• Title/Summary/Keyword: Dimension stability

검색결과 241건 처리시간 0.027초

프랙탈 차원과 표면적 지수를 이용한 지형인자와 사면안정성 비교 연구 (Study on the comparison topographical factor with slope stability using fractal dimension and surface area index)

  • 노수각;장병욱;차경섭
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.387-392
    • /
    • 2005
  • The research was performed to predict the potential landslide with roughness index. It was known that fractal dimension and surface area index can be represented the topography, specially when the natural slopes were rough or rugged. A test site was selected and fractal dimension and surface area index were calculated from the irregular triangle network. Fractal dimension were ranged between $2.016{\sim}2.046$ and surface area index $1.56E+07{\sim}2.59E+07$. Surface area index increased as fractal dimension increased. Slope stability was calculated by infinite slope stability analysis model and was compared to slope stability by fractal and surface area index. In the result, unsafe zones where slope stability is under 1.1 were $5.11{\sim}6.25%$ for the test site. It can be said that fractal dimension and surface area index are a good index to evaluate the slope stability because when fractal dimension and surface area index are greater, then stability of the site is more unsafe.

  • PDF

THE STABILITY OF CERTAIN SETS OF ATTACHED PRIME IDEALS RELATED TO COSEQUENCE IN DIMENSION > k

  • Khanh, Pham Huu
    • 대한수학회보
    • /
    • 제53권5호
    • /
    • pp.1385-1394
    • /
    • 2016
  • Let (R, m) be a Noetherian local ring, I, J two ideals of R, and A an Artinian R-module. Let $k{\geq}0$ be an integer and $r=Width_{>k}(I,A)$ the supremum of lengths of A-cosequences in dimension > k in I defined by Nhan-Hoang [9]. It is first shown that for each $t{\leq}r$ and each sequence $x_1,{\cdots},x_t$ which is an A-cosequence in dimension > k, the set $$\Large(\bigcup^{t}_{i=0}Att_R(0:_A(x_1^{n_1},{\ldots},x_i^{n_i})))_{{\geq}k}$$ is independent of the choice of $n_1,{\ldots},n_t$. Let r be the eventual value of $Width_{>k}(0:_AJ^n)$. Then our second result says that for each $t{\leq}r$ the set $\large(\bigcup\limits_{i=0}^{t}Att_R(Tor_i^R(R/I,\;(0:_AJ^n))))_{{\geq}k}$ is stable for large n.

PEG처리 수침고목재의 조습건조 (Humidity-Controlled Drying of PEG-Treated Waterlogged Woods)

  • 이광희;김수철;박원규
    • 보존과학회지
    • /
    • 제27권1호
    • /
    • pp.91-100
    • /
    • 2011
  • 본 연구에서는 열화된 소나무류를 대상으로 PEG 처리 후 조습건조시 적정 PEG농도, 습도 및 시간을 조사하고자 하였고, 조습건조과정 중 치수안정화 효과를 진공동결건조 및 자연건조한 것과 비교하였다. 조습건조에서 PEG의 농도가 높을수록 건조시간이 단축되었으며 치수안정성이 우수하였다. 저농도(40%, 50%) PEG 함침 후 조습건조는 치수안정화 효과가 적었고 목재표면 및 내부에 갈라짐이 발생하였으며 PEG의 분포가 불균일하였다. 고농도(60%, 70%) PEG 함침 후 조습건조를 하였을 때 목재의 표면은 흑화현상으로 인해 색은 어두워졌으나, 저농도(40%) PEG 함침 후 진공동결건조한 것과 비교하여 거의 동일한 치수안정화 효과를 나타내었다. 따라서 대형발굴수침고목재의 보존처리시 진공동결건조가 불가능할 경우 고농도 PEG(70%) 함침 후 조습건조하는 방법이 가능하고, 이때 건조습도와 건조시간을 충분히 고려해서 건조해야 함을 알 수 있었다.

