• Title/Summary/Keyword: Dip

Search Result 1,377, Processing Time 0.027 seconds

A study on the preparation of ${alpha}-Fe_2O_3$films by dip-coating method (Dip-coating법에 의한 ${alpha}-Fe_2O_3$막 제조에 관한 연구)

  • 강경원;정용선;현부성;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.292-298
    • /
    • 1998
  • ${\alpha}-Fe_2O_3$films were prepared by a dip-coating method using the mixed solution of ferric nitrate, ethylene glycol and acethyl acetone. The polymerization effect of the mixed solution was studied by FT-IR spectroscopic analysis, and the decomposition of organic parts and crystallization of the dip-coated film were investigated by FT-IR, XRD and DSC. In addition, AFM and SEM were employed to analyze the surface roughness and the thickness of ${\alpha}-Fe_2O_3$films.

  • PDF

Water quality management of Jeiu Harbor using material cycle model(III) - Quantitative Management of Pollutant Loadings - (물질순환모델을 이용한 제주항의 수질관리(III) - 오염부하의 정량적 관리 -)

  • 조은일;강기봉
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.307-317
    • /
    • 2003
  • In this study, the material cycle model was applied to suggest alternative management of water quality for Jeju Harbor. The distribution of COD, DIN (dissolved inorganic nitrogen) and DIP (dissolved inorganic phosphorus) concentrations was reasonably reproduced by simulations on the model area of the Jeju Harbor using a material cycle model. The simulations of COD, DIN and DIP concentrations were performed under the conditions of 20∼100% pollution loadings reductions from pollution sources. In case of the 100% reduction of the input loads from Sanzi river, concentrations of COD, DM and DIP were reduced to 39%, 78% and 52%, respectively at Jeju harbor. In contrast, in case of the pollutant loadings reductions from sediment, the effect of DIN and DIP reduction relatively seemed to increase around the center of study area. The 95% reduction of the pollutant loadings from river and sediment is required to meet the COD and nutrients concentration of second grade of ocean water quality criteria.

Stability dip, the obstacle of early loading protocol, how can it be figured out? (임상가를 위한 특집 2 - Early loading의 난제 stability dip, 어떻게 극복할 것인가?)

  • Park, Chang-Joo
    • The Journal of the Korean dental association
    • /
    • v.51 no.4
    • /
    • pp.198-203
    • /
    • 2013
  • Nowadays, it seems like that the concept of the early loading protocol has been intruded between the concept of the immediate loading supported by advanced clinicians and the concept of the conventional loading supported by the prudent clinicians. In particular, the stability dip, which is found to occur usually at 4~6 weeks after dental implant placement because the decrease of the primary mechanical stability is not compensated by the increase of the secondary biologic stability, is frequently pointed out as one of the major causes of early loading failure. In this article, based on our recent clinical investigation about the crestal bone preservation effect of the early loaded NanoTite$^{TM}$ Tapered Certain Prevail$^{(R)}$ (Biomet 3i, USA), the concept of the early loading is revisited. In addition, various methods to overcome the stability dip are reviewed as the oral and maxillofacial surgeon's view point.

Regional Evaluation of Slope Stability by Using GIS and Geostatistics Around the Southern Area of Chungju Lake (GIS와 지구통계학을 이용한 충주호 남부지역의 광역적인 사면안정평가)

  • 문상기
    • Economic and Environmental Geology
    • /
    • v.33 no.2
    • /
    • pp.117-128
    • /
    • 2000
  • Regional evaluations of slope stability by the failure criterion and by environmental geological factors were conducted. The failure criterion is the general conditions for plane failure which consider the geometrical conditions between geological discontinuities and topographical slope planes. The factor focused in this condiction is dip and dip direction. Geostatics, named semivariogram was used for establishing structural domains in slope stability evaluation by the failure criterion. The influential range was calculated to 6 km in the case of dip direction of dominant joint set and 7 km in the case of dip of the same dominant joint set. Then applying this failure criterion to the study area produced a slope stability map using the established domains and slopes generated by TIN module of ARC/INFO GIS. This study considered another regional slope stability analysis. 5 failure-driven factors 9the unstable slope map, geology, engineering soil, groundwater, and lineament density) were selected and used as data coverages for regional slope stability evaluation by geoenvironmental factors. These factors were weighted and overlayed in GIS. From the graph of cumulatave area (%) and instability index, finding critical points classified the instability indices. The most unstable slopes are located in the southern area of Mt. Eorae, Dabul-ri, and the eastern area of Junkok-ri in the first area is plane failure. Also, the expected orientations of failure are 59/338 and 86/090 (dip/dip direction).

