• Title/Summary/Keyword: Dimensional changes

Search Result 1,581, Processing Time 0.04 seconds

Dimensional Changes of Ceromer Crown by Water Absorption (치과용 심미수복재료 세로모에서 수분흡수와 체적 변화에 관한 연구)

  • Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.119-124
    • /
    • 2009
  • Statement of problem: The increasing demand for esthetic restorations has been required developing new materials for tooth colored restoration. Ceromer(Ceramic Optimized Polymer) has some advantages over porcelain, and has gained increasing popularity in restorative dentistry. However, there is little information on the dimensional changes in a clinical restoration in moist conditions. Purpose: This study examined the dimensional changes in Ceromer restorations with a clinical crown shape that were fabricated in a clinical manner. Material and methods: The crowns for the maxillary central incisor were fabricated with two Ceromers($BelleGlass^{(R)}$ and $Targis^{(R)}$) using a similar clinical restoration manufacturing technique. A total of twenty specimens were prepared and immersed in distilled water at room temperature to allow for water absorption. The weight, height and width were measured at 24, 72 and 168 hours. The accumulated ratios of the changes were calculated and evaluated using a paired t-test and an independent independent t-test. Results: The dimensions and weight increased with increasing soaking time. $Targis^{(R)}$ showed significant differences in height and weight between 24 hours and the other times(P<.05). $BelleGlass^{(R)}$ showed significant differences in width and weight between 24 hours and the other times. The two materials showed different changing patterns of the dimensions but there were no statistically significant differences between them. Conclusion: The dimensions and weight of the Ceromer restorations were changed by water absorption. The clinical crown shaped specimen showed more complicated dimensional changes than the simplified specimens.

Dimensional Error Analysis of Products from LOM Process (LOM 공정에서의 제품 치수 오차 분석에 관한 연구)

  • 하성도;김경환;송용억;박태권;김창희
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.89-96
    • /
    • 1998
  • LOM (Laminated Object Manufacturing) process is one of rapid prototyping processes, where shapes are formed by accumulating cross sections of laser-cut paper. The process expects wide popularity since it is simple and the material is familiar to conventional mockup makers. However the dimensional accuracy of LOM parts is not so good as that of traditional wooden mockups, since the stack of adhesive-spread papers causes significant dimensional error. Also it is unclear how the other unknown environmental effects cause the errors as well. In this work the dimensional errors of LOM parts are measured and analysed. Experiments with test parts were performed in order to see the effects of part shape, moist, and sealer on dimensional variations. The characteristic of the paper is also analysed. Re-heating LOM parts, which is shown to have the effect of recovering dimensional changes, is applied to an example part.

  • PDF

The factors of dimensional change of Fe-Cu-C sintered objects

  • Fujinaga, Masashi;Suzuki, Yoshitomo
    • Journal of Powder Materials
    • /
    • v.5 no.4
    • /
    • pp.299-302
    • /
    • 1998
  • Dimensional accuracy is one of the most important issues in the production of sintered parts. The iron-copper-carbon system is commonly used alloys in sintered structural parts production. The dimensional control of these alloys, however, is not easy because of their complex sintering behavior. This study is an effort to clarify the influence of common factors on dimensional change of Fe-Cu-C sintered structural parts. We determined the effect of such various parameters as chemical composition, particle diameter, compact density, sintering temperature and sintering time on dimensional changes. Consequently, we obtained a useful formula to predict the final dimension in function of these parameters. The effect of typical impurities in copper powder on the dimensional change of sintered parts has also been described.

  • PDF

Evaluation of Two-Dimensional Space of Human Sensibility Mutation by IAPS (IAPS 사진을 이용한 이차원 공간의 감성 변화 평가)

  • 민병찬;정순철;강인형;최지연;김철중
    • Science of Emotion and Sensibility
    • /
    • v.6 no.2
    • /
    • pp.21-28
    • /
    • 2003
  • Tn the present study, 9 photographs from the International Affective Picture System (IAPS) judged to express best 2-dimensional sensibility were selected and used to stimulate the subjects. The goal of the study lay in verifying whether or not the consequent affective changes in the subjects can be discriminated psychologically and physiologically in terms of arousal and relaxation. In order to determine affective changes, the physiological signals of the subjects' autonomic nervous system were measured through electrocardiogram (ECG) , galvanic skin response (GSR), skin temperature, and respiration. After stimulation and measurement, subjective evaluation was conducted. Subjective evaluation revealed that affective arousal level could be classified into 4 consecutive stages: arousal 〉 unpleasant arousal, pleasant arousal 〉 comfort 〉 relaxation. Analysis revealed that the responses of the autonomic nervous system, too, could be classified into 3 consecutive stages: arousal, unpleasant arousal, pleasant arousal 〉 comfort 〉 relaxation. By selecting and using 9 photographs from the IAPS deemed best to express Koreans'2-dimensional sensibility, the present study confirmed that it is possible to discriminate changes in the subjects' affective arousal level in terms of arousal and relaxation through psychological and physiological evaluation.

  • PDF

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut

  • Guleryuz, Aysegul;Korkmaz, Cumhur;Sener, Ayse;Tas, Mehmet Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.304-315
    • /
    • 2021
  • PURPOSE. Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue. MATERIALS AND METHODS. PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05). RESULTS. The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P* = .016, P* = .042, P < .001, respectively). CONCLUSION. Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.

2-Dimensional Model Development for Water Quality Prediction

  • Paik, Do-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.489-497
    • /
    • 2005
  • A numerical method for the mathematical water modeling in 2-dimensional flow has been developed. The model based on a split operator technique, in which, the advection term is calculated using the upwind scheme. The diffusion term is one- dimensionalized and calculated using Crank-Nicholson's implicit finite difference scheme to reduce the numerical errors from large time steps and variable spacings. It also provides a relatively simple and economic method for more accurate simulation of pollutant dispersion. Water depths and flow velocities in the Boreyong reservoir during the normal water periods were predicted by numerical experiments with a 2-dimensional flow model so as to provide current field data for the study of advection and diffusion of pollutants. Developed 2-dimensional water quality model is applied to Boreyong reservoir to simulate a spatial and periodical changes of water quality.

Study on performance of unit OLED device for 3-dimensional image-process (3차원 영상구현을 위한 OLED 단위소자 특성에 대한 연구)

  • Lee, Jeong-Ho;Kim, Jae-In;O, Yeong-Hae
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.07a
    • /
    • pp.204-205
    • /
    • 2005
  • Studies on display has been requested some major changes due to the high growth of the handheld terminal market. Therefore, the self emitting OLED(Organic Light Emitting Diode) has been interested as a next generation flat plane display because of its preeminent characteristics such as quick response characteristics, higher performance viewing angle, low power consumption, and panel floating. However, a trend of the display market is moving to three dimensional image processing instead of two dimensional flat display and various researches on display using hologram makes up for the difficulty in three dimensional display using typical flat display. In this study the Lenticular Screen Printing method is presented so that it can be applicable to organic semiconductor display devices and makes possible three dimensional display using flat display for complement the drawback of inorganic semiconductor.