• Title/Summary/Keyword: Direct estimation method

Search Result 450, Processing Time 0.033 seconds

Estimation of Forest Volumes in the Ecosystem Region Using Spatial Statistical Techniques (공간통계기법을 이용한 생태계 관리지역의 산림축적 추정)

  • SEO, Hwan-Seok;PARK, Jeong-Mook;KIM, Eun-Sook;LEE, Jung-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.149-160
    • /
    • 2015
  • This study aims to estimate the forest volumes of the upper region of Nam-Han River in ecosystem zoning by forest types and age classes, and to suggest the optimal estimation method through the comparison of the standard errors according to the spatial unit. In the estimation of forest volumes, we used both of direct estimation, which uses sample plots of the target area only, and synthetic estimation, which includes sample plots of the expanded areas as well as those of the target area. As for the spatial expansion, we applied four standards for synthetic estimator: Mountainous zone, Neighbor ecosystem region, Gangwon province, and Buffer zone. The results show that average forest volume per ha, calculated by direct estimation, was $143.5m^3/ha$, while that by synthetic estimation with each standard, was estimated at $146.9m^3/ha$ by Gangwon province, $144.8m^3/ha$ by Buffer zone, $139.8m^3/ha$ by Neighbor ecosystem region, and $138.6m^3/ha$ by Mountainous zone, respectively. The standard errors of direct estimation was $1.79m^3/ha$, while those of synthetic estimation showed not a great difference among the errors. Meanwhile, considering the standard errors by forest type, the lowest was ${\pm}2.3m^3/ha$ of broad-leaved forest, followed by ${\pm}3.3m^3/ha$ of mixed forest, and ${\pm}4.8m^3/ha$ of coniferous forest.

Small Area Estimation of Unemplyoment Using Kalman Filter Method (KALMAN FILTER기법을 이용한 실업자 수의 소지역 추정)

  • 양영춘;이상은;신민웅
    • The Korean Journal of Applied Statistics
    • /
    • v.16 no.2
    • /
    • pp.239-246
    • /
    • 2003
  • In small area estimation, Best Linear Unbaised Predictor(BLUP) can be directly implicated ,specially, in use of the time series estimation. If there are correlations between observations and error terms over the time, Kalman Filter method can be used. Therefore, using kalman Filtering technique small area estimation of total of unemployments are estimated by BLUP. And for the example of this study, Economic Active Population Survey data were used.

A Derivation of Aerosol Optical Depth Estimates from Direct Normal Irradiance Measurements

  • Yun Gon Lee;Chang Ki Kim
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.79-87
    • /
    • 2024
  • This study introduces a method for estimating Aerosol Optical Depth (AOD) using Broadband Aerosol Optical Depth (BAOD) derived from direct normal irradiance and meteorological factors observed between 2016 and 2017. Through correlation analyses between BAOD and atmospheric components such as Rayleigh scattering, water vapor, and tropospheric nitrogen dioxide, significant relationships were identified, enabling accurate AOD estimation. The methodology demonstrated high correlation coefficients and low Root Mean Square Errors (RMSE) compared to actual AOD500 measurements, indicating that the attenuation effects of water vapor and the direct impact of tropospheric nitrogen dioxide concentration are crucial for precise aerosol optical depth estimation. The application of BAOD for estimating AOD500 across various time scales-hourly, daily, and monthly-showed the approach's robustness in understanding aerosol distributions and their optical properties, with a high coefficient of determination (0.96) for monthly average AOD500 estimates. This study simplifies the aerosol monitoring process and enhances the accuracy and reliability of AOD estimations, offering valuable insights into aerosol research and its implications for climate modeling and air quality assessment. The findings underscore the viability of using BAOD as a surrogate for direct AOD500 measurements, presenting a promising avenue for more accessible and accurate aerosol monitoring practices, crucial for improving our understanding of aerosol dynamics and their environmental impacts.

Feasibility study of using triple-energy CT images for improving stopping power estimation

  • Yejin Kim;Jin Sung Kim ;Seungryong Cho
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1342-1349
    • /
    • 2023
  • The planning accuracy of charged particle therapy (CPT) is subject to the accuracy of stopping power (SP) estimation. In this study, we propose a method of deriving a pseudo-triple-energy CT (pTECT) that can be achievable in the existing dual-energy CT (DECT) systems for better SP estimation. In order to remove the direct effect of errors in CT values, relative CT values according to three scanning voltage settings were used. CT values of each tissue substitute phantom were measured to show the non-linearity of the values thereby suggesting the absolute difference and ratio of CT values as parameters for SP estimation. Electron density, effective atomic number (EAN), mean excitation energy and SP were calculated based on these parameters. Two of conventional methods were implemented and compared to the proposed pTECT method in terms of residuals, absolute error and root-mean-square-error (RMSE). The proposed method outperformed the comparison methods in every evaluation metrics. Especially, the estimation error for EAN and mean excitation using pTECT were converging to zero. In this proof-of-concept study, we showed the feasibility of using three CT values for accurate SP estimation. Our suggested pTECT method indicates potential clinical utility of spectral CT imaging for CPT planning.

