• Title/Summary/Keyword: Direct evaluation method

Search Result 604, Processing Time 0.025 seconds

Modified indirect evaluation method for deterioration assessment of drinking water pipes (상수도 노후도 평가를 위한 수정 간접평가법)

  • Kwon, Hyuk Jaea
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.697-703
    • /
    • 2023
  • In this study, a modified indirect evaluation method was developed to predict the deterioration level of water pipes. The accuracy of the modified method was verified by comparing it with the direct method. The weights of index were adjusted by reducing the weight of water quality corrosion, soil corrosion, lay depth and road type according to the importance of the existing evaluation factors and adding the weight of pipe thickness. In the results, the weight of pipe thickness was determined to be 0.1530. Comparing with the direct evaluation method, the accuracy of the modified indirect evaluation method increased by 31.03% compared to the indirect evaluation method. The modified indirect evaluation method will be able to select relatively old pipes more accurately and efficiently than the existing indirect evaluation method when prioritizing the improvement of old water pipes.

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Evaluation of New Direct Dyes for Mutagenicity Using the Salmonella Mammalian Mutagenicity Assay

  • Bae Jin-Seok;Freeman Harold S.
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.297-305
    • /
    • 2005
  • A series of new direct dyes based on benzidine congeners, 2,2'-dimethyl-5,5'-dipropoxybenzidine and 5,5'-dipropoxybenzidine, were evaluated for mutagenicity in Salmonella typhimurium strains TA98 and TA100. All of the dyes examined were judged to be non-mutagenic with and without metabolic activation while toxicity was seen in some dyes at high doses. The study also suggested that the standard Salmonella mutagenicity plate-incorporated assay was an excellent method for evaluation of direct dyes for mutagenicity.

A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis (임플란트와 상부보철물의 임상적/실험적 부적합 평가에 관한 문헌고찰)

  • Kim, Jong-Hoi;Cho, Woong-Rae;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.56 no.9
    • /
    • pp.462-478
    • /
    • 2018
  • The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.

  • PDF

Evaluation of the Crack Initiation of Curved Compact Tension Specimens of a Zr-2.5Nb Pressure Tube Using the Unloading Compliance and Direct Current Potential Drop Methods (제하 컴플라이언스법 및 직류전위차법을 이용한 Zr-2.5Nb 압력관 휘어진 CT 시편의 균열시작 평가)

  • Jeong, Hyeon-Cheol;Ahn, Sang-Bok;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.8 s.239
    • /
    • pp.1118-1122
    • /
    • 2005
  • The direct current potential drop (DCPD) method and the unloading compliance (UC) method with a crack opening displacement gauge were applied simultaneously to the Zr-2.5Nb curved compact tension (CCT) specimens to determine which of the two methods can precisely determine the crack initiation point and hence the crack length for evaluation of their fracture toughness. The DCPD method detected the crack initiation at a smaller load-line displacement compared to the UC method. As a verification, a direct observation of the fracture surfaces on the curved compact tension specimens was made on the CCT specimens experiencing either 0.8 to 1.0 mm load line displacement or various loads from $50\%\;to\;80\%$ of the maximum peak load, or $P_{max}$. The DCPD method is concluded to be more precise in determining the crack initiation and fracture toughness, J in Zr-2.5Nb CCT specimens than the UC method.

Effects of particle size and adaptation duration on the digestible and metabolizable energy contents and digestibility of various chemical constituents in wheat for finishing pigs determined by the direct or indirect method

