• 제목/요약/키워드: Diode Detector

검색결과 280건 처리시간 0.034초

LOC 형광검출 소자를 위한 광 다이오드의 제작 및 특성 평가 (Development of Photo-diode for LOC fluorescence detector)

  • 김주환;신경식;김용국;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.100-103
    • /
    • 2003
  • Signal detection technologies such as fluorescence, charge and electrochemical detection used in the monolithic capillary electrophoresis system to convert the biochemical reaction into the electrical signal. The fluorescence detection using photodiodes that measure fluorescence emitted from eluting molecules is widely used for the monolithic capillary electrophoresis system. In this paper, in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive$(4k{\Omega}{\cdot}cm)$ wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571{\Omega}$ to $393{\Omega}$.

  • PDF

치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구 (A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation)

  • 이동훈;권장우;홍승홍
    • 센서학회지
    • /
    • 제5권5호
    • /
    • pp.11-20
    • /
    • 1996
  • 본 연구에서는 가속기에서 발생하는 치료방사선을 방사선원으로 사용하여 다이오드 치료방사선 검출센서의 특성을 조사하였다. 방사선량에 따른 선형성, 재현성, 오차율, 에너지의존성, 방사선조사후의 감도변화량, 다이오드의 숫자에 따른 출력값 측정 및 Portal 영상을 위한 가능성 검사를 위해서 핵계측기를 이용한 펄스 성형(成形)을 시도하였다. 제작된 시스템의 효율성을 검증하기 위하여 구성된 다이오드 센서로 조사야(照射野)별 심부량(深部量)를 백분율을 기존의 측정장치인 기체 전리함을 이용한 값과 상호 비교하여 보았다. 또한 다이오드의 선량측정회로를 다채널로 구성하여 A/D 변환후 컴퓨터 상에서 치료영역의 범위를 읽을 수 있었다. 모형인체(模型人體)를 치료대 위에 놓고 읽은 출력값과 모형인체(模型人體)없이 직접 읽은 출력값을 비교하여 Portal 영상을 위한 가능성을 제시하여 보았다.

  • PDF

사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름 (Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films)

  • 장지선;신동오;최병옥;이태규;최일봉;김문찬;권수일;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.47-53
    • /
    • 2006
  • 사이버나이프에 대한 정확한 선량측정은 정위방사선수술 전 과정에서 중요한 역할을 하고 있다. 본 연구에서는 여러 가지 검출기를 이용하여 사이버나이프의 상대적인 출력인자 값에 대하여 평가하고자 하였다. 사이버나이프는 12개 조준기를 사용하고 있으며, 이들 조준기에 대한 출력인자 값은 6개의 검출기(다이오드 검출기, X-Omat V 필름, Gafchromic EBT 필름, 0.015 cc, 0.125 cc, 0.6 cc 전리함)를 사용하여 측정하였다. 다이오드 검출기와 전리함은 물팬텀을 이용하여 선원과 표면 간의 거리 80 cm, 최대선량깊이인 1.5 cm에서 측정하였고 필름은 고체팬텀을 이용하여 물팬텀과 동일한 위치에서 측정하였다. 각 조준기의 출력인자는 사이버나이프의 최대 조사면의 크기인 직경 60 mm 조준기의 출력인자 값에 대하여 규격화하였다. 조준기의 크기가 30 mm 이상인 경우 0.6 cc 전리함을 제외하고 다른 검출기에서 0.5% 이내로 상호 잘 일치하였다. 그러나 15 mm 이하의 조준기에서는 출력인자 값이 검출기의 종류에 따라 다소 차이가 있음을 확인하였다. 즉, 다이오드 검출기와 Gafchromic 필름 경우 5 mm 조준기의 출력인자는 각각 $0.656{\pm}0.009$$0.777{\pm}0.013$이었다. 전리함과 다이오드 검출기에서 이러한 차이는 깊이에 따라 선량률 변화가 급격하고 측방쪽으로의 전자평형상태(lateral electronic equilibrium)가 이루어지지 않은 것으로 기인된다. 그러므로 Gafchromic EBT 필름이 사이버나이프 출력인자 값을 결정하는데 다른 검출기에 비하여 보다 정확하다고 사료된다.

  • PDF

고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구 (Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy)

  • 정해선;한영이;금오연;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.290-297
    • /
    • 2009
  • 고에너지 광자선 기반의 소조사면을 이용한 방사선 치료 시, 조사면의 가장자리에서의 급격한 선량 변화, 전자의 비평형상태, 검출기의 체적 효과 및 검출기와 팬텀 물질과의 불균질성 등으로 인하여 정확한 선량 측정이 어렵다. 따라서 본 연구에서는 선량 측정을 위해 널리 사용되는 전리함, 다이오드 검출기 및 물과 등가인 재질로 이루어져 측정 시 오차 유발 요인이 적은 것으로 알려진 $GAFCHROMIC^{(R)}$ EBT 필름을 이용하여 팬텀 내 소조사면에서의 흡수선량을 측정하고, 각 검출기들의 특성 및 EBT 필름의 유용성을 평가하였다. 각 검출기는 팬텀 표면으로부터 10 cm 깊이에 장착, 선원과의 거리(SAD)를 100 cm로 하였으며, 6 MV X-선 빔을 6개 조사면($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$$0.5{\times}0.5\;cm^2$)으로 팬텀에 조사하였다. $5{\times}5\;cm^2{\sim}1.5{\times}1.5\;cm^2$ 조사면의 경우, 모든 검출기들의 선량값이 1% 이내로 정확하게 일치하였으나, $1{\times}1\;cm^2$ 이하 조사면에서는 전리함을 이용한 측정결과가 타 검출기들에 비해 선량값을 매우 낮게 평가하는 것으로 확인되었다. 이는 검출기 체적효과가 매우 큰 오차요인으로 작용한 것으로 예측되어, 이를 제거하기 위해 제적 효과를 보정하는 컨볼루션 이론을 적용하여 측정된 선량값을 보정하였다. 그 결과, 다이오드 검출기의 경우 $1{\times}1\;cm^2$의 조사면에서는 EBT 필름의 흡수선량보다 약 3%가 높게, 전리함은 약 1% 낮게 측정되었다. $0.5{\times}0.5\;cm^2$ 조사면에서 다이오드 검출기는 약 1% 높은 값을, 전리함은 7% 낮은 선량값을 나타내었다. 결론적으로 $GAFCHROMIC^{(R)}$ EBT 필름의 소조사면 선량측정기로서의 유용성을 확인하였으며, 몬테카를로 전산모사를 이용한 추가 검증이 수행될 예정이다.

  • PDF

The Laser Range Finder for the Mobile Robot Navigation using a Lock-in Amplifier

  • Yoon, Hee-Sun;Shin, Myung-Kwan;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1423-1426
    • /
    • 2005
  • Map building is the most important thing for the mobile robots navigation. It requires specific vision system such as CCD camera, range finding system, and many other things. Laser range finder has highly collimated beams can be obtained easily, thus achieving lateral resolution. Laser Diode is used for a continuous laser source. The Automatic Current Control Circuit and the Bias-T is used for mix AC signal with DC bias. This signal is used for driving Laser Diode. The main idea of the calculating distance is detecting phase shift between reference signal and detected signal by photo detector. For the signal processing, the Lock-in amplifier system is addressed in this paper. We used a diffused reflected beam to detect phase shift in this system. But this beam is minuteness signal so it can be easily buried in nose. Lock-in amplifier is used to measure the amplitude and phase of signals which are buried in noise.

  • PDF

분광특성을 이용한 소형의 메탄 가스 감지 시스템 (Small Methane Detection System using Optical Spectrum Characteristics)

  • 조경화;류근준;김응수
    • 센서학회지
    • /
    • 제20권1호
    • /
    • pp.53-57
    • /
    • 2011
  • We developed a small methane detection system because methane gas is used in many areas and is dangerous. The developed system consisted of LD(Laser Diode) tuned a wavelength of $1.65\;{\mu}m$, two mirrors to collect a laser beam, photo detector. It could detect methane gas at a long range and its sensitivity was 1.98 V/$CH_4%$.

검파회로의 입력등가저항에 관한 연구 (Study on Equivalent Input Resistance of N-Phase Diode Detector.)

  • 김양모;이충웅
    • 대한전자공학회논문지
    • /
    • 제12권3호
    • /
    • pp.26-29
    • /
    • 1975
  • 본 논문은 먼저 n상다이오드평균검파전로와 n상다이오드 포낙선검파국락의 정기파 신호에 대한 입력등가저항을 검파각로의 부하단에서 발생하는 전력손실로 부터 해석적으로 구하였다. 또한 동일한 방법으로 임의의 주기적 신호에 대한 n상다이오드 포낙선검액회로의 입력권가저항도 구하였다.

  • PDF

아나로그 베이스밴드변조를 이용한 광섬유 영상신호 전송방식 (Optical-Fiber Video Trannamission System Using Analog Baseband modulation)

  • 정종래;박한규
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1983년도 추계학술발표회논문집
    • /
    • pp.32-34
    • /
    • 1983
  • In this paper, an analog optical filter link is evaluated for the transmission of baseband video signals over a single fiber. LED and PIN photo diode are used as the optical source and the detector. Frequency response of the system, DP, DG and SNR are measured.

  • PDF

최근의 CT의 동향

  • 조장희
    • 전자공학회지
    • /
    • 제8권1호
    • /
    • pp.16-32
    • /
    • 1981
  • 물리학적인 측면과 공학적인 측면에서의 CT(computerized tomography)의 최근 동향과 발전 과정을 되돌아 보고 의료 현장에서 실제 사용되고 있거나 아직 연구되고 있는 CTsystem의 성능과 그 특성에 대해 기술해 보았다. 또한 CT의 역사적인 발전과정, tomophysics 및 chemistry, system의 구성, detector 및 sensing diode, 신호의 수집과 처리를 위한 전자회로, computer system 및 주변 연산장치등에 대해서 고찰하였다.

  • PDF

Development of Spectroscopy Toolkit for Spectrum Measurement Experiments Using a CsI(Tl)/PIN Diode Detector

  • Nam, Young-Mi;Kim, Han-Soo;Ha, Jang-Ho;Lee, Jae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.77-80
    • /
    • 2010
  • The spectroscopy toolkit has been developed and tested. The toolkit consists of a CsI(Tl)/PIN diode detector, integrated electronics, and a multi.channel.analyzer and its size was 40 cm(width) by 20 cm(length) by 6 cm(high). It is compact, very portable and simpler and cheaper compared to the conventional spectroscopy system. The gamma energy resolutions of the toolkit were 7.9% for the 660 keV of $^{137}Cs$ and 4.9% for 1,332 keV of $^{60}Co$ respectively. The linearity for gamma energies was good. When the energy spectrum of a ceramic sample containing $^{232}Th$ was measured with the spectroscopy toolkit for 20 minutes, there were significant peaks of the heavy metal. These results show that the resolution of the spectroscopy toolkit is sufficient to accumulate a quality spectrum in a few minutes by using weak, encapsulated commercial sources. Furthermore a toolkit experiment that how to measure energy spectra using the toolkit, and how to identify specific isotopes in a pottery piece, could be widely adopted for education and even for more sophisticated and higher level experiments.