A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient

  • Lee, Dae-Hyun;Ku, Young;Rhyu, In-Chul;Hong, Jeong-Ug;Lee, Cheol-Woo;Heo, Min-Suk;Huh, Kyung-Hoe
    • Journal of Periodontal and Implant Science
    • /
    • 제40권1호
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: It has been suggested that primary implant stability plays an essential role in successful osseointegration. Resonance frequency analysis (RFA) is widely used to measure the initial stability of implants because it provides superior reproducibility and non-invasiveness. The purpose of this study is to investigate whether the fractal dimension from the panoramic radiograph is related to the primary stability of the implant as represented by RFA. Methods: This study included 22 patients who underwent dental implant installation at the Department of Periodontology of Seoul National University Dental Hospital. Morphometric analysis and fractal analysis of the bone trabecular pattern were performed using panoramic radiographs, and the implant stability quotient (ISQ) values were measured after implant installation using RFA. The radiographs of 52 implant sites were analyzed, and the ISQ values were compared with the results from the morphometric analysis and fractal analysis. Results: The Pearson correlation showed a linear correlation between the ISQ values of RFA and the parameters of morphometric analysis but not of statistical significance. The fractal dimension had a linear correlation that was statistically significant. The correlation was more pronounced in the mandible. Conclusions: In conclusion, we suggest that the fractal dimension acquired from the panoramic radiograph may be a useful predictor of the initial stability of dental implants.

Non-periodic motions and fractals of a circular arch under follower forces with small disturbances

  • Fukuchi, Nobuyoshi;Tanaka, Takashi
    • Steel and Composite Structures
    • /
    • 제6권2호
    • /
    • pp.87-101
    • /
    • 2006
  • The deformation and dynamic behavior mechanism of submerged shell-like lattice structures with membranes are in principle of a non-conservative nature as circulatory system under hydrostatic pressure and disturbance forces of various types, existing in a marine environment. This paper deals with a characteristic analysis on quasi-periodic and chaotic behavior of a circular arch under follower forces with small disturbances. The stability region chart of the disturbed equilibrium in an excitation field was calculated numerically. Then, the periodic and chaotic behaviors of a circular arch were investigated by executing the time histories of motion, power spectrum, phase plane portraits and the Poincare section. According to the results of these studies, the state of a dynamic aspect scenario of a circular arch could be shifted from one of quasi-oscillatory motion to one of chaotic motion. Moreover, the correlation dimension of fractal dynamics was calculated corresponding to stochastic behaviors of a circular arch. This research indicates the possibility of making use of the correlation dimension as a stability index.

GORENSTEIN QUASI-RESOLVING SUBCATEGORIES

  • Cao, Weiqing;Wei, Jiaqun
    • 대한수학회지
    • /
    • 제59권4호
    • /
    • pp.733-756
    • /
    • 2022
  • In this paper, we introduce the notion of Gorenstein quasiresolving subcategories (denoted by 𝒢𝒬𝓡𝒳 (𝓐)) in term of quasi-resolving subcategory 𝒳. We define a resolution dimension relative to the Gorenstein quasi-resolving categories 𝒢𝒬𝓡𝒳 (𝓐). In addition, we study the stability of 𝒢𝒬𝓡𝒳 (𝓐) and apply the obtained properties to special subcategories and in particular to modules categories. Finally, we use the restricted flat dimension of right B-module M to characterize the finitistic dimension of the endomorphism algebra B of a 𝒢𝒬𝒳-projective A-module M.

라멜라-바이오 나노하이브리드: 3 Dimension-liposome을 이용한 카테킨(EGCG)에 안정화에 대한 연구 (Lamellar-bio nano-hybrid; The Study for Stability of Catechin (Green Tea: EGCG) Using 3-Dimensional Liposome)