  • Fan, Yuanfang;Guo, Panpan;Yang, Yuyuan;Xia, Tian;Liu, Ling;Ma, Yongxi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.4
    • /
    • pp.554-561
    • /
    • 2017
  • Objective: This experiment was conducted as a $3{\times}2{\times}2$ factorial design to examine the effects of particle size (mean particle size of 331, 640, or $862{\mu}m$), evaluation method (direct vs indirect method) and adaptation duration (7 or 26 days) on the energy content and the apparent total tract digestibility (ATTD) of various chemical components in wheat when fed to finishing pigs. Methods: Forty-two barrows ($Duroc{\times}Landrace{\times}Yorkshire$) with an initial body weight of $63.0{\pm}0.8kg$ were individually placed in metabolic cages and randomly allotted to 1 of 7 diets with 6 pigs fed each diet. For the indirect method, the pigs were fed either a corn-soybean meal based basal diet or diets in which 38.94% of the basal diet was substituted by wheat of the different particle sizes. In the direct method, the diets contained 97.34% wheat with the different particle sizes. For both the direct and indirect methods, the pigs were adapted to their diets for either 7 or 26 days. Results: A reduction in particle size linearly increased the digestible energy (DE) and metabolizable energy (ME) contents as well as the ATTD of gross energy, crude protein, organic matter, ether extract (EE) and acid detergent fiber (ADF) (p<0.05), and had a trend to increase the ATTD of dry matter of wheat (p = 0.084). The DE, ME contents, and ATTD of gross energy, crude protein, dry matter and organic matter were higher (p<0.05) when determined by the direct method, but the ATTD of ADF, EE, and neutral detergent fiber were higher when determined by the indirect method (p<0.05). Prolongation of the adaption duration decreased the ATTD of neutral detergent fiber (p<0.05) and had a trend to increase the ATTD of EE (p = 0.061). There were no interactions between particle size and the duration of the adaptation duration. The ATTD of EE in wheat was influenced by a trend of interaction between method and adaptation duration (p = 0.074). The ATTD of ADF and EE in wheat was influenced by an interaction between evaluation method and wheat particle size such that there were linear equations (p<0.01) about ATTD of ADF and EE when determined by the direct method but quadratic equations (p = 0.073 and p = 0.088, respectively) about ATTD of ADF and EE when determined by the indirect method. Conclusion: Decreasing particle size can improve the DE and ME contents of wheat; both of the direct and indirect methods of evaluation are suitable for evaluating the DE and ME contents of wheat with different particle sizes; and an adaptation duration of 7 d is sufficient to evaluate DE and ME contents of wheat in finishing pigs.

APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION (열화 진단 평가를 위한 직류 누설법의 활용)

  • Lee, Kwan-Woo;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

Evaluation of New Metallized Direct Dyes for Mutagenicity Using the Salmonella Mammalian Mutagenicity Assay

  • Rae Jin-Seok;Freeman Harold S.
    • Fibers and Polymers
    • /
    • v.6 no.3
    • /
    • pp.235-243
    • /
    • 2005
  • A series of new metallized direct dyes based on benzidine congeners, 2,2'-dimethyl-5,5'-dipropoxybenzidine and 5,5'-dipropoxybenzidine, were evaluated for mutagenicity in Salmonella typhimurium strains TA98 and TA 100. All of the dyes examined were judged to be non-mutagenic with and without metabolic activation while toxicity was seen in some dyes at high doses. The study also suggested that the standard Salmonella mutagenicity plate-incorporated assay was an excellent method for evaluation of dyes for mutagenicity.

Criteria for clinical translucency evaluation of direct esthetic restorative materials

  • Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.159-166
    • /
    • 2016
  • The purpose of this review was to suggest practical criteria for the clinical translucency evaluation of direct esthetic restorative materials, and to review the translucency with these criteria. For the evaluation of reported translucency values, measuring instrument and method, specimen thickness, background color, and illumination should be scrutinized. Translucency parameter (TP) of 15 to 19 could be regarded as the translucency of 1 mm thick human enamel. Visual perceptibility threshold for translucency difference in contrast ratio (${\Delta}CR$) of 0.07 could be transformed into ${\Delta}TP$ value of 2. Translucency differences between direct and indirect resin composites were perceivable (${\Delta}TP>2$). Universal and corresponding flowable resin composites did not show perceivable translucency differences in most products. Translucency differed significantly by the product within each shade group, and by the shade group within each product. Translucency of human enamel and perceptibility threshold for translucency difference may be used as criteria for the clinical evaluation of translucency of esthetic restorative materials.

Assessment of Interruption Costs for Public Customers

  • Choi Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.186-192
    • /
    • 2005
  • As the power industry moves towards open competition, there has been a call for methodology to evaluate power system reliability by using customer interruption costs. This paper presents an evaluation of the interruption costs for public customers in Korea using customer survey methodology. When various research results are examined, the evaluation of direct interruption costs becomes much more simplified. Especially, in the case of public customers, it is known that the evaluation of direct interruption costs is more useful. Accordingly, this paper selected the customer survey method to evaluate the interruption costs for public customers in Korea considering interruption and customer characteristics.