• 제목/요약/키워드: Digital relays

검색결과 68건 처리시간 0.029초

DC 옵셋의 영향을 제거한 페이저 연산 기법 (Phasor Estimation Method Eliminating the Effect of the DC offsets)

  • 이동규;김형규;권영진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.203_204
    • /
    • 2009
  • In this paper, we propose a Fourier transform-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Discrete Fourier Transform (DFT) is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. In this paper, the error due to DC offsets in a DFT is calculated and eliminated using the outputs of quaternity DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated by using computer-simulated signals and EMTP-generated signals. A performance evaluation showed that the proposed algorithm was not affected by system and fault conditions. Thus, the proposed algorithm can effectively suppress the adverse influence of DC offsets in a relaying signal.

  • PDF

변류기 포화 판단 알고리즘의 저역통과 필터에 대한 성능 분석 (Performance Analysis of a Lowpass Filter on a CT Saturation Detection Algorithm)

  • 강용철;옥승환;윤재성;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권10호
    • /
    • pp.495-501
    • /
    • 2002
  • A difference based current transformer (CT) saturation detection algorithm uses the third difference of a secondary current to detect the instants of the beginning/end of saturation. The third difference of a secondary current contains high frequency components when a CT is saturated. Thus, an effect of an anti-aliasing lowpass filter implemented in digital protection relays on the detection algorithm should be studied. This paper describes performance analysis of a lowpass filter on the CT saturation detection algorithm. The cutoff frequency of the lowpass filter is normally set to be half of a sampling frequency. In this Paper, two sampling frequencies of 3,840 (Hz) corresponding to 64 sample/cycle (s/c) and 1,920 (Hz) corresponding to 32 (s/c) are studied; the cutoff frequencies of the lowpass filters are set to be 1,920 (Hz), 960 (Hz) and 960(Hz), 480(Hz), respectively. And the proposed algorithm is verified by experiment. A 2nd order Butterworth filter is designed as a lowpass filter. The test results and experiment results clearly indicate that the saturation detection algorithm successfully detects the instants of the beginning/end of saturation even though a secondary current is filtered by the designed lowpass filters.

고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구 (A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated High Frequency Signals)

  • 이동준;김철환;김일동
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권8호
    • /
    • pp.924-931
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range. High frequency signals caused by sudden changes in system voltage that occurs in the immediate post-fault period are generally outside the bandwidth of receptibility of most protection scheme. In this respect, a specially designed stack tuner is connected to the coupling capacitor of CVT, in order to capture the high frequency signals. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the protected zone, and to discriminate the fault type. In this paper, modal transform is not applied to fault generated signals, because signals which are converted by modal transform are not have an information of each phase any longer. Instead, using peak voltage value of data windows is able to discriminate fault type. The paper concludes by presenting fault detection and discrimination of various faults on transmission line which are based on extensive simulation studies carried out on a typical 154kV Korean transmission line, using the EMTP software.

  • PDF

Design and Optimization for Distributed Compress-and-Forward System based on Multi-Relay Network

  • Bao, Junwei;Xu, Dazhuan;Luo, Hao;Zhang, Ruidan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.2949-2963
    • /
    • 2019
  • A novel distributed compress-and-forward (CF) system based on multi-relay network is presented. In this system, as the direct link between the source and destination is invalid due to some reasons, such as the limited power, special working environment, or even economic factors, relays are employed to receive analog signals and carry on distributed compressed encoding. Subsequently, the digital signals are transmitted to the destination via wireless channel. Moreover, a theoretical analysis for the system is provided by utilizing the Chief Executive Officer (CEO) theory and Shannon channel capacity theory, and the rate-distortion function as well as the connection between the transmission rate and the channel capacity are constructed. In addition, an optimal signal-to-noise ratio (SNR) -based power allocation method is proposed to maximize the quantization SNR under the limited total power. Simulation result shows that the proposed CF system outperforms the amplify-and-forward (AF) system versus the SNR performance.

초전도한류기 적용계통에서의 RTDS 보호계전기 연계시험을 위한 기본연구 (A basic study on protective relay testing using RTDS in power system applying SFCL)

  • 이승렬;윤재영;김재호;이병준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.35-39
    • /
    • 2009
  • The study for a protective relay system is one of the important technical issues on the power system application of Superconducting Fault Current Limiter (SFCL). We used Real Time Digital Simulator(RTDS) to study the true interaction of the protection system with the power system. RTDS modeling of SFCL is necessary to the detailed protective relay tests. In this paper, we developed an analysis model using RTDS for studying the transient behavior of 22.9kV SFCL and carried out closed-loop testing of protective relays in distribution power system with the developed SFCL model. The SFCL model has the operation mechanism of 22.9kV hybrid SFCL being developed by LSIS and KEPRI in Korea. The parameters of the model are based on the test data of the real SFCL. Power system planners and operators can solve the expected problems in power system application of SFCL using protective relay testing results.

초광대역 시스템의 계층변조 기반 적응적 듀얼 홉 전송 기법 (Adaptive Dual-Hop Transmission Based On Hierarchical Modulation in UWB System)

  • 김대환;송형규;조위덕
    • 한국통신학회논문지
    • /
    • 제36권7C호
    • /
    • pp.443-450
    • /
    • 2011
  • UWB(Ultra-Wideband)는 낮은 전력으로 초고속 통신을 실현하는 근거리 무선 통신 기술로서 주파수 부족 현상을 넘어서서 신규 기술을 도입할 수 있는 획기적인 기술 방식이다. UWB 전송방식 중의 하나인 MB-OFDM(Multiband Orthogonal Frequency Division Multiplexing) 시스템은 다양한 무선 통신 서비스에 적용이 가능하다. 본 논문에서는 협력 전송에서 전송률이 감소하는 문제를 해결하기 위한 UWB 시스템에서 계층 변조(HM : Hierarchical Modulation)와 순환 중복 검사를 통해 중계기에서 적응적으로 변조방식을 변경하는 새로운 중계 기법을 제시한다. 이는 기존 방법에 비해 비트 에러율은 비슷하며 처리량을 33%까지 증가시키는 장점이 있다.

LED 통신 기반 멀티 홉 오디오 데이터 전송네트워크시스템 (LED Communication based Multi-hop Audio Data Transmission Network System)

  • 조승완;리데덩;안병구
    • 전자공학회논문지
    • /
    • 제50권6호
    • /
    • pp.180-187
    • /
    • 2013
  • 본 논문에서는 LED 통신 기반 멀티 홉 오디오 데이터 전송네트워크 시스템을 제안개발 한다. 제안된 시스템의 주요한 기여도 및 특징은 다음과 같다. 첫째, 본 연