• Title/Summary/Keyword: Direct Load Control

Search Result 290, Processing Time 0.034 seconds

A Position Sensorless Motion Control System of Reluctance Synchronous Motor with Direct Torque Control (직접토크제어에 의한 위치센서 없는 리럭턴스 동기전동기의 위치제어 시스템)

  • Kim, Min-Huei;Lee, Bok-Yong;Kim, Kyung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.135-141
    • /
    • 2002
  • This paper presents an implementation of high-dynamic performance of position sensorless motion control system of Reluctance Synchronous Motor(RSM) drives for an industrial servo system with direct torque control(DTC), The problems of DTC for high-dynamic performance and maximum efficiency RSM drive due to a saturated stator linkage flux and nonlinear inductance curve with various load currents, The accurate estimation of the stator flux and torque are obtained using stator flux observer of which a saturated inductance Ld and Lq can be compensated by adapting from measurable the modulus and angle of the stator current space vector. To obtain fast torque response and maximum torque/current with varying load current, the reference command flux is ensured by imposing Ids=Iqs. This control strategy is proposed to fast response and optimal efficiency for RSM drive. In order to prove rightness of the suggested control algorithm, the actual experiment carried out at ${\pm}$20 and ${\pm}$1500 rpm. The developed digitally high-performance control system are shown some good response characteristic of control results and high performance features using 1.0kW RSM of which has 2.57 Ld/Lq salient ratio.

  • PDF

Electronic Control of Braking Force Distribution for Vehicles Using a Direct Adaptive Fuzzy Controller

  • Kim, Hunmo;Kim, Seungdae;Sung, Yoon-Gyeoung
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.66-80
    • /
    • 2001
  • In brake systems, a proportioning valve(P. V), which reduces the brake line pressure on each wheel cylinder for the anti-locking of rear wheels, is closely related to the safety of vehicles. However, it is impossible for current P. V. s to completely control brake line pressure because, mechanically, it is an open loop control system. In this paper we describe an electronic brake force distribution system using a direct adaptive fuzzy controller in order to completely control brake line pressure using a closed loop control system. The objective of the electronic brake force distribution system is to change the cut-in-pressure and the valve slop of the P. V in order to obtain better performance of the brake system than with mechanical systems.

  • PDF

Robust Adaptive Precision Position Control of PMSM

  • Ko Jong-Sun;Ko Sung-Hwan;Kim Yung-Chan
    • Journal of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.347-355
    • /
    • 2006
  • A new control method for precision robust position control of a permanent magnet synchronous motor (PMSM) is presented. In direct drive motor systems, a load torque disturbance directly affects the motor shaft. The application of the load torque observer is published in using a fixed gain to solve this problem. However, the motor flux linkage cannot be determined precisely for a load torque observer. Therefore, an asymptotically stable adaptive observer base on a deadbeat observer is considered to overcome the problems of unknown parameters, torque disturbance and a small chattering effect. To find the critical parameters the system stability analysis is carried out using the Liapunov stability theorem.

PID Controller and Derivative-feedback Gain Design of the Direct-drive Servo Valve Using the Root Locus and Manual Tuning (근궤적과 수동 조정에 의한 직접 구동형 서보밸브의 PID 제어기 및 미분피드백 이득 설계)

  • Lee, Seong Rae
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.15-23
    • /
    • 2016
  • The direct-drive servo valve(DDV) is a kind of one-stage valve because the main spool valve is directly driven by the dc motor. Since the DDV structure is simple, it is less expensive, more reliable, and offers a reduced internal leakage and a reduced sensitivity to fluid contamination. The control system of the DDV is highly nonlinear due to a current limiter, a voltage limiter, and the flow-force effect on the spool motion. The shape of the step response of the DDV-control system varies considerably according to the magnitudes of the step input and the load pressure. The system-design requirements mean that the overshoots should be less than 20%, and the errors at 0.02s should be less than 2%, regardless of the reference-step input sizes of 1V and 5V and the load-pressure magnitudes of 0MPa and 20.7MPa. To satisfy the system-design requirements, the PID-controller parameters of $K_c$, $T_i$ and $T_d$, and the derivative-feedback gain of $K_{der}$ are designed using the root locus and manual tuning.

Sliding Mode Control Based DTC of Sensorless Parallel-Connected Two Five-Phase PMSM Drive System

  • Kamel, Tounsi;Abdelkader, Djahbar;Said, Barkat;Al-Hitmi, M.;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1185-1201
    • /
    • 2018
  • This paper presents a sensorless direct torque control (DTC) combined with sliding mode approach (SM) and space vector modulation (SVM) to achieve mainly a high performance and reduce torque and flux ripples of a parallel-connected two five-phase permanent magnet synchronous machine (PMSM) drive system. In order to increase the proposed drive robustness and decrease its complexity and cost, the rotor speeds, rotor positions, fluxes as well as torques are estimated by using a sliding mode observer (SMO) scheme. The effectiveness of the proposed sliding mode observer in conjunction with the sliding mode control based DTC is confirmed through the application of different load torques for wide speed range operation. Comparison between sliding mode control and proportional integral (PI) control based DTC of the proposed two-motor drive is provided. The obtained speeds, torques and fluxes responses follow their references; even in low and reverse speed operations, load torques changes, and machines parameters variations. Simulation results confirm also that, the ripples of the torques and fluxes are reduced more than 3.33% and 16.66 %, respectively, and the speed overshoots and speed drops are reduced about 99.85% and 92.24%, respectively.

