• Title/Summary/Keyword: Dimension measurement

Search Result 504, Processing Time 0.024 seconds

A Study on the System of the Precision Dimensional Measurements for Molded Product Carbon Materials (탄소재 성형품에 대한 정밀 치수 검사 시스템에 관한 연구)

  • Kim, Dae-Nyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.37-42
    • /
    • 2016
  • This paper proposes a method to develop a high-precision dimension measurement system using a linear variable differential transformer sensor. The Dimension targets for measurement is carbon material vanes of key element in the rotating parts within vehicle circulating pump. Data acquisition system for dimension measurement is designed using the NI Compact RIO. And the program applying the dimension measurement algorithm is built using NI LabVIEW. The dimension measuring program is composed of a FPGA program, Real Time program and Host program. The method of the experiment compares master vane with target vane for measure the length of the carbon material vane. The experimental results confirmed the usefulness of the accuracy within ${\pm}4um$.

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 김도훈;유원재;박낙규;강영준
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

Measurement of Rock Slope Joint using 3D Image Processing (3차원 영상처리를 이용한 암반 사면의 절리 측정에 관한 연구)

  • Lee, Seung-Ho;Hwang, Jeong-Cheol;Sim, Seok-Rae;Jeong, Tae-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.854-861
    • /
    • 2005
  • Studied accuracy and practical use possibility of joint measurement that using 3D laser scanner to rock slope. Measured joint of Rock slope and comparison applied 3 dimension laser scanner and clinometer. 3D laser scanning system preserves on computer calculating to 3 dimension coordinate scaning laser to object. and according to laser measurement method of interior, produce correct vector value from charge-coupled device(CCD) or laser reciver and telegram register and time measuring equipment. Create of object x, y, z point coordinates to 3 dimension space of computer. Such 3 dimension point datum (Point Clouds) forms relocate position informations that exist to practical space to computer space. Practical numerical values related between each other. Compared joint distribution and direction that measured by laser scanner and clinometer. By the result, Distribution of joint projected almost equally. Could get more joint datas by measurement of 3 dimension scanner than measured by clinometer. Therefore, There is effect that objectification of rock slope investigation data, shortening of investigation periods, investigation reduction of cost. could know that it is very effective method in joint measuring.

  • PDF

Children's Strategies for Measurement Estimation of Rectangular Covering Tasks (직사각형 덮기 과제를 해결하면서 나타난 초등학생의 어림 측정 전략)

  • Lee, Jong-Euk
    • The Mathematical Education
    • /
    • v.49 no.3
    • /
    • pp.375-387
    • /
    • 2010
  • The focus of this article is the strategies young children use to solve rectangular covering tasks before they have been taught area measurement. seventy nine children from Grade 1 to 4 were observed while they solved various array-based tasks, and their drawing and explanation were collected and analyzed. Children's solution strategies were classified into incomplete covering, inadequate array, array constructed from moveable unit, measurement of one dimension, measurement of two dimension, and calculation. Implications for the learning of area measurement are addressed.

Measurement Of The Engine Oil Relative Dielectric Constant With Respect To Capacitive Prove Dimension (정전용량 프로브 크기에 대한 엔진오일 상대 유전율 측정)

  • Kim, Ki-Hoon;Kim, Young-Ju
    • Tribology and Lubricants
    • /
    • v.27 no.4
    • /
    • pp.209-212
    • /
    • 2011
  • The capacitive application(prove) can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents that we designed the analysis system of engine oil permittivity to know the relation between the engine oil deterioration and the prove dimension. Each of the dimension of capacitive prove is changed and then electric capacity is measured by LCR {Inductance(L), Capacitance (C), and Resistance (R)} meter. The engine oil permittivity has extracted in the prove measurement. As the additional research, this paper suggest the best of the prove dimension for the permittivity measurement.

Precise Edge Detection Method Using Sigmoid Function in Blurry and Noisy Image for TFT-LCD 2D Critical Dimension Measurement

  • Lee, Seung Woo;Lee, Sin Yong;Pahk, Heui Jae
    • Current Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.69-78
    • /
    • 2018
  • This paper presents a precise edge detection algorithm for the critical dimension (CD) measurement of a Thin-Film Transistor Liquid-Crystal Display (TFT-LCD) pattern. The sigmoid surface function is proposed to model the blurred step edge. This model can simultaneously find the position and geometry of the edge precisely. The nonlinear least squares fitting method (Levenberg-Marquardt method) is used to model the image intensity distribution into the proposed sigmoid blurred edge model. The suggested algorithm is verified by comparing the CD measurement repeatability from high-magnified blurry and noisy TFT-LCD images with those from the previous Laplacian of Gaussian (LoG) based sub-pixel edge detection algorithm and error function fitting method. The proposed fitting-based edge detection algorithm produces more precise results than the previous method. The suggested algorithm can be applied to in-line precision CD measurement for high-resolution display devices.

In-line Critical Dimension Measurement System Development of LCD Pattern Proposed by Newly Developed Edge Detection Algorithm

  • Park, Sung-Hoon;Lee, Jeong-Ho;Pahk, Heui-Jae
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.392-398
    • /
    • 2013
  • As the essential techniques for the CD (Critical Dimension) measurement of the LCD pattern, there are various modules such as an optics design, auto-focus [1-4], and precise edge detection. Since the operation of image enhancement to improve the CD measurement repeatability, a ring type of the reflected lighting optics is devised. It has a simpler structure than the transmission light optics, but it delivers the same output. The edge detection is the most essential function of the CD measurements. The CD measurement is a vital inspection for LCDs [5-6] and semiconductors [7-8] to improve the production yield rate, there are numbers of techniques to measure the CD. So in this study, a new subpixel algorithm is developed through facet modeling, which complements the previous sub-pixel edge detection algorithm. Currently this CD measurement system is being used in LCD manufacturing systems for repeatability of less than 30 nm.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

A Study on Sexual Differentiation by Means of Discriminant Functions in the Dental Easurement (치열계측의 판별함수에 의한 성별판정에 관한 연구)

  • 배재일;김한평
    • Journal of Oral Medicine and Pain
    • /
    • v.8 no.1
    • /
    • pp.121-126
    • /
    • 1983
  • This study is conducted with a view to make correct sexual differentiation by the utilization of discriminant functions. For that purpose were randomly sampled out 148 young adults testes, comprising 67 males and 81 females, ranging from 15 through 18 years fo age. Based on the values made available from the measurement of 6 items corresponding to the maxillary cast models, a statistical analysis was made to abstract feasible discriminant functions. The results findings are as follows: 1. The mean value by sex indicates, in all items, higher one in male group than in female group. 2. Through the measurement were defined as singnificant items in sexual differentiation the bucco-lingual dimensions of canine, 1st-molar, 2nd molar, and 1st bimolat width. 3. Derived from the value from measurement items were discriminant functions with the intention of applying them to sexual differentiation, as follows: 1) Y=-25.4112+0.7513BL3+0.3298BL4-0.2854BL5+0.7350BL6-0.3482BL7+0.2893AW (as tested by Method I) 2)Y=-25.0628+0.7737BL3+0.7468BL6-0.3885BL5+0.2951AW(as tested by Method II) BL3 : Bucco-lingual dimension of upper canine BL4 : Bucco-lingual dimension of upper first prmolar BL5 : Bucco-lingual dimension of upper second premolar BL5 : Bucco-lingual dimension of upper first molar BL6 : Bucco-lingual dimension of upper second molar AW : Upper first bimolar width 4. Sexual defferentiation in terms of descriminant functions represented a probility of 74.6%.

  • PDF