  • PDF

Comparison of Water Quality According to Seasonal Variation in Mokpo and Wando Costal Areas

  • Kim, Woo-Hang;Lee, Young-Sik
    • Journal of Environmental Science International
    • /
    • v.17 no.3
    • /
    • pp.269-273
    • /
    • 2008
  • The objective of this study was to evaluate the relationship between nutrients and phytoplankton. This study was done by the comparison to two costal areas Mokpo, which inflow fresh water, and Wando. In August, salinity of the sea water decreased by 3.5-4.5%o in Mokpo coastal area, but was not nearly decreased in Wando coastal area. This suggests a lot of fresh water inflow in Mokpo coastal area. DIN and DIP were decreased by water temperature increasing in Wando. However, in Mokpo, DIN and DIP were increased greatly during the summer season. Nitrogen was limited to a 10 NIP ratio especially during the summer season in Wando coastal area while phosphorus in Mokpo coastal area was limited with over 28 N/P ratio in all the seasons. Coefficient of determination$(r^2)$ between DIP and Chl.-a was 0.91 in Mokpo coastal area. On the other hand, Coefficient of determination$(r^2)$ between Chl.-a and DIN, DIP were 0.93 and 0.89, respectively, in Wando coastal area. These results suggest DIP in Mokpo and DIN and DIP in Wando might be limited at the increase of phytoplankton.

Study of Tunnel Face Mapping Using Tunnel Mapper (Tunnel Mapper를 이용한 Tunnel 막장면 조사에 관한 연구)

  • Kwak, No-Kyung;Cho, Sung-Jin;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.200-211
    • /
    • 2010
  • Tunnel Mapper, which is tunnel face survey system was used to conduct Face Mapping on the face of the tunnel that is under construction. Then, accuracy and utility value on the forecast of discontinuity were verified to verify the field application in order to present the measures for the use of the system for conducting research on the discontinuity. As result of the directivity verification following discontinuity‘s project, forecasted measurement and actually researched measurement error for the Dip direction and Dip angle was less than ${\pm}10$. Accuracy was 82.6% for Dip direction and 90.7% for Dip angle, which are high. Accordingly, face research discontinuity forecasting system's reliability level towards directivity is high. Tunnel Mapper, a tunnel face survey system can be leveraged to replace face's visual survey and to obtain objective information, enabling execution of the survey system that can automate face survey going beyond time and space related limitations.

  • PDF

A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network (한국전력 노후 가공송전선의 동적송전용량에 대한 재평가)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.123-129
    • /
    • 2010
  • During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

Material Budgets in the Youngsan River Estuary with Simple Box Model (영산강 하구해역에서의 단순 박스모델에 의한 물질수지)

  • Lee, Kyeong-Sig;Jun, Sue-Kyung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.248-254
    • /
    • 2009
  • Budgets of fresh water, salt, DIP and DIN in the Youngsan river estuary were estimated seasonally in order to clarify the characteristics of material cycling and flux of nutrients with a simple box model. Inflow volumes of freshwater into system was approximately $36.481{\times}10^6{\sim}663.634{\times}10^6m^3/month$ and existing water mass of freshwater in system calculated by salt budget was approximately $2.515{\times}10^6{\sim}5.812{\times}10^6m^3$. Mean residence time of freshwater was calculated to be about 0.26~2.03 day. water exchange $1,248{\times}10^6{\sim}9,489{\times}10^6m^3/month$ assumed with salinity between estuary and adjacent ocean. Inflow mass of DIN and DIN were approximately 76.63~1,149.91 ton/month and 2.91~61.22 ton/month, respectively. Residence times of DIP and DIN were calculated to be 0.45~1.10 day and 0.28~1.92 day, respectively. The ratio of water residence time versus DIP, DIN residence time was calculated that freshwater residence time was longer than DIP, DIN residence time except for summer season. Thus, We assume that circulation of Nutrients in the system will happen rapidly except for summer season. Specially DIP in Winter could assume to outer input source existence because of seawater inflow in system and high DIP concentration in open sea.

  • PDF

The Architecture and Its Function of Tool server in MPEG-21 Multimedia Framework (MPEG-21 멀티미디어 프레임워크에서 툴 서버의 구조 및 기능)

  • 김광용;홍진우;김진웅
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.292-295
    • /
    • 2003
  • This paper presents the architecture and its function of Tool server. MPEG-21 will enable all-electronic creation, delivery and trade of digital multimedia content and transparent usage of various content types on network device. Therefore, we can provide access to information and services from almost anywhere at anytime with various terminals and networks. In order to support multimedia delivery chain that contains content creation, production, delivery and consumption, we need some elements to identify, describe, manage and protect the contents. Thus, we define Digital Item Processing(DIP), Digital Item Adaptation(DIA) server and Tool server as primary objects of MPEG-21 multimedia framework. DIP provides a function which creates and consumes Digital Item(DI) as a kind of a digital object by user. DIA server adapts the original DI to the usage environment description sent from the terminal and transmits the adapted DI to the terminal. Tool sewer searches for a tool requested from DIP or DIA and downloads the best tool to DIP or DIA server. In this paper, we present how Tool server is organized and is used among 2 primary objects. The paper is structured as following: Section 1 briefly describes why MPEG-21 is needed and what MPEG-21 wants. We see the basic architecture of tool server and its functionality by each module in section 2. Section 3 explains a scenario that tool server transmits tool to DIP or DIA. The paper concludes in section 4.

  • PDF

Fabrication of Polypyrrole Deposited Poly (vinyl alcohol) Nanofiber Webs by Dip-coating and In situ Polymerization and their Application to Textile Electrode Sensors (Polypyrrole을 증착시킨 Poly(vinyl alcohol) 나노섬유 제조 및 전극용 텍스타일 센서로의 활용 가능성 탐색 -딥 코팅과 현장중합 증착 방식을 중심으로-)

  • Yang, Hyukjoo;Kim, Jaehyun;Lee, Seungsin;Cho, Gilsoo
    • Fashion & Textile Research Journal
    • /
    • v.22 no.3
    • /
    • pp.386-398
    • /
    • 2020
  • This study compared dip-coating and in situ polymerization methods for the development of nanofiber-based E-textile using polypyrrole. Nanofiber webs were fabricated by electrospinning an aqueous poly (vinyl alcohol) (PVA) solution. Subsequently, the PVA nanofiber web underwent thermal treatment to improve water resistance. Dip-coating and in situ polymerization methods were used to deposit polypyrrole on the surfaces of the nanofiber web. An FE-SEM analysis was also conducted to examine specimen surface characteristics along with EDS and FT-IR that analyzed the chemical bonding between polypyrrole and specimens. The line resistance and sheet resistance of the treated specimens were measured. Finally, an electrocardiogram (ECG) was measured with textile sensors made of the polypyrrole-deposited PVA nanofiber webs. The polypyrrole-deposited PVA nanofiber webs fabricated by dip-coating dissolved in the dip-coating solution and indicated damage to the nanofibers. However, in the case of in situ polymerization, polypyrrole nanoparticles were deposited on the surface and inter-web structure of the PVA nanofiber web. The resistance measurements indicated that polypyrrole-deposited PVA nanofiber webs fabricated by in situ polymerization with an average sheet resistance of 5.3 k(Ω/□). Polypyrrole-deposited PVA nanofiber webs fabricated by dip-coating showed an average sheet resistance of 57.3 k(Ω/□). Polypyrrole-deposited PVA nanofibers fabricated by in situ polymerization showed a lower line and sheet resistance; in addition, they detected the electrical activity of the heart during ECG measurements. The electrodes made from polypyrrole-deposited PVA nanofiber webs by in situ polymerization showed the best performance for sensing ECG signals among the evaluated specimens.