• Title/Summary/Keyword: Direction of rotation

Search Result 697, Processing Time 0.023 seconds

주형의 회전이 Al-Cu 합금의 응고과정에 미치는 영향 (The effect of mold rotation on solidification process of an Al-Cu alloy)

  • 유호선
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.525-540
    • /
    • 1997
  • The effect of mold rotation on the transport process and resultant macrosegregation pattern during solidification of an Al-Cu alloy contained in a vertical axisymmetric annular mold cooled from the inner wall is numerically investigated. The mold initially at rest starts to rotate at a prescribed angular velocity simultaneously with the beginning of cooling. Computed results for a representative case show that the mold rotation essentially suppresses the development of both thermal and solutal convections in the melt, creating distinct characteristics such as the liquidus front, flow pattern and temperature distribution from those for the stationary mold. Thermal convection which develops at the early stages of cooling is soon extinguished by the rotating flow induced during spin-up, and thus does not effectively remove the initial superheat from the melt. On the other hand, solutal convection, though it weakens considerably and is confined within the mushy zone, still predominates over the solute redistribution process. With increasing the angular velocity, the solute transport in the axial direction is enhanced, whereas that in the radial direction is reduced. The final macrosegregation formed in the mold rotating at moderate angular velocities appears to be favorable in comparison with the stationary casting, in that not only relatively homogenized composition is achieved, but also a severely positive-segregated channel is restrained.

용접 조건이 Al-7075-T651의 마찰교반용접부의 인장 특성에 미치는 영향 (Effect of Welding Condition on Tensile Properties of Friction Stir Welded Joints of Al-7075-T651 Plate)

  • 김치옥;김선진
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.61-68
    • /
    • 2011
  • This paper investigates the tensile properties of the friction stir welded joints of Al 7075-T651 aluminum plate according to the welding conditions. A 7075-T651 aluminum alloy plate with a thickness of 6.0 mm was used in this investigation. For the friction stir welding (FSW) process, a tool with shoulder diameter of 20 mm and probe diameter of 9 mm was used. The rotation speed and traverse speed conditions were changed in this study, the other welding conditions are constant. The welding direction was aligned with the material rolling direction, and dimension of the FSW plate were $250{\times}100{\times}6\;mm$. As far as this work is concerned, the optimal FSW conditions are determined as the rotation speed, 600 rpm and traverse speed 0.8 mm/sec or the rotation speed, 800 rpm and traverse speed 0.5 mm/sec.

XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

OFDM 수신기의 CORDIC 기반 주파수 동기를 위한 선형적인 위상 표현 방법 (Phase Representation with Linearity for CORDIC based Frequency Synchronization in OFDM Receivers)

  • 김시현
    • 대한전자공학회논문지SP
    • /
    • 제47권3호
    • /
    • pp.81-86
    • /
    • 2010
  • CORDIC (COordinate Rotation DIgital Computer) 은 간단한 하드웨어로 벡터의 위상으로의 변환이나 회전 등의 위상 연산을 할 수 있으므로 OFDM 수신 시스템에서의 주파수 동기부를 설계할 때 효과적으로 사용될 수 있다. 그러나 CORDIC 알고리듬에서 위상을 표현하는 방향 시퀀스 (direction sequence, DS) 가 선형적이지 않기 때문에 사용상의 많은 제약이 존재한다. 본 논문에서는 근사적 선형성을 지닌 LBDS (linearized binary direction sequence) 표현 방법을 제안하고, LBDS의 최대 위상오차에 대해 분석한다. 또한 DS로부터 LBDS로 변환하는 하드웨어와 그 역변환 하드웨어의 구조를 제안한다. LBDS를 채택하면 위상 추정, 주파수 오차 루프 필터링, 위상 보정 역회전 등 주파수 동기의 전 과정에 CORDIC과 일반적인 산술 연산기를 사용할 수 있다. T-DMB 복조기에 사용될 수 있는 22비트 LBDS에 대한 예도 기술된다.

광대역 신호 처리에서의 도래각 추정 : Rotation of Signal Subspaces 방법 (Direction-of-Arrival Estimation in Broadband Signal Processing : Rotation of Signal Subspace Approach)

  • 김영수
    • 대한전자공학회논문지
    • /
    • 제26권7호
    • /
    • pp.166-175
    • /
    • 1989
  • 본 논문은 rotation of subspaces 개념을 이용한 도래각 추정 방법을 제시한다. 이 방법은 여러 응용분야에서 대두되는 부공간들(subspaces)의 각도 및 거리와 밀접한 관련이 있다. 먼저 최소 자승을 이용하여 한 부공간을 다른 부공간으로 변환 시켜주는 최적 변환 행렬을 구하기 위한 효율적인 방법을 유도하고 이를 이용하여 다중 광대역 신호들 (인코히어런트, 부분적인 코히어런트와 완전한 코히어런트의 혼합신호들)의 도래각을 추정한다. 대표적인 응용으로, 잡음의 배열 스펙트럼 밀도 행렬이 변하지 않는 액티브 시스템(e. g. sonar system) 경우에 성능을 높이기 위하여 효율적인 ROSS (rotation of signal subspaces) 알고리듬을 제안한다. ROSS 알고리듬은 Wang-Kaveh's CSS-focusing 방법에서 사용하는 예비처리와 공간 필터링을 필요로 하지 않는 장점이 있으며 일반적인 모든 배열 안테나에도 적용될 수 있다. 시뮬레이션 결과, 제안된 새로운 알고리듬이 CSS-focusing 방법 및 Forward-Backward Spatial Smoothed MUSIC 보다 높은 성능을 가짐을 알 수 있었다.

