• Title/Summary/Keyword: Direct Current (DC)

Search Result 432, Processing Time 0.031 seconds

The study on the prevention of DC feeder line cable grounding fault (DC 급전케이블 지락사고 보호방안에 관한 연구)

  • Park, Ji-Soo;Song, Joong-Ho;Park, Joung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

A Study on Proposal and Necessity to Adopt the LVDC Standardization Policy (저압직류전기설비 표준화 정책 도입의 필요성 및 제안에 관한 연구)

  • Oh, Du-Seok;Kang, Seung-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.121-127
    • /
    • 2015
  • Recently, LVDC(Low Voltage Direct Current) has been came into the newly spotlight with HVDC(High Voltage Direct Current) and as increasing digital load, DC power supply and high quality of demand is also getting extended. In accordance with the report of EPRI(Electric Power Research Institute), they expect digital load will grow to 50% of whole load in 2020. Subsequently, the use of DC equipment will grow dramatically. Therefore, the careful adoption of LVDC standardization policy is urgently required for the safety of people, prevention of confusion and occupancy of the market.

Control Method for Fault-Tolerant Active Power Filters

  • Zhang, Chenyu;Zheng, Jianyong;Mei, Jun;Deng, Kai;Zhou, Fuju
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.796-805
    • /
    • 2015
  • New direct and indirect current control methods for a fault-tolerant active power filter topology are presented in this paper. Since a three-phase four-switch topology has a phase bridge current which cannot be directly controlled, a hysteresis control method in the α-β plane which controls the three-phase current in the two-phase stationary coordinate system is proposed. The improved SVPWM algorithm is able to eliminate the operation of the trigonometric functions in the traditional algorithm by rotating the α-β coordinates and alternating the sequence of the output vectors, which in turn simplifies the algorithm and reduces the switching frequency. The selection of the DC-side reference voltage and DC-side capacitor equalization strategy are also discussed. Simulation and experiments demonstrate that the proposed control method is correct and feasible.

Analysis of the Stray Current Conditions in Subway DC Electrification System (I) Seoul Metropolitan Area (지하철 직류 급전시스템의 표유전류 실태 분석(I) 서울 지역)

  • Ha Yoon-Cheol;Ha Tae-Hyun;Bae Jeong-Hyo;Kim Dae-Kyeong;Lee Hyun-Goo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1364-1366
    • /
    • 2004
  • When an underground pipeline runs parallel with DC-powered railways, it suffers from electrolytic corrosion caused by the stray current leaked from the railway negative returns. Perforation due to the electrolytic corrosion may bring about large-scale accidents even cathodically protected systems. Traditionally, bonding methods such as direct drainage, polarized drainage and forced drainage have been used in order to mitigate the damage on pipelines. In particular, the forced drainage method is widely adopted in Seoul. In this paper, we report the analysis of the stray current conditions in Seoul subway DC electrification system.

  • PDF

The electrical properties of in 18kV ZnO surge arrestor with mixed direct and 60Hz Alternating Voltage (중첩전압(직류 +60Hz 교류)에서 18kV 배전용 피뢰기의 전기적 특성)

  • Lee, Bok-Hee;Lee, Seung-Ju;Lee, Su-Bong;Jung, Dong-Cheol;Baek, Young-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.291-294
    • /
    • 2007
  • This paper preserts the characteristics of leakage currents flowing through 18 kV zinc oxide (ZnO) surge arrester under the mixed DC and AC voltages. The I-V curves of ZnO surge arrester were measured as a function of the voltage ratio K The I-V curves under the mixed DC and AC voltages lay between the pure DC and AC characteristics, and the cross-over phenomenon in I-V curves was observed at the low current region As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current th ZnO surge arrester.

  • PDF

Changes in the Sensory Function after Transcranial Direct Stimulation on Dorsolateral Prefrontal Cortex Area (배외측전전두엽피질 영역에 경두개직류전류자극이 감각기능에 미치는 영향)