  • Hong Geun, Ji;Jung Sik, Choi;Hee Suk, Kwon;Sung Rack, Cho;Byoung Kee, Jo
    • 대한화장품학회지
    • /
    • 제30권2호
    • /
    • pp.201-205
    • /
    • 2004
  • 최근 고기능성 화장품이 출시되면서 기능성 원료가 빛, 열, 산소에 매우 불안정하여 다양한 방법으로 안정성을 높이려고 연구되어 지고 있다. 특히, 카테킨은 주름 개선에 탁월한 원료이지만 빛, 열, 산소에 매우 불안정하다. 본 연구에서는 카테킨을 3Dimension화 하여 안정성 및 피부 침투를 높였다. 1 dimension으로 sol-gel method로 실리카를 다공성으로 만들어서 다공성 부문에 카테킨을 흡착시킨다. 2 dimension으로 다공성 실리카에 흡착디어진 카테킨을 non-phospholipid 베지클을 이용하여 solid lipid nanoparticle(SLN)을 만든다. 마지막으로 3dimension은 SLN되어진 카테킨을 skin lipid matrix를 이용하여 lameller phase self organization시킨다. 3 Dimension-카테킨은 일반적인 리포좀에 비해 빛과 열에 대한 color 안정성을 chromameter로 측정한 결과 5-10배 더 안정하였으며, HPLC 분석 결과 카테킨의 생존율이 3-5배 더 개선되었다. 또한 penetration effect를 측정한 결과 일반 리포좀보다 더 깊게 침투되었다. Wrinkle reduction effect를 한달 후에 측정한 결과 일반 리포좀보다 주름이 현저하게 감소되었다. 이러한 여러 가지 실험을 위해서 Laser light scattering system, cryo-SEM, chroma meter, HPLC, image analyzer, microfludizer 등을 사용하였다.

정서의 이차원 구조에서 유아의 얼굴표정 해석 (Children's Interpretation of Facial Expression onto Two-Dimension Structure of Emotion)

  • 신영숙;정현숙
    • 인지과학
    • /
    • 제18권1호
    • /
    • pp.57-68
    • /
    • 2007
  • 본 논문은 정서의 이차원 구조상에서 얼굴표정으로부터 아동의 정서이해에 대한 범주를 알아보고자 한다. 3세에서 5세 89명의 아동들을 대상으로 14개의 정서 단어와 관계된 얼굴표정들을 선택하도록 하였다. 실험에 적용된 얼굴표정들은 54명의 대학생들로부터 9점 척도상에서 두차원(쾌-불쾌차원과 각성-수면차원) 각각에서 표정의 강도가 평정된 사진들이 사용되었다. 실험결과에서 아동들은 쾌-불쾌 차원보다는 각성-수면 차원에서 더 큰 안정성을 보였다. 이차원 구조상에서 슬픔, 졸림, 화남, 놀람과 같은 정서들은 두 차원에서 매우 잘 변별된 반면, 두려움, 지겨움과 같은 정서들은 쾌-불쾌 차원에서 불안정성을 보였다. 특히 3세 아동들은 각성-수면정도에 대한 지각이 쾌-불쾌에 대한 지각보다 높게 나타났다.

  • PDF

의치상 레진의 중합 방법에 따른 크기의 안정성 및 표면 형태에 관한 연구 (DIMENSIONAL STABILITY AND SURFACE MORPHOLOGY OF VARIOUS DENTURE RESINS)

  • 채숙영;방몽숙
    • 대한치과보철학회지
    • /
    • 제30권3호
    • /
    • pp.401-410
    • /
    • 1992
  • The purpose of this study was to investigate the dimensional changes and surface morphology of dentures processed by various polymerization conditions. The measurements were done by taking radiograph and using vernier calipers and each specimen was observed on scanning electron microscope. Results obtained were as follows. 1. The difference of dimensional stability was not recognized between various polymerization conditions(heat-cured resin, pour-type resin, microwave-cured resin, and injection molding resin). 2. There were expansion and shrinkage in the occlusal dimension, shrinkage in the frontal dimension, and expansion in the lateral dimension. 3. Scanning electron microscope pictures of heat-cured resin showed dense and regular surface morphology. 4. Microwave-cured resin surface appeared more regular and smooth than pour-type resin but less dense and more irregular than heat-cured resin. 5. Scanning electron microscope pictures of pour-type resin with the lowest dimensional change showed the most irregular surface morphology.

  • PDF

방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구 (A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT)

  • 안형준;김창회;김영수;김용호
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF