• Title/Summary/Keyword: Direct method

Search Result 8,047, Processing Time 0.039 seconds

Calculation Method for Nominal Area of Rock Core Specimen During Direct Shear Test (암석코어시편의 절리면 직접전단시험을 위한 겉보기 면적 계산방법)

  • Kang, Hoon;Park, Jung-Wook;Park, Chan;Oh, Tae-Min;Cho, Jung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.6
    • /
    • pp.551-558
    • /
    • 2020
  • This note presents the calculation of nominal area for rock core specimen under direct shear testing condition. The initial nominal area was assumed as ellipsoid, and the equations for calculating the nominal area are derived. The normalized shear displacement and normalized nominal area have an identical relationship regardless of the ellipsoid shape. New testing constants and the generalized method were suggested to calculate the decrease of the nominal area. The method was applied to calculate the direct shear testing data and the changes of result were discussed.

Stable Intelligent Control of Chaotic Systems via Wavelet Neural Network

  • Choi, Jong-Tae;Choi, Yoon-Ho;Park, Jin-Bae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.316-321
    • /
    • 2003
  • This paper presents a design method of the wavelet neural network based controller using direct adaptive control method to deal with a stable intelligent control of chaotic systems. The various uncertainties, such as mechanical parametric variation, external disturbance, and unstructured uncertainty influence the control performance. However, the conventional control methods such as optimal control, adaptive control and robust control may not be feasible when an explicit, faithful mathematical model cannot be constructed. Therefore, an intelligent control system that is an on-line trained WNN controller based on direct adaptive control method with adaptive learning rates is proposed to control chaotic nonlinear systems whose mathematical models are not available. The adaptive learning rates are derived in the sense of discrete-type Lyapunov stability theorem, so that the convergence of the tracking error can be guaranteed in the closed-loop system. In the whole design process, the strict constrained conditions and prior knowledge of the controlled plant are not necessary due to the powerful learning ability of the proposed intelligent control system. The gradient-descent method is used for training a wavelet neural network controller of chaotic systems. Finally, the effectiveness and feasibility of the proposed control method is demonstrated with application to the chaotic systems.

  • PDF

NUCLEAR FUEL CYCLE COST ESTIMATION AND SENSITIVITY ANALYSIS OF UNIT COSTS ON THE BASIS OF AN EQUILIBRIUM MODEL

  • KIM, S.K.;KO, W.I.;YOUN, S.R.;GAO, R.X.
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.306-314
    • /
    • 2015
  • This paper examines the difference in the value of the nuclear fuel cycle cost calculated by the deterministic and probabilistic methods on the basis of an equilibrium model. Calculating using the deterministic method, the direct disposal cost and Pyro-SFR (sodium-cooled fast reactor) nuclear fuel cycle cost, including the reactor cost, were found to be 66.41 mills/kWh and 77.82 mills/kWh, respectively (1 mill = one thousand of a dollar, i.e., $10^{-3}$ $). This is because the cost of SFR is considerably expensive. Calculating again using the probabilistic method, however, the direct disposal cost and Pyro-SFR nuclear fuel cycle cost, excluding the reactor cost, were found be 7.47 mills/kWh and 6.40 mills/kWh, respectively, on the basis of the most likely value. This is because the nuclear fuel cycle cost is significantly affected by the standard deviation and the mean of the unit cost that includes uncertainty. Thus, it is judged that not only the deterministic method, but also the probabilistic method, would also be necessary to evaluate the nuclear fuel cycle cost. By analyzing the sensitivity of the unit cost in each phase of the nuclear fuel cycle, it was found that the uranium unit price is the most influential factor in determining nuclear fuel cycle costs.

On the Efficient Data Transfer Method of Multimedia Data Processor (멀티미디어 데이타 처리기의 효율적인 데이타 전달 방법)

  • Chung, Ha-Jae
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.8
    • /
    • pp.1921-1929
    • /
    • 1997
  • This paper describes a direct transmission method of multimedia data stream between a multimedia data processor and a communication interface without using system memory. I propose the direct transfer method of multimedia data through the single data path, without additional data path between a multimedia data processor and a communication interface in multimedia platforms. The hardware architecture and functions for the direct transfer method is defined. Procedure to transfer multimedia data to and from the multimedia data processor is described by means of control flow chart. Comparing the proposed method with general methods, I show that the proposed method can decrease number of bus accesses and bus cycles.