A New Improved Continuous Variable Structure Tracking Controller For BLDD Servo Motors (브러쉬없는 직접구동 전동기를 위한 새로운 개선된 연속 가변구조 추적제어기)

  • Lee, Jung-Hoon
    • Journal of IKEEE
    • /
    • v.9 no.1 s.16
    • /
    • pp.47-56
    • /
    • 2005
  • A new improved robust variable structure tracking controller is presented to provide an accurately prescribed tracking performance for brushless direct drive(BLDD) servo motors(SM) under uncertainties and load variations. A special integral sliding surface suggested for removing the reaching phase problems can define its ideal sliding mode and virtual ideal sliding trajectory from an initial position of SM. The tracking error caused by the nonzero value of the sliding surface is derived. A corresponding continuous control input with the disturbance observer is suggested to track a predetermined virtual ideal sliding trajectory within a prescribed value under all the uncertainties and load variations. The usefulness of the proposed algorithm is demonstrated through the comparative simulations for a BLDD SM under load variations.

  • PDF

Determination of Incentive Level of Direct Load Control using Monte Carlo Simulation with Variance Reduction Technique (몬테카를로 시뮬레이션을 이용한 직접부하제어의 제어지원금 산정)

  • Jeong Yun Won;Park Jong Bae;Shin Joong Rin;Chae Myung Suk
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.666-670
    • /
    • 2004
  • This paper presents a new approach for determining an accurate incentive levels of Direct Load Control (DLC) program using sequential Monte Carlo Simulation (MCS) techniques. The economic analysis of DLC resources needs to identify the hourly-by-hourly expected energy-not-served resulting from the random outage characteristics of generators as well as to reflect the availability and duration of DLC resources, which results the computational explosion. Therefore, the conventional methods are based on the scenario approaches to reduce the computation time as well as to avoid the complexity of economic studies. In this paper, we have developed a new technique based on the sequential MCS to evaluate the required expected load control amount in each hour and to decide the incentive level satisfying the economic constraints. And also the proposed approach has been considered multi-state as well as two-state of the generating units. In addition, we have applied the variance reduction technique to enhance the efficiency of the simulation. To show the efficiency and effectiveness of the suggested method the numerical studies have been performed for the modified IEEE reliability test system.

  • PDF

Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method (단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성)

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • This paper investigates operating characteristics of three-phase matrix converter with unity input power factor by direct duty-ratio pulse-width modulation in the case of balanced and unbalanced load. It can be found from the system analysis that (1) The control algorithm for unity power factor is not related to the variables of load sides but the input voltages, (2) With the balanced three-phase load except for the pure reactive load, the unity input power factor can be achieved, (3) In the case of the unbalanced linear load, the equivalent input characteristics of the matrix converter can be seen like the nonlinear resister, (4) When the input frequency and the output frequency have the specific relationship, each input phases have the same sharing of the average power. The feasibility and validity of the analysis were verified by simulation and experimental results.

Analysis of Load Value acting Free Falling Object according to Disturbance using Nonlinear Load Control Model (비선형 하중 제어 모델에서 외란에 따른 자유낙하 물체에 작용하는 하중값 분석)

  • Wang, Hyeon-Min;Woo, Kwang-Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.2
    • /
    • pp.55-59
    • /
    • 2010
  • Recently it is tried to use load control model for maneuver moving object. MIN design method proposed to solve control problem of nonlinear system using load concept. The Min design method shows direct method for finding control value on the load control model. In this paper, is shown realization free falling model using nonlinear load control model and analysis of load values acting falling object according to disturbance. And made a trajectory according to acting load values due to disturbance. This paper's result is able to be applied to design algorithm for improvement accuracy of MLRS, GPS air-to-surface missile(ASM) and returning spacecraft with nonlinear model predictive control.

High Performance Current Controller for Sparse Matrix Converter Based on Model Predictive Control

  • Lee, Eunsil;Lee, Kyo-Beum;Lee, Young Il;Song, Joong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1138-1145
    • /
    • 2013
  • A novel predictive current control strategy for a sparse matrix converter is presented. The sparse matrix converter is functionally-equivalent to the direct matrix converter but has a reduced number of switches. The predictive current control uses a model of the system to predict the future value of the load current and generates the reference voltage vector that minimizes a given cost function so that space vector modulation is achieved. The results show that the proposed controller for sparse matrix converters controls the load current very effectively and performs very well through simulation and experimental results.