  • PDF

K0-압밀점토(壓密粘土)의 주응력회전(主應力回轉) 효과(効果) (The Effects of Principal Stress Rotation in K0-Consolidated Clay)

  • 홍원표
    • 대한토목학회논문집
    • /
    • 제8권1호
    • /
    • pp.159-164
    • /
    • 1988
  • 연직하중(鉛直荷重), 구속압(拘束壓) 및 torque를 각각 독립적으로 작용시킬 수 있는 비틀림전단시험(剪斷試驗)을 실시하여 주응력축(主應力軸)을 회전(回轉)시켰을 경우, 변형율증분방향(變形率增分方向)과 응력방향(應力方向) 혹은 응력증분방향(應力增分方向) 사이의 관계가 조사되었다. 이 비틀림전단시험(剪斷試驗)은 $K_0$-압밀점토시료(壓密粘土試料)에 대하여 비배수(非排水) 및 배수(排水) 상태하에서 주응력축회전(主應力軸回轉)이 가능한 전 응력경로(應力徑路)로 실시되었다. 본(本) 연구(硏究)결과 파괴시의 변형율증분(變形率增分)벡터의 방향은 응력(應力)벡터방향과 일치함을 알 수 있었다. 즉 변형율증분(變形率增分)벡터방향은 초기의 낮은 응력단계(應力段階)에서는 응력증분(應力增分)벡터 방향과 일치하지만 높은 응력단계(應力段階)에서는 응력(應力)벡터방향과 일치하게 된다. 이는 점토(粘土)의 거동(擧動)이 응력의 증가에 따라 탄성(彈性)에서 소성(塑性)으로 변천되어 감을 의미한다. 따라서 주응력축회전(主應力軸回轉)시의 점토거동(粘土擧動)의 구성식화(構成式化)에는 탄소성이론(彈塑性理論)의 적용이 가능함이 입증되었다.

  • PDF

말단 장치의 평면 유지가 가능한 로봇 회전 암의 설계 (Design of Robot Rotation Arm with Parallel Motion in End Effector)

  • 이종신
    • 로봇학회논문지
    • /
    • 제5권4호
    • /
    • pp.359-366
    • /
    • 2010
  • This study proposes the design method for the robot rotation arm which the end effector that is connected in end of the arm keeps parallel motion even though the robot arm rotates. So far, most robot arm rotates together the end effector when the arm rotates. For this, this study proposes the mechanism that the arm is linked to each 4 parallel link so that rotation is possible by 4 pins, and the rotation arm connects 2 joints of diagonal line direction to a link in each 4 joint for rotation, and designs so that can change length of the link. For verification of design, this study targeted that develop the rotation arm for medical examination that use in ophthalmology. It is important that a medical robot offers comport to patient and design compactly so that medical examination and treatment space may can be defined enough. It is designed so that all drive elements may be positioned on interior of the arm and optimization of design for main parts was carried out in this study for this. The robot arm which is developed in this study manufactured to use by medical phoropter arm, and got good result by an experiment. The robot rotation arm which is proposed in this study is judged to contribute very effectively in case use of a medical robot arm for medical examination and treatment, also the robot arm which the end effector that is connected in the end of the arm needs to keep parallel motion. And, the robot arm which is developed in this study made an application as license.

간단한 얼굴 방향성 검출방법 (A Simple Way to Find Face Direction)

  • 박지숙;엄성용;조현희;정민교
    • 한국멀티미디어학회논문지
    • /
    • 제9권2호
    • /
    • pp.234-243
    • /
    • 2006
  • 최근 급속한 HCI(Human-Computer Interaction) 및 감시 기술의 발달로, 얼굴영상을 처리하는 다양한 시스템들에 대한 관심이 높아지고 있다. 그러나 이런 얼굴영상을 처리하는 시스템들에 대한 연구는 주로 얼굴인식이나 얼굴 표정분석과 같은 분야에 집중되었고, 얼굴의 방향성 검출과 같은 분야에는 많은 연구가 수행되지 못하였다. 본 논문은 두 눈썹과 아래 입술로 구성된 얼굴삼각형(Facial Triangle)이라는 특징을 이용하여 얼굴의 방향성을 쉽게 측정하는 방법을 제안한다. 특히, 하나의 이미지만을 사용하여 얼굴의 수평 회전각과 수직 회전각을 구하는 간단한 공식을 소개한다. 수평회전각은 좌 우 얼굴삼각형간의 면적비율을 이용하여 계산하고, 수직회전각은 얼굴삼각형의 밑변과 높이 비율을 이용하여 계산한다. 실험을 통해, 제안하는 방법은 오차범위 ${\pm}1.68^{\circ}$ 내에서 수평회전각을 구할 수 있었고, 수직회전각은 회전각이 증가할수록 오류가 줄어드는 경향을 보여주었다.

