• Title/Summary/Keyword: Direct Load Control

Search Result 290, Processing Time 0.121 seconds

Research for Activation of Direct Load Control Program in Power Market (직접부하제어프로그램의 활성화 위한 해외사례별 연구)

  • Lee, C.J.;Kim, J.H.;Park, J.B.;Shin, J.R.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.578-580
    • /
    • 2003
  • This paper describes a research for activation of diect load control program in competitive electicity market. A direct load control program after the restructuring of electric power industry will evolve to the bilateral information system to derive a voluntary participation of demand side resource. Therefore, this paper presented a right way of direct load control program for the foreign market research.

  • PDF

Development of the Load Curtailment Allocation Algorithm for Load Aggregator in Emergency Demand Response (부하관리사업자의 비상시 부하제어량 배분 알고리즘 개발)

  • 정구형;김진호;김발호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.8
    • /
    • pp.466-471
    • /
    • 2004
  • Electricity industries throughout the world are undergoing unprecedented changes. As a result, these changes lead to the separation of traditional integrated utilities and the introduction of competition in order that increase efficiency in electricity industry. Direct load control (DLC) system in competitive electricity market has a hierarchical interactive operation system, therefore, its control logic is also applied by bilateral interactive method that interchanges information related to interruptible load between operation hierarchies. Consequently, load curtailment allocation algorithm appropriate for new DLC system is required, and based on interchanged information, this algorithm should be implemented by most efficient way for each operation hierarchy. In this paper, we develop the load curtailment allocation algorithm in an emergency for new DLC system. Especially, the optimal algorithm for load aggregator (LA) that participates in competitive electricity market as a main operator for load management is developed.

Comparative study of control strategies for the induction generators in wind energy conversion system

  • Giribabu, D.;Das, Maloy;Kumar, Amit
    • Wind and Structures
    • /
    • v.22 no.6
    • /
    • pp.635-662
    • /
    • 2016
  • This paper deals with the comparison of different control strategies for the Induction generators in wind energy conversion system. Mainly, two types of induction machines, Self excited induction generator (SEIG) and doubly Fed Induction generators (DFIG) are studied. The different control strategies for SEIG and DFIG are compared. For SEIG, Electronic load Controller mechanism, Static Compensator based voltage regulator are studied. For DFIG the main control strategy namely vector control, direct torque control and direct power control are implemented. Apart from these control strategies for both SEIG and DFIG to improve the performance, the ANFIS based controller is introduced in both STATCOM and DTC methods. These control methods are simulated using MATLAB/SIMULINK and performances are analyzed and compared.

A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system (교류-직류 연계계통에 있어서 직류제어방식의 비교연구)

  • 정형환;왕용필;안병철;이광우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF

POWER LOAD MANAGEMENT FOR PEAK LOAD CLIPPING (POWER LOAD DIRECT CONTROL METHOD) (Peak부하(負荷) 억제(抑制)를 위한 전력부하관리(電力負荷管理) (전력부하(電力負荷) 직접제어방식(直接制御方式)))

  • Kim, Yeong-Han;Lee, Hyo-Sang;Kim, Jai-Young
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.246-250
    • /
    • 1989
  • Owing to the rapid development of economy and the higher living standard of people, electricity demands have growth and the peak load has been increased rapidly. To cope with this impacts and to reduce the cost of service,utilities are conserned about power load management program. This paper shows a scheme of power load control and the basic structure of direct load control system. And also radio control method using the public pager which is one of the best economical and serviceable method in techniques will be introduced briefly.

  • PDF

An Allocation Strategy for Direct Load Control Program Resources in Power Systems (전력계통운전상황을 고려한 직접부하제어자원의 배분전략)

  • Cho, K.S.;Lee, C.J.;Park, J.B.;Shin, J.R.;Kim, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.444-446
    • /
    • 2003
  • This paper deals with an allocation strategy for the resources of direct load control program, which is considered the operating states in power systems. The existing approaches, load shedding priority algorithm, curtailment payback based algorithm and mixed curtailment algorithm, are based on the uniform allocation strategy. These approaches are not taken into account the operating states in power systems. So, under the critical operating condition, direct load control resource is evaluated by introducing the congestion factor.

  • PDF

Position Control of Direct Drive Brushless Motor using The Adaptive Variable Structure Control with Nonliner Switching Surfaces (비선형 적응 가변 구조 제어기를 가지는 브러쉬 없는 직접 구동형 서보 모터의 위치 제어에 관한 연구)

  • Lee, Dae-Sik;Lee, Sang-Oh
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.69-71
    • /
    • 1997
  • The direct drive motor is directly coupled by load. So, it is directly affected by load and disturbances. To control the direct drive motor, a robust controller is need. The main feature of variable structure system is that system trajectories are robust and insensitive to parameter variations and disturbances in the sliding mode. In this paper, adaptive variable structure controller, is used for the BLDD SM(Brushless Direct Drive Servo Motor) control. The chattering problem is reduced by using the saturation function.

  • PDF

A development of direct load control system for air-conditioner (원격제어 에어컨 개발 보급현황 및 향후전망)

  • Gang, Won-Gu;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF

Robust Time Delay Compensation for DTC-Based Induction Machine Systems via Extended State Observers

  • Wang, Fengxiang;Wang, Junxiao;Yu, Li
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.736-745
    • /
    • 2018
  • This paper presents an extended state observer (ESO) based direct torque control (DTC) for use in induction motor systems to handle the issues of time delays, load torque disturbances and parameter uncertainties. Direct torque control offers an excellent torque response and it does not require a proportion integration (PI) controller in the current loop. However, a PI controller is still adopted in the outer speed loop to generate the torque reference value, which is a slow method. An ESO based compound control scheme is proposed to improve the response rate and accuracy of the torque reference signal, especially when load torque is injected. In addition, the time delay problem is analyzed and compensated for in this paper to reduce torque ripples. The proposed disturbance compensation technique based direct control scheme is shown to have good performance both in the transient and stable states via simulations and experimental results.

Direct Load Control using Priority Based Dynamic Programming Technique (동적 프로그래밍 기법을 이용한 직접부하제어 알고리즘 개발)

  • Kim, Tae-Hyon;Lee, Jong-Soo;Shin, Myong-Chel;Choi, Sang-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.463-465
    • /
    • 2003
  • This paper adopts the methods of dynamic programming based on priority and the objective function is to maximize the amount of priority. The Purpose of this work is to schedule the direct load control with approciate constrints. To demonstrate the effectiveness of the study, sample data is used about 54 load. And the results of sample are described in this.

  • PDF