  • Min, Dong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.445-452
    • /
    • 2015
  • Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers a low-intensity direct current to the cortical areas, thereby facilitating or inhibiting spontaneous neuronal activity. This study was designed to examine the changes in various sensory functions after tDCS. A single-center, single-blinded, randomized trial was conducted to determine the effect of a single session (August 4 to August 29) of tDCS with the current perception threshold (CPT) in 50 healthy volunteers. Nerve conduction studies (NCS) were performed in relation to the median sensory and motor nerves on the dominant hand to discriminate peripheral nerve lesions. The subjects received anodal tDCS with 1mA for 15 minutes under two different conditions, with 25 subjects in each group. The conditions were as follows: tDCS on the dorsolateral prefrontal cortex (DLPFC) and sham tDCS on DLPFC. The parameters of the CPT was recorded with a Neurometer$^{(R)}$ at frequencies of 2000, 250 and 5 Hz in the dominant index finger to assess the tactile sense, fast pain and slow pain, respectively. In the test to measure the CPT values of the DLPFC in the anodal tDCS group, the values increased significantly in all of 250 and 5 Hz. All CPT values decreased for the sham tDCS. These results showed that DLPFC anodal tDCS can modulate the sensory perception and pain thresholds in healthy adult volunteers. This study suggests that tDCS may be a useful strategy for treating central neurogenic pain in rehabilitation medicine.

Utility Interactive Photovoltaic Generation System Using Discontinuous Mode Buck-Boost Chopper (불연속모드 승강압초퍼를 이용한 계통연계형 태양광발전 시스템)

  • 김영철;이현우;서기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.325-331
    • /
    • 1999
  • In a utility interactive photovoltaic generation system. a PWM inverter is used for the connection between the p photovoltaic arrays and the utility. The dc current becomes pulsated when the conventional inverter system operates i in the continuous current mode and de current pulsation causes the distortion of the accurrent waveform. This paper p presents the reduced pulsation of de input current by operating the inverter with buck-boost chopper in the d discontinuous conduction mode. The dc current which contains harmonic component is analyzed by means of s separating into two terms of a ripple component and a direct component. The constant dc current without p pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provides a sinusoidal ac c current for domestic loads and the utility line with unity power factor.

  • PDF

A Decentralized Optimal Load Current Sharing Method for Power Line Loss Minimization in MT-HVDC Systems

  • Liu, Yiqi;Song, Wenlong;Li, Ningning;Bai, Linquan;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2315-2326
    • /
    • 2016
  • This paper discusses the elimination of DC voltage deviation and the enhancement of load current sharing accuracy in multi-terminal high voltage direct current (MT-HVDC) systems. In order to minimize the power line losses in different parallel network topologies and to insure the stable operation of systems, a decentralized control method based on a modified droop control is presented in this paper. Averaging the DC output voltage and averaging the output current of two neighboring converters are employed to reduce the congestion of the communication network in a control system, and the decentralized control method is implemented. By minimizing the power loss of the cable, the optimal load current sharing proportion is derived in order to achieve rational current sharing among different converters. The validity of the proposed method using a low bandwidth communication (LBC) network for different topologies is verified. The influence of the parameters of the power cable on the control system stability is analyzed in detail. Finally, transient response simulations and experiments are performed to demonstrate the feasibility of the proposed control strategy for a MT-HVDC system.

A Transimpedance Amplifier Employing a New DC Offset Cancellation Method for WCDMA/LTE Applications

  • Lee, Cheongmin;Kwon, Kuduck
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.825-831
    • /
    • 2016
  • In this paper, a transimpedance amplifier based on a new DC offset cancellation (DCOC) method is proposed for WCDMA/LTE applications. The proposed method applies a sample and hold mechanism to the conventional DCOC method with a DC feedback loop. It prevents the removal of information around the DC, so it avoids signal-to-noise ratio degradation. It also reduces area and power consumption. It was designed in a $0.13{\mu}m$ deep n-well CMOS technology and drew a maximum current of 1.58 mA from a 1.2 V supply voltage. It showed a transimpedance gain of $80dB{\Omega}$, an input-referred noise current lower than 0.9 pA/${\surd}$Hz, an out-of-band input-referred 3rd-order intercept point more than 9.5 dBm, and an output DC offset lower than 10 mV. Its area is $0.46mm{\times}0.48mm$.

A Study on the Characteristics for AC Corrosion of Gas Pipelines (가스배관의 교류부식 특성에 관한 연구)

  • Bae Jeong-Hyo,;Ha Tae-Hyun,;Lee Hyun-Goo,;Kim Dae-Kyeong,
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.29-35
    • /
    • 2001
  • Direct current corrosion have being investigated by lots of scientists but alternating current corrosion was ignored because the corrosion rate by AC was very small. Recently however, AC corrosion accidents have been reported in many other countries. So the study of AC corrosion is to be necessary In these days. In this paper, several experiments which intentionally imposed the AC or DC to the specimens also imposed AC and DC at the same time was carried out in the laboratory to examine the AC corrosion characteristics and in addition applied the same way in the field. Moreover, while the field investigations of the abnormal corrosion failures, It was the AC that caused one of corrosion failures.

  • PDF