System identification using the feedback loop (궤환 제어를 이용한 시스템 규명)

  • 정훈상;박영진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.409-412
    • /
    • 2001
  • Identification of systems operating in closed loop has long been of prime interest in industrial applications. The fundamental problem with closed-loop data is the correlation between the unmeasurable noise and the input. This is the reason why several methods that work in open loop fail when applied to closed-loop data. The prediction error based approaches to the closed-loop system are divided to direct method and indirect method. Both of direct and indirect methods are known to be applied to the closed-loop data without critical modification. But the direct method induces the bias error in the experimental frequency response function and this bias error may deteriorates the parameter estimation performance

  • PDF

A Study on Wall Emissivity Estimation using RPSO Algorithm (RPSO 알고리즘을 이용한 벽면 방사율 추정에 관한 연구)

  • Lee, Kyun-Ho;Baek, Seung-Wook;Kim, Ki-Wan;Kim, Man-Young
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2476-2481
    • /
    • 2007
  • An inverse radiation analysis is presented for the estimation of the wall emissivities for an absorbing, emitting, and scattering media with diffusely emitting and reflecting opaque boundaries. In this study, a repulsive particle swarm optimization(RPSO) algorithm which is a relatively recent heuristic search method is proposed as an effective method for improving the search efficiency for unknown parameters. To verify the performance of the proposed RPSO algorithm, it is compared with a basic particle swarm optimization(PSO) algorithm and a hybrid genetic algorithm(HGA) for the inverse radiation problem with estimating the wall emissivities in a two-dimensional irregular medium when the measured temperatures are given at only four data positions. A finite-volume method is applied to solve the radiative transfer equation of a direct problem to obtain measured temperatures.

  • PDF

The Estimation of the Energy Consumption and $C0_2$ Emission at the Construction Stage in the Apartment Housing (공동주택 건설단계 공종별 에너지소비량 및 이산화탄소 배출량 산정연구)

  • Kim, Dae-Hee;Kwon, Bo-Min;Choi, Young-Oh;Lee, Kang-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.328-333
    • /
    • 2006
  • A few methodologies have been recently developed to estimate the environmental affect when various materials and components are used in building life cycle. The direct survey method has limitations to analyze the environmental problems because of the limit of survey scope and cost. Therefore, another indirect method has been developed as alternatives. The indirect method is represented as input-output analysis. This paper aimed at analyzing the estimation the environmental affect of building materials and works at building construction, utilizing the input-output analysis as a indirect estimation method. The results suggested that the building works is overally responsible for the energy consumption and $CO_2$ emission. In other words, Over the 80% of the total consumption and $CO_2$ emission are resulted at the building work.

  • PDF

Efficiency Comparison according to Power Conversion Method and Performance Estimation for Battery Source BLDC Motor Propulsion System of Small Ships (축전지 전원을 사용한 소형선박 추진용 BLDC모터의 전력변환방식에 따른 효율 비교 및 성능 추정)

  • Jeong, T.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • We investigate some operation characteristics and energy efficiency of the BLDC motor system driven by different two types power conversion method depends on same battery source for applying to electrical motor propulsion system of a small ship. Also, we suggest an estimation manner of operating performances such as total running distance and operating speed of ships from basic discharge voltage characteristics of batteries. Through some experiments, direct power conversion was better than indirect method on the view point of energy efficiency and the voltage discharge characteristics could be used as important design factor for estimating operating performances of small ships driven by electrical motors.

Simplified Rotor and Stator Resistance Estimation Method Based on Direct Rotor Flux Identification

  • Wang, Mingyu;Wang, Dafang;Dong, Guanglin;Wei, Hui;Liang, Xiu;Xu, Zexu
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.751-760
    • /
    • 2019
  • Since parameter mismatch seriously impacts the efficiency and stability of induction motor drives, it is important to accurately estimate the rotor and stator resistance. This paper introduces a method to directly calculate the rotor flux that is independent of stator and rotor resistance and electrical angle. It is based on obtaining the rotor and stator resistance using the model reference adaptive system (MRAS) method. The method has a lower computation burden and less adaptation time when compared with other rotor resistance estimation methods. This paper builds three coordinate frames to analyze the rotor flux error and rotor resistance error. A number of implementation issues are also considered.

Non-coherent TOA Estimation Method based on IR-UWB in Multiple SOP Environments (다중 SOP 환경하에서 IR-UWB 기반의 Non-coherent TOA 추정 기법)

  • Park, Woon-Yong;Park, Cheol-Ung;Choi, Sung-Soo;Lee, Won-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11A
    • /
    • pp.1086-1095
    • /
    • 2007
  • This paper proposes a novel non-coherent TOA estimation scheme using multiple correlation process on the existence of multiple simultaneously operating piconets (SOPs). Impulse radio-ultra wideband (IR-UWB) based on direct sequence spread spectrum (DSSS) using Gold sequence is employed in order to discriminate each piconet. In order to enhance the characteristic of correlation, this paper presents the method of multiple mask operation (MMO). The time of arrival (TOA) of direct line of sight (DLOS) path is estimated via two step coarse/fine timing detection. To verify the performance of proposed scheme, two distinct channel models approved by IEEE 802.15.4a Task Group (TG) are considered. According to the simulation results, it could conclude that the proposed scheme have performed better performance than the conventional method well even in densed indoor multi-path environment as well as in the existence of multiple SOPs.