  • PDF

Improvement of prediction methods of power increase in regular head waves using calm-water and resistance tests in waves

  • Chun, Ho-Hwan;Lee, Cheol-Min;Lee, Inwon;Choi, Jung-Eun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.278-291
    • /
    • 2021
  • This paper applies load variation method to predict speed-power-rpm relationship along with propulsive performances in regular head waves, and to derive overload factors (ITTC, 2018). 'Calm-water tests' and 'resistance test in waves' are used. The modified overload factors are proposed taking non-linearity into consideration, and applied to the direct powering, and resistance and thrust identity method. These indirect methods are evaluated through comparing the speed-power-rpm relationships with those obtained from the resistance and self-propulsion tests in calm water and in waves. The objective ship is KVLCC2. The load variation method predicts well the speed-power-rpm relationship and propulsion performances in waves. The direct powering method with modified overload factors also predicts well. The resistance and thrust identity method with modified overload factor predicts with a little difference. The direct powering method with overload factors predicts with a relatively larger difference.

An Efficient Direct Signal-Based Direction of Arrival Estimation Using Uniform Rectangular Array

  • Cho, Seokhyang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.10
    • /
    • pp.89-94
    • /
    • 2022
  • This paper proposes a computationally efficient 2-D direction-of-arrival (DoA) estimation method with a uniform rectangular array (URA). This method is called the direct signal-based method in the sense that it is based directly on the phase relationships among the signals arriving at each antenna of an antenna array rather than their correlation matrix. According to the simulation results, it has be shown that the direct signal-based method, with much less computations than any existing methods, yields the performance comparable to that of the MUSIC (MUltiple SIgnal Classification) method in terms of the root-mean-squared error (RMSE) and the maximum absolute error.

Evaluation of Pyrosequencing Method for a BRAFV600E Mutation Test

  • Oh, Seo Young;Lee, Hoon Taek
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.17-23
    • /
    • 2015
  • A fine needle aspiration biopsy (FNAB) is the primary means of distinguishing benign from malignant in thyroid nodules. However, between 10 and 30% of the FNABs of thyroid nodules are diagnosed as 'indeterminate'. A molecular method is needed to reduce unnecessary surgery in this group. In Korea, most thyroid cancer is classic papillary type and BRAFV600E mutation is highly prevalent. Thus, this study compared the pyrosequencing method with the conventional direct DNA sequencing and PCR-RFLP analysis and investigated the evaluation of preoperative BRAFV600E mutation analysis as an adjunct diagnostic method with routine FNABs. Sixty-five (78.3%) of 83 histopathologically diagnosed malignant nodule revealed positive BRAFV600E mutation on pyrosequencing analysis. In detail, 65 (83.8%) of 78 papillary thyroid carcinomas sample showed positive BRAFV600E mutation. None of 29 benign nodules had in pyrodequencing, direct DNA sequencing and PCR-RFLP. Out of 31 thyroid nodules classified as 'indeterminate' on cytological examination preoperatively, 28 cases turned out to be malignant: 24 papillary thyroid carcinomas. Among that, 16 (66.7%) classic papillary thyroid carcinomas had BRAFV600E mutation. Among 65 papillary thyroid carcinomas with positive BRAFV600E mutation detected by pyrosequencing analysis, each 3 cases and 5 cases did not show BRAFV600E mutation by direct DNA sequencing and PCR-RFLP analysis. Therefore, pyrosequencing was superior to direct DNA sequencing and PCR-RFLP in detecting the BRAFV600E mutation of thyroid nodules (p =0.027). Detecting BRAFV600E mutation by pyrosequencing was more sensitivity, faster than direct DNA sequencing or PCR-RFLP.

Sea trial results of long range underwater acoustic communication based on direct sequence spread spectrum transmission in the East Sea (동해에서 직접수열 대역확산 전송에 기반한 장거리 수중음향통신의 해상실험 결과)

  • Ra, Hyung-in;An, Jeong-ha;Youn, Chang-hyun;Kim, Ki-man;Kim, In-soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.304-313
    • /
    • 2021
  • This paper presents the results of a sea trial for long range underwater acoustic communication conducted in the East Sea in November 2020. Signals were collected through a moving transmitter and 16 vertically arranged receivers, and the range between the transmitter and receiver was about 20 km. The signal in the experiment is a conventional Direct Sequence Spread Spectrum (DSSS) method and a superimposed DSSS method that increases data rate by superimposing of multiple circulated Pseudo Noise (PN) sequences for each symbol. The results show that the uncoded bit error rate averaged over 16 channels to which the channel coding technique was not applied was 0.0005 for the conventional direct sequence spreading method, and was 0.00124 for the superimposed direct sequence spreading method.

Performance Analysis of Water/Air Direct Contact Air Conditioning System (물-공기 직접접촉식 공기조화장치의 성능해석)

  • 유성연;권화길;김광영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.