• 제목/요약/키워드: Dipole-dipole resistivity survey

검색결과 77건 처리시간 0.029초

심부 석탄층 탐사에 있어서 CSAMT 탐사법 적용 (The Application of CSAMT to Deep-seated Coal Seams Exploration)

  • 정승환;김정호;전정수
    • 자원환경지질
    • /
    • 제23권1호
    • /
    • pp.73-79
    • /
    • 1990
  • Controlled source audio-frequency magnetotelluric (CSAMT) has the great advantage of efficient mapping resistivity distribution and relatively deep depth of investigation. Moreover, CSAMT may be regarded more attractive than audio-frequency magnetotelluric in the sense of the strong and controllable signal. However, it has the problem such as undershoot and/or near-field effect that is hard to be interpreted if the interpretation method of MT is directly applied. The problem arises from the existance of controlled source which makes CSAMT attractive. So the characteristics of CSAMT response should be thoroughly understood prior to interpretation stage. In this study, numerical modeling program for horizontally layered earth was developped for the interpretation of CSAMT field data. CSAMT field survey was run as a follow-up to resistivity dipole-dipole study over the same survey line at Bongmyung coal mine. The survey used a grounded dipole source 2 Km in length and located 7.5Km south in this study. A good agreement between field CSAMT data and calculated data was demonstrated even in geologically complex earth situations.

  • PDF

전기장 또는 자기장 송신원을 이용한 벡터 CSMT (Controlled Source Magnetotellurics with Vector Measurement Using Electric and Magnetic Sources)

  • 이희순;송윤호
    • 자원환경지질
    • /
    • 제30권5호
    • /
    • pp.451-458
    • /
    • 1997
  • The horizontal magnetic dipole as well as electrical dipole was adopted as a source to compute one-dimensional electromagnetic field behavior in controlled source magnetotellurics. he Cagniard impedances due to horizontal magnetic dipole source, especially phases, showed better frequency characteristics than those due to electric one. The magnetic dipole is inferior to the electric dipole in the point of relatively weak transmitting power at low frequency. But considering high resistivity charateristics of Korean geology, the magnetic dipole source is recommended for the survey up to depth of 500 m. A vector CSMT was introduced to get more reliable data in the area of two- or three-dimensional structures. A software and interpretation technique using polarization ellipses were developed. The technique was tested by synthetic data, which provided theoretical basis of the methodology. Although CSMT has inevitable limitation of investigation depth due to practically possible source-receiver separation, we proposed to use the technique developed in this paper where MT is not available, for example, in extremely noisy area or for shallow target.

  • PDF

전기비저항(電氣比抵抗) 탐사(探査)에 의한 포항분지(浦項盆地)와 장기분지의 경계규명(境界糾明) (Investigation of Boundary between Pohang and Janggi Basins by Electrical Resistivity Survey)

  • 민경덕;윤혜수;문희수;이현구;이대하
    • 자원환경지질
    • /
    • 제23권2호
    • /
    • pp.215-219
    • /
    • 1990
  • Geological and electrical resistivity surveys along the survey line of about 3 km between Kyungsangbukdo Youngilgun Hodong and Gwangmyungdong using by dipole-dipole electrode array method were carried out to examine the boundary and structural relationship between Tertiary Pohang and Janggi basins. Electrical resistivity data were interpreted qualitatively and quantitatively by means of pseudosection of apparent electrical resitivity distribution and finite difference method for two dimensional geologic structure model. The nearly vertical fault zone with low electrical resistivity value of 1-5 Ohm-m and widths of about 200m at the surface and 400 m at depth exists around 1.2 km west of national road between Ocheoneup and Yangbukmyun. Mudrocks, sandstones and tuffaceous rocks are widely distributed with electrical resistivity values of 6-77 Ohm-m. Especially, tuffaceous rocks with relatively high electrical resistivity value are predominant at eastern side of fault zone. Consequently, it is known that Pohang and Janggi basins are in fault contact.

  • PDF

옥천대(沃川帶)의 지질(地質) 및 광물자원(鑛物資原)에 관(關)한 연구(硏究) -봉화재 지역(地域)에 대(對)한 전기비저항탐사(電氣比抵抗探査)- (Electrical Resistivity Survey on the Geolgical Structure of the Bonghwajae Area in the Okchon Zone)

  • 민경덕;김창렬;윤춘성;정승환
    • 자원환경지질
    • /
    • 제21권2호
    • /
    • pp.131-137
    • /
    • 1988
  • Geological and electrical resistivity surveys were carried out to investigate subsurface geology and geologic structure of the Bonghwajae area in the Okchon zone. Pseudosections of the apparent electrical resistivity distribution along the three survey lines were obtained by using dipole-dipole electrode array method, and models of subsurface geology and geologic structure by using two dimensional finite difference method. The Bonghwajae fault zone exists around Bonghwajae area in the north-south direction, and is a boundary between Okchon Group and Choson Supper Group. Metabasite and hornblende gabbro intruded along the Bonghwajae fault zone remaining two fracture zones with low resistivity value of 20 ohm-m and widths of about 100m and 70-300m. They strike nearly N-S and dip westward with a high angle of $60-70^{\circ}$. Sochangri fault with a width of about 160m exists between Jisogori and Bonghwajae, by which Bonghwajae fault zone is displaced about 1km in the east-west direction. Hornblende gabbro whose electrical resistivity value is in the range of 5000-8000 ohm-m intruded the metabasite of 2000-4500 ohm-m after the Sochangri fault had formed. Great Limestone Group is widely distributed in the east of Bonghwajae fault zone, and interbeds so called Yongam formation of graphitic black slate with an extremely low electrical resistivity value of 2 ohm-m.

  • PDF

의성 탑리리 오층석탑 기단부 전기비저항 탐사 (Resistivity Survey on Stylobate of Five-story Stone Pagoda in Tamni-ri, Uiseong)

  • 오현덕;권문희
    • 지구물리와물리탐사
    • /
    • 제23권4호
    • /
    • pp.253-260
    • /
    • 2020
  • 경상북도 의성군 탑리리 오층석탑은 상부구조가 불안정하고 지대석과 기단부의 구조적 변형이 심각한 상태였다. 탑의 기단부 보수공사를 위해서 기단 내부에 석재가 존재하는지를 파악하여 탑을 안전하게 받치고 있는지를 조사하기 위하여 전기비저항 탐사를 실시하였다. 탑의 기단부는 면석을 모두 제거하여 흙과 깬 돌이 노출된 상태이다. 사용한 전극 배열법은 쌍극자 간격을 다변화시킨 변형된 홑극-쌍극자 배열법 II를 사용하였으며 일반적인 홑극-쌍극자 배열법과 함께 사용하여 비교 분석하였다. 그리고 이 연구에서는 직각측선과 같은 심한 지형기복에 의한 왜곡현상을 포함하는 데이터의 신뢰도 검사를 위하여 축소모형실험을 수행하였다. 탐사결과 의성 탑리리 오층석탑의 기단부는 보강 채움 토 내부에 기초석이 존재하고 탑신의 기둥 직하부에 위치하여 탑을 받치고 있는 것을 확인하였다.

난지도 매립장의 안정화에 따른 지질환경 변화 조사를 위한 지구물리 탐사 (Geophysical Investigation of the change of geological environment of the Nanjido Landfill due to the Stabilization Process)

  • 이기화;권병두;임형래;양준모
    • 지구물리
    • /
    • 제3권2호
    • /
    • pp.113-126
    • /
    • 2000
  • 난지도 매립장의 안정화에 따른 지질환경 변화를 조사하기 위하여 탐사가 가능한 제 2 매립장 상부와 한강변에 연한 매립지의 기저지역에서 중력, 자력, 쌍극자-쌍극자, 자연전위 탐사를 수행하였다. 제 2 매립장 상부에서 수행한 중력과 자력 탐사 결과를 4 년전의 선행연구 결과와 비교하면 매립장 중앙 부분에서 밀도구배가 작아지고 복잡한 양상을 보였던 자력이상 분포가 많이 단순해진 것으로 나타난다. 이는 매립지의 안정화과정에서 침하와 복토작업이 반복되면서 매립물의 다짐작용이 순조롭게 진행되고 있는 것으로 보인다. 제 1 매립장 차수벽 밖에서 실시한 쌍극자-쌍극자 전기탐사와 자연전위탐사 결과에는 제 1 매립장 주위의 불량한 탐사환경에 의한 영향이 많이 나타난다. 제 2 매립장의 차수벽 안과 밖에서 실시한 쌍극자-쌍극자 전기탐사 결과를 비교하면 차수벽이 침출수를 어느 정도 차단하는 효과를 볼 수 있다. 제 2 매립장의 상부와 사면에서 수행한 자연전위탐사에서는 특별한 자연전위 이상은 나타나지 않으나, 하부의 차수벽 내부에서 수행한 자연전위 탐사 결과에는 침출수를 모으는 집수정의 영향이 크게 나타난다.

  • PDF

변형 쌍극자배열법을 적용한 울릉도 나리 칼데라 주변 조면안산암 지역의 비저항분포 특성 분석 (Distribution of Resistivity Zones Near Nari Caldera, Ulleung-do, Korea, Inferred from Modified Dipole Arrays)

  • 김기범;김만일
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.223-236
    • /
    • 2019
  • 전기비저항탐사는 지질 분포나 단층 파쇄대의 유무 등의 지질 구조, 지층의 풍화 및 변질 정도, 지하수 등을 파악하기 위하여 광범위하게 활용되는 탐사기법이다. 본 연구에서는 지하 전기비저항의 분포특성을 분석하기 위하여 총 6개 측선을 중심으로 울릉도 나리분지와 알봉분지 주변 지하 칼데라 퇴적층과 지질 구조를 파악하기 위하여 기존의 쌍극자배열법(A 방법과 C 방법)의 탐사결과와 함께 변형된 쌍극자배열법(D 방법)을 적용하여 연구를 수행하였다. 본 연구결과, 변형된 쌍극자배열법을 적용하여 최적의 지하 비저항 분포단면 분석을 통해 퇴적층과 연약대가 분포하는 구간인 500 ohm-m 이하의 저비저항대와 화산암체인 조면안산암질 암류가 분포하는 5,000 ohm-m 이상의 고비저항대의 경계를 명확하게 파악할 수 있었다. 알봉분지의 퇴적층은 평균 50~100m 내외, 나리분지의 퇴적층은 평균 약 100~200m 내외의 두께로 분포하는 것으로 추정되며, 칼데라 단층으로 추정되는 이상대는 지표부근에서 탐사심도 하부까지 500 ohm-m 이하의 저비저항대가 수직으로 연장성을 가지면서 암반 내 연약대와 구분되는 것으로 분석되었다.