  • PDF

유도 양팔업어치기 패턴에 따른 공격팔 기울이기 동작의 운동학적 분석 (A kinematic analysis of the attacking-arm-kuzushi motion as to pattern of morote-seoinage in judo)

  • 김의환;윤현
    • 한국운동역학회지
    • /
    • 제13권1호
    • /
    • pp.73-94
    • /
    • 2003
  • The purpose of this investigation was to analyze A kinematic analysis of the Kuzushi-arm motion when performing Morote-Seoinage in judo who was 5 females university representative judokas of light weight category in judo, and filmed on video cameras(60field/s). The data of this study digitizied by KWON3D 2.1 program computed the average and standard deviation calculated individual 5 trials with Programing Lab view 6i. From the data analysis & discussion, the following conclusions were drawn : 1) distance variable of attacking hand arm in kuzushi motion Left right(X direction) displacement variable was all of A, B, C pattern with moving left to right and leaning. Strip of displacement variable was ordo. to C(55.6cm), A(53.3cm), B(43.9cm) pattern, C pattern largely leaned to left Front Rear(Y direction) displacement variable was different A($131.3cm{\pm}3.1cm$), B($128.7{\pm}4.0cm$) and C(111.0cm) on ready position, 3 pattern leaned to rear direction. Strip of displacement was order to B(43.4cm), A(41.1cm) and C pattern(28.3cm). Up down(Z direction) displacement variable was all of A, B, C pattern leaned to up in the Kuzushi-phase and leaned to down in the Kake-phase. Strip of displacement was order to A(83.9cm), B(80.4cm), C pattern(71.9cm). 2) Shoulder joint angle variable Flexion and extension Ready position' angle was A($138.3{\pm}4.9^{\circ}$), B($142.9{\pm}3.7^{\circ}$) and C($164.5^{\circ}$) pattern, strip of flexion extension was order to C($80.9^{\circ}$), A($79.9^{\circ}$) and B($39.0^{\circ}$) pattern, greatly C pattern had largely angle change. Adduction and abduction : B and C pattern's angle change were adduction and abduction in the Kuzushi-phase after adduction in the Kake phase, A pattern's angle change was abduction in the Kuzushi-phase after adduction in the Kake phase. internal and external rotation : 3 pattern were internal rotation in the Tsukuri phase and external rotation in the Kake phase. After B and C pattern were external rotation and A pattern was internal rotation. 3) Elbow joint angle variable Flexion and extension 3 pattern's ready position angle were A($142.0{\pm}4.4^{\circ}$), B($123.5{\pm}5.5^{\circ}$) and C($105.5^{\circ}$) and flexion. Strip of flexion extension were order to A($57.9^{\circ}$), C($34.6^{\circ}$) and B($25.2^{\circ}$) pattern.

계단 오르기 시 정강이뼈 돌림이 하지의 역학과 근 활성도에 미치는 영향 (Tibial Rotation Influences Muscle Activity and Motion of Lower Extremity during The Stair Ascent)

  • 강정일;이유경;박승규;이준희;양대중;최현
    • 한국운동역학회지
    • /
    • 제21권4호
    • /
    • pp.467-477
    • /
    • 2011
  • This study was performed to investigate the effects of tibial rotation while going up stair on muscle activity of vastus medialis oblique and vastus lateralis, and on patellar displacement. The subjects included 30 people (male: 15; female: 15) who were randomly assigned to the tibial internal-rotation, neutral-rotation, and external-rotation groups. The subjects went up the stair while performing the assigned rotations, and the rotation of the hip and the displacement of the patella were measured using a 3D motion analyzer. In addition, the maximum voluntary isometric contraction (MVIC) of the vastus medialis oblique and vastus lateralis were measured using surface electromyogram. On the tibial internal rotation, the hip rotation significantly appeared in the same direction and so did on the tibial neutral and external rotations(p<.001). Although the MVIC of the vastus medialis oblique and vastus lateralis did not significantly differ by tibial rotation during the stair ascent, the MVIC of the vastus medialis oblique was higher than that of the vastus lateralis during the internal and neutral rotations (p<.05). In addition, during the stair ascent, the displacement of the patella was more significant during the tibial external rotation than during the tibial internal and neutral rotations(p<.001). Thus, patients with patellofemoral pain are required to be considered the effects of tibial rotation for their rehabilitation.