• Title/Summary/Keyword: Direct Measurement

Search Result 1,585, Processing Time 0.026 seconds

AN INSTURMNETED SEINGLE TREE FOR DIRECT DRAFT MEASUREMENT OF ANIMAL DRAWIN IMPLEMENTS

  • Paskikatan, M.C.;Quick, G.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.307-315
    • /
    • 1993
  • A direct draft measurement system was developed based on the swingle tree- the rear component of the single-animal harnessing (or yoking) system . The prototype was made from a tube, on which four strain gages were attached. The pull of the draft animal through the flexible pull chains or ropes causes the beam to bend, The bending strain is sensed by the strain gages and the bridge converts this to a voltage signal. Counterweights keep the tube correctly oriented if the angle of pull changes , while end bearing follow the variations in the angle of pull. Hence, the voltage output is proportional to the draft. the device has highly linear response, acceptable sensitivity negligible error and hysteresis. It is suitable for electronic data acquisition, non-intrusive , easy to attach and detach and is reasonably priced.

  • PDF

Flow force compensation by stepped spool (계단형상에 의한 스풀밸브의 유동력 보상)

  • 신원규;최현영;신효필;문의준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.745-749
    • /
    • 2002
  • This paper is on the study of flow force compensating method of spool type valve. A simple flow force compensating method using stepped spool is presented in this paper. It is easy to manufacture stepped spool in the presented method because the shape of it is simple. The method has the merit that the size of valve need not be increased. Actuating force required for driving means of spool can be decreased by the compensation of flow force. The effect of presented method is predicted through CFD analysis. The prototypes of flow force compensating Direct Drive Servo-Valve where the result of CFD analysis is reflected are manufactured, and the measurement of flow force is carried out. It is known from the measurement that the effect of flow force compensation is very similar to from CFD analysis.

  • PDF

Direct Analysis of Aerosol Particles by Atomic Emission and Mass Spectrometry

  • Kawaguchi, Hiroshi;Nomizu, Tsutomu;Tanaka, Tomokazu;Kaneco, Satoshi
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.411-418
    • /
    • 1995
  • A method for the direct determination of elemental content in each of aerosol particles by inductively coupled plasma atomic emission (ICP-AES) or mass spectrometry (ICP-MS) is described. This method is based upon the introduction of diluted aerosol into an ICP and the measurement of either the flash emission intensities of an atomic spectral line or ion intensities. A pulse-height analyzer is used for the measurement of the distribution of the elemental content. In order to calibrate the measuring system, monodisperse aerosols are used. The potentials of the method are shown by demonstrating the copper emission signals from the aerosols generated at a small electric switch, a study of the relation between the decreasing rate of particle number density and particle size, and measurements of calcium contents in the individual biological cells.

  • PDF

SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect (SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정)

  • 정준영
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

Implantation of DC Optical Current Sensor Based on Faraday Effect for HVDC (페러데이 효과를 이용한 특고압 직류전송용 광전류 센서 구현)

  • Kim, Kwang Taek;Chung, Dae Won;Kim, Young Soo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.187-190
    • /
    • 2019
  • We proposed and demonstrated DC(direct current) optical current sensor based on Faraday effect for HVDC(high voltage direct current). The RIG((Bi1.3Gd0.43Y1.27)Fe5O12) was adopted as Faraday device because of its high Verdet constant and good thermal stability. The differential amplification scheme for signal processing was present. The sensor showed high linear response for the input current. Measurement range of the sensor was 0~200A and measurement error was less than 1%.

A Study on somatotypes of 18-54 yars old females (18-54세 여성의 연령집단별 체형 차이 연구)

  • 권숙희
    • Journal of the Korean Home Economics Association
    • /
    • v.36 no.5
    • /
    • pp.17-27
    • /
    • 1998
  • The need for periodic investigation on human growth rate and somatotypes has been increased because the scientific development and environmental factors have effected a lot on them recently. This study aimed to investigate the changes of the 638 female somatotypes in the age of 18-54 obtained by direct and indirect measurement. The measurement data were divided into 4 groups early young women age group (18-54), late young women age group (25-34), early middle age group (35-44), late middle age group (45-54) and compared each other based on each group by age. The results obtained from this study were as follows: 1. According to Mollison Curve based on the early young women, items of depth decreased overall and pp.P. length & shoulder length increased as the age increased. The circumference, breadth and thickness tended to increase, especially waist girth and thickness of waist increased markedly. The data showed that the increase rate of thickness was higher than that of breadth. 2. Gradual somatotype changes were observed by overlapping projection drawings obtained by direct measurement. Compared with the young women, the middle aged showed lower should point depth and hip line & crotch depth line were lengthened significantly. No significant difference was observed in overlapping of the early young women and the late young women' figure, neither was in early middle aged and the late middle aged. 3. By overlapping the side view of the young women group (18-37) and middle aged group (35-54), no significant postural characteristics were found, while the back tended to bend forward and the abdomen and hip appeared to get fat.

  • PDF

Spectral Estimation of the Pass-by Noise of an Acoustic Source (등속 이동 음원의 통과소음 스펙트럼 추정에 관한 연구)

  • Lim Byoung-Duk;Kim Deok-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1597-1604
    • /
    • 2005
  • The identification of a moving noise source is important in reducing the source power of the transport systems such as airplanes or high speed trains. However, the direct measurement using a microphone running with noise source is usually difficult due to wind noise, white the source motion distorts the frequency characteristics of the pass-by sound measured at a fixed point. In this study the relationship between the spectra of the source and the pass-by sound signal is analyzed for an acoustic source moving at a constant velocity. Spectrum of the sound signal measured at a fixed point has an integral relationship with the source spectrum. Nevertheless direct conversion of the measured spectrum to the source spectrum is ill-posed due to the singularity of the integral kernel. Alternatively a differential equation approach is proposed, where the source characteristics can be recovered by solving a differential equation relating the source signal to the distorted measurement in time domain. The parameters such as the source speed and the time origin, required beforehand, are also determined only from the frequency-phase relationship using an auxiliary measurement. With the help of the regularization method, the source signal is successfully recovered. The effects of the parameter errors to the estimated frequency characteristics of the source are investigated through numerical simulations.

Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측)

  • Ahn, Byoung-Ha;Shim, Jae-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.

A Theoretical Analysis on Somatotyping of Elderly Women (노년기 여성의 체형 연구에 대한 이론적 분석)

  • Lee, Eun-Jung
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.4 no.1 s.7
    • /
    • pp.35-41
    • /
    • 2006
  • From 1995 to 2005 the information related to clothing and textiles publicized by 6 journals regarding Elder Women's body type was collected and analyzed. The results are as follows. 1. It has been investigated into the elder woman's body type since 1995, and this subject needs a detailed study. in audition, investigation into woman's body type has been studied parts of the body for clothing construction. 2. Analysis result for measure area preponderance(Seoul area and local metropolitan city) of area, measure subject number mainly to large scale group more than 300 people that measure is consisting most know can. 3. Where the way of measurement is concerned, there are direct measurements more than indirect measurements. In case of using just direct measurement, the study often mentions necessity of indirect measurements. Therefore it is thought simultaneous measurement is the most desirable. 4. A Body type characteristic of elder woman shows a size of every part diminishes as growing older. Owing mainly to obesity of waist and abdomen, they have a changed body a measure of around the abdomen is bigger than around the hips. hips drop and the upper half of the body down, and besides, feet are changed into the flat.

  • PDF

Cluster Analysis for Foot Type (II) -The subject of the college men between the age of 19~24 years- (발의 형태 분석을 위한 군집분석(II) -19~24세 남자대학생을 중심으로-)

  • 문명옥
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.5
    • /
    • pp.637-645
    • /
    • 1994
  • The purpose of this study was to analyze the characteristics of men's foot and the foot type by cluster analysis for men's footwear. The sample size for the study was 200 college men between age 19 and 24 in Pusan urban area. There were measured 17 items of the foot for factor analysis and cluster analysis. The result was as follows: 1. The size of If items of men's foot is larger than women's foot. 2. There were 9 items selected by factor analysis. 3. The cluster analysis of the direct measurement: Cluster 1: The items of the direct measurement is all much the same to mean value of this age group. Cluster 2: The foot size is relatively small to other clusters. Cluster 3: The foot size is relatively large to other clusters. 4. The cluster analysis of indirect measurement: Cluster 1: The foot print angle is the most value and Metatarso-Phalanx angle is nomral Cluster 2: The foot print angle is middle and Metatarso-Phalanx angle is normal. Cluster 3: The foot print angle is high and Metatarso-Phalanx angle is the smallest. Cluster 4: The foot print angle is low and Metatarso-Phalanx angle is all the much same to mean value of this age group.

  • PDF