포항 옥명 폐기물 매립장에서의 전기탐사 (Electrical surveys at the Okmyung waste landfill of Pohang)

  • 이기화;윤종렬
    • 지구물리
    • /
    • 제1권1호
    • /
    • pp.41-50
    • /
    • 1998
  • 포항 옥명 폐기물 매립장과 매립장 입구 전방지역에서 1997년 8월과 1998년 1월에 걸쳐 슐럼버져 전기비저항 수직탐사, 쌍극자 비저항탐사 및 전자기 유도방식을 이용한 전기전도도 수평탐사를 실시하였다. 전기비저항 수직탐사는 매립장 내부와 매립장 입구 전방지역에서 11점과 4점이 실시되었으며, 쌍극자 비저항탐사도 각각 1측선씩 실시되었다. 또한 전기전도도 수평탐사는 총 164점이 4개의 측선을 따라 매립장 입구 전방지역에서 수행되었다. 자료의 해석결과 제 6매립장에서는 0.3∼3 Ωm의 저비저항대가 지표하 65 m까지 나타나고 있어 하부지층의 침출수에 의한 오염가능성을 시사하고 있으며, 예상 침출수위는 지표하 3∼6 m로 추정되었다. 제 9매립장은 2 Ωm이하의 저비저항대가 지표하 11∼15 m까지 나타나고 있어 하부지층의 오염가능성은 없는 것으로 판단된다. 한편 매립장 입구 전방지역에서는 비저항 탐사자료나 전기전도도 수평탐사 자료 모두 천부의 비저항값이 낮게 나타나 이 지역에서는 풍화대의 오염가능성이 매우 큰 것으로 생각된다. 또한 같은 지역내에서도 제 6매립장이 가까이 위치하는 남쪽지역이 침출수의 영향을 더욱 많이 받는 것으로 나타났다.

  • PDF

전기비저항 토모그래피를 이용한 저수지 제체 그라우팅 효과 검증 (Verification of Reinforcement with Grouting Materials in Reservoir Dike using Electrical Resistivity Tomography)

  • 송성호;용환호;이규상;우명하
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.73-78
    • /
    • 2006
  • 저수지 누수구간에 대한 지수를 목적으로 저수지 제체를 대상으로 시멘트 그라우트를 이용한 그라우팅을 수행하였으며, 효과 검증을 위하여 그라우팅 전후에 다양한 수리시험과 전기비저항 탐사를 수행하였다. 효과 검증을 위한 쌍극자배열 전기비저항 탐사 결과 그라우팅 이후 전극 전개별 겉보기 비저항 이상곡선이 양호한 연속성과 주입 구간 전체에서 저비저항대가 수평적으로 발달되는 결과가 나타났다. 또한 장기간의 전기비저항 수직탐사를 이용한 결과 겉보기 비저항을 이용하는 경우 주입 이전에 비해 낮아지는 구간으로 주입 구간 확인이 가능하였다. 검사공을 이용한 전기비저항 토모그래피 탐사 결과 제체 상부에서 수행한 기존의 탐사 결과와 일치됨에 따라 향후 검사공을 이용한 그 라우팅 효과 판정 시 이 방법을 병행하는 경우 제체의 그라우팅 효과에 대한 공간적인 검증이 가능함을 확인하였다.

  • PDF

비저항 측선 근처 철케이싱 시추공 한개에 의한 $-{\rho}a$ ($-{\rho}a$ by One Steel Casing Borehole near Resistivity Survey Line)

  • 정현기
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.83-86
    • /
    • 2006
  • 쌍극자 전기탐사현장에서 드물지않은 음의 겉보기비저항에 대해 선진 장비회사의 메뉴얼들에서 언급되되 정확한 현상이 규명 안되었으나, 국내에서 계측 측면 및 가능한 지질모델 제시와 함께 전산모델링 결과와 $-{\rho}a$ 포함유무 3차원 역산결과가 일부 보고된 바 있다. 전도성 탄층, 전봇대 접지, 신호등, 철케이싱 시추공 등과 관련한 현장문제가 계속되어 해석시 딜레마 극복 지침이 필요하다. 여기서는 단순 철케이싱 한개의 효과 전산 모델링 결과 및 일부 측선 설계요령과 해석시 유의사항을 고찰한다. $-{\rho}a$는 분명한 지하정보이지만 잘못 해석시 진실과 먼 결과 오류 가능성이 높으며, 향후 역산 알고리즘의 유용한 발전이 절실하다.

  • PDF