and water quality (water age). The analysis was applied on a real, large-scale water transmission network currently operating in South Korea. The results revealed that the pump/tank size has a strong influence on system construction/operation costs. Especially, the tank size has a significant effect on the system-wide water quality. In the case of applied networks, the operating cost decreases as the capacity of the facility increases, but the design cost increases. Using a sensitivity analysis, a suitable range of pump/tank size could be suggested to minimize costs and stabilize the water quality at the same time prior to a system design.

Rearranging Emergency Medical Service Region Using GIS Network Analysis - Daejeon Metropolitan City Case Study (GIS 네트워크 분석을 활용한 응급의료서비스 권역 재조정 방안 - 대전광역시 사례 연구)

  • Kwon, Pil;Lee, Young Min;Huh, Yong;Yu, Ki Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.3
    • /
    • pp.11-21
    • /
    • 2015
  • Emergency Medical Service(EMS) has become focused due to all kinds of disaster and a great number of casualties. The 119 emergency vehicles' dispatching methods are now being focused, for travel time of ambulances are the critical components in terms of saving human lives. Therefore, this study tried to rearrange 119 EMS regions more efficiently. For this study, Daejeon Metropolitan City's real call cases were analyzed. In order to rearrange the regions, OD Cost Matrix analysis was performed between 800 thousands random points and 26 departments in the Daejoen Metropolitan City. By creating Thiessen Polygon from the random points, a new region was created. As a results, average areas of the regions were reduces from 32 square kilometers to 20 square kilometers, and average time of arrivals are were also improved. Hence, if related organizations plan to rearrange EMS regions, they may utilize this study.

The Practical Suggestion for the Production of Educational Animation for Prevention of Safety Accidents (안전사고 예방을 위한 교육용 애니메이션 제작에 대한 실천적 제안)

  • Lee, Hyun-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.6
    • /
    • pp.169-179
    • /
    • 2018
  • The Korean society has become increasingly concerned about the safety consciousness because of the Sewol Ferry disaster in April 2014. This shows the absence of social system and safety consciousness of Korean society that has been rapidly growing through fast industrialization. The purpose of this paper is to suggest guidelines for the production of a safety animation by approaching the discourse of public value. For this research process, first, literature review will be conducted by focusing on the safety culture, causes of safety accidents, safety education and educational effect using animation. Second, I will analyze 11 safety animation films by focusing on (1) construction of accident environment(narrative, character and background design) (2) exploration of dangerous elements and accident happening(accident type and dangerous elements, method of direction for accident happening, damage degree) (3) the guideline for safety behaviour. Third, guidelines for the production of safety animation will be suggested by analyzing the results of literature reviews and case studies in a comprehensive way. It is expected that this paper will be used as a basic data for academic research and animation production related to the safety accident.

An Analysis of Characteristic Parameters for the Design of Detention Pond in Urbanized Area (도시유역에서 저류지 설계를 위한 특성인자 분석)

  • Lee, Jae-Joon;Kim, Ho-Nyun;Kwak, Chang-Jae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.37-47
    • /
    • 2006
  • Urban development results in increased runoff volume and flowrates and shortening in time of concentration, which may cause frequent flooding downstream. Flow retardation structures to limit adverse downstream effects of urban storm runoff are used. There are various types of flow retardation measures include detention basins, retention basins, and infiltration basins. In basic planning phase, a number of planning models of detention ponds which decide storage volume by putting main variables were used to design detention ponds. The characteristics of hydrological parameters $\alpha,\;\gamma$ which are used in planning models of detention pond were analyzed. In this study, detention ponds data of Disaster Impact Assessment report at 22 sites were analyzed in order to investigate correlation between characteristic of urban drainage basin parameter and characteristics of detention pond parameter due to urbanization effects. The results showed that storage volume was influenced by peak discharge ratio $\alpha$ more than runoff coefficient ratio $\beta$ and peak discharge ratio $\alpha$ was influenced by runoff coefficient ratio $\beta$ less than regional parameter n. Storage ratio was mainly influenced by duration of design rainfall in the case of trapezoidal inflow hydrograph such as Donahue et al. method.