• Title/Summary/Keyword: Dipole-dipole Array

Search Result 163, Processing Time 0.025 seconds

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Distribution of Resistivity Zones Near Nari Caldera, Ulleung-do, Korea, Inferred from Modified Dipole Arrays (변형 쌍극자배열법을 적용한 울릉도 나리 칼데라 주변 조면안산암 지역의 비저항분포 특성 분석)

  • Kim, Ki-Beom;Kim, Man-Il
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.223-236
    • /
    • 2019
  • Resistivity surveys can identify the distribution of geological units and structures (including fragmented fault zones), the extent of weathered and modified geological strata, and the characteristics of groundwater. This study aims to analyze the underground sedimentary layers and geological structures near the Nari and Albong Basins of Ulleung-do, Korea, focusing on six survey lines to identify the spatial trends in subsurface resistivity. A modified dipole array method (D method) was employed, combining resistivity results obtained by existing dipole array methods (A and C methods). The modified method provides optimal analysis of the cross-section of underground resistivity, and shows a clear boundary between a low-resistivity zone (${\leq}500{\Omega}{\cdot}m$) of sedimentary layers and weak zones, and a high-resistivity zone (${\geq}5,000{\Omega}{\cdot}m$) of volcanic rock (trachyandesite). The estimated average thickness of the sedimentary layers is 50~100 m for the Albong Basin and 100~200 m for the Nari Basin. An anomaly zone, different from the weak zone in the bedrock, is identified as a caldera fault, and the low-resistivity zone extends from the surface down to the lowest survey depths.

A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone (취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구)

  • Park, Samgyu;Kim, Jaehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.5-13
    • /
    • 2013
  • The water leakage of reservoir embankment usually occurs around channelling pipes, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain and the rainy season in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disaster prevention and embankment maintenance. The water leakage in dams and levees where the channelling pipes are working as weak zone was analyzed by using both numerical simulation and experimental method in this study. To detect the water leakage, an electrical resistivity survey was used and investigated for its' usability. The numerical results show the size and location of weak zone increases the importance of selection of electrode spacing. The leakage experiments of model embankment present the best result is obtained under the conditions of electrode spacing of 0.3m and dipole-dipole array. By studying the water leakage in dams and levees, the electrical resistivity survey is observed it is a very useful method to predict the leakage.

Interpretation of shallow geological structure by applying GIS to geophysical data (물리탐사자료의 GIS 복합처리에 의한 천부지질구조 해석)

  • 송성호;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.123-126
    • /
    • 1998
  • We have conducted surface electrical resistivity surveys along with the electrical logging at Bookil-Myun, Chungwon-Goon, Choongchungbuk-Do to determine the depths of basement and water table, and for the purpose of preparing the basic input data for hydrogeologic model combined with GIS. A twenty lines of dipole-dipole array survey and a twenty-five stations of resistivity sounding were performed and ten holes were employed for electrical logging to cross check the surface data. A combined interpretation gave the quantitative information of the shallow geologic structure over the area and we constructed layers using the grid analysis of Arc/info. The constructed layers were turned out to be similar to the geologic structure confirmed from the drilling data and we concluded that the methodology adopted in this study would be applicable to hydrogeologic model setup as a tool of providing the basic input data.

  • PDF

Interference effect by underground utilities at electric resistivity Survey (전기비저항 탐사시 지하매설물에 의한 간섭효과 연구)

  • Kim, Jae-Hong;Oh, Byung-Hyun;Im, En-Sang;Lee, Jong-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.961-965
    • /
    • 2009
  • Using much electric resistivity survey to design or preservation administration of facilities. However, By survey method that electric resistivity survey grasps special quality in base by potential difference creating artificial current in underground, Is influenced in electric resistance propensitys of various underground utilities in base. This Study selects dam 1 place that could grasp well underground situation and studied electricity interference effect by effect of underground utilities. Grasp underground utilities of dam interior, and control and observed accuracy with survey wave because various pole space. Through this Study, wish to present survey method of electric resistivity survey at design or survey of preservation administration dimension after with drawn result.

  • PDF

Comparison of electrode arrays for earth resistivity image reconstruction of vertical multi layers (수직 다층구조의 대지저항률 영상복원을 위한 전극배열법의 비교)

  • Boo, Chang-Jin;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of IKEEE
    • /
    • v.22 no.1
    • /
    • pp.149-155
    • /
    • 2018
  • In this paper, we used ET(Electrical Tomography) for earth resistivity image reconstruction of vertical multi layer underground model. The earth resistivity is analyzed generally as the parallel multi-layer model, however possibly there happens vertical layer model. Here to find the best electrode array in case of vertical layer underground model, Wenner, Schlumberger, and Dipole-dipole electrode arrays, which are well known electrode arrays used in ET, have been tested. And Gauss-Newton algorithm is used in ET inversion. RMS error analysis shows that Wenner electrode array is best in imaging.

Small ESPAR Antenna with 180 Degree Azimuth Beam Coverage (180도 방위 빔 커버리지 특성을 갖는 UNII대역 소형 전자 빔 조향 기생 배열 안테나)

  • Choi, Ik-Guen;Ju, Sang-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.11-16
    • /
    • 2010
  • In this papar, we have proposed a small electronically steerable parasitic array radiator with 180 degree azimuth beam coverage and high gain characteristics. The proposed antenna is composed of a uniplanar Yagi dipole as a feeding element and two dipoles as parasitic elements. The fabricated antenna is tested by electronically changing the reactance loaded on the parasitic dipoles and the results show that it has 5.2dB~6.7dB gain in $-90^{\circ}{\sim}90^{\circ}$wide azimuth range and -10dB return loss characteristics within 5.725GHz~5.825GHz UNII band.

Investigation of fault in the Kyungju Kaekok-ri area by 2-D Electrical Resistivity Survey (2차원 전기비저항 탐사를 이용한 경주 개곡리 지역의 단층조사)

  • Lee, Chi-Seop;Kim, Hee-Joon;Kong, Young-Sae;Lee, Jung-Mo;Chang, Tae-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.124-132
    • /
    • 2001
  • Electrical resistivity survey has been conducted for delineating geological fault structure in Kaekok-ri near Kyungju. In general, electrical resistivity survey has an advantage of searching buried faults and its traces compared with other geophysical survey methods. Distribution of electrical conductivity in the ground is influenced by the ratio of pores, groundwater and clay minerals. These properties are evidenced indirectly to explain for weathering condition, faults and fracture Bones. Thus the electrical resistivity survey can be an effective method to find buried faults. We have carried out two dimensional (2-D) interpretation by means of smoothness-constrained least-squares and finite element method. Field data used in this paper was acquired at Kaekok-ri, Wuedong-eup, Kyungju-si, where is Ulsan Fault and is close to the region in which debatable quaternary fault traces were found recently. The dipole-dipole array resistivity survey which could show the 2-D subsurface electrical resistivity structure, was carried out in the area with three lines. The results showed good property of fault, fracture zone and fault traces which we estimated were congruous with the results. Through this study, 2-D electrical resistivity survey interpretation for fault is useful to apply.

  • PDF

A Study on the Leachate Distribution of the Mooreung Landfill Site with Electrical Resistivity Surveys (전기비저항 탐사를 이용한 충주 무릉매립장 침출수 분포에 관한 연구)

  • Kim, Jun-Kyoung
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.455-463
    • /
    • 2006
  • The electrical resistivity prospecting method with dipole-dipole array was applied to the Mooreung landfill site in order to survey the existence of leachate around the landfill site. Moreover, if there is leachate within Mooreung landfill site, the analysis of potential pathways to exterior environments was tried. Within the landfill site, the over-all characteristics of the electrical resistivity anomalies suggest that the leachate induced from the landfill materials has infiltrated the basement rock and fill the pores of basement rock in some parts of the landfill site. The consistency of the anomaly locations (left part of each survey line), anomaly geometries, and absolute resistivity value of anomaly through the 3 survey lines suggests that the resistivity anomaly be connected from the upstream to the downstream and correspond to the leachate material. Finally, the result from the electrical resistivity survey line near the gateway of the landfill site suggests that some of the leachate induced from landfill material leaks to the exterior groundwater system. It is necessary that more surveys using both geochemical and geophysical methods should be performed to find out potential pathways and depths of the leachate more precisely.

An Omnidirectional High Gain Antenna for UHF Band Ground Station (UHF대역 지상국용 무지향 고이득 안테나)

  • Bae, Ki-Hyoung;Chang, Min-Soo;Joo, Jae-Woo;Hwang, Chan-Ho;Hong, Ki-Pyo
    • Journal of the Korea Knowledge Information Technology Society
    • /
    • v.12 no.4
    • /
    • pp.539-550
    • /
    • 2017
  • In this paper, we designed, fabricated and tested an UHF band cylindrical dipole array antenna. In the proposed antenna, cylindrical dipoles were vertically arranged in four stages. A parallel structure feeding circuit was installed inside the cylindrical dipole and mounted so as to be broadband matching. The feeding circuit was installed at the center of the cylindrical dipole to optimize the gain flatness characteristic of the azimuth direction omnidirectional radiation pattern. Minimizing the difference between the signals branched from the feeding circuit and realizing the symmetry of the radiation pattern. The required specifications are more than 11.2% bandwidth in UHF band, above 6dBi antenna gain, standing wave ratio of 2:1 or less, less than ${\pm}1dB$ gain flatness in azimuth radiation pattern, more than 13 degrees in elevation radiation pattern of 3dB beamwidth. We confirmed the possibility of implementation through M&S and verified the result of M&S through production and testing. The test results are 11.2% bandwidth in the UHF band, 6.30 to 8.31 dBi gain, 1.53:1 standing wave ratio or less, within ${\pm}0.2dB$ gain flatness in the azimuth radiation pattern, elevation radiation pattern of 3dB beam width was 15.62 to 15.84 degrees. The test result meets all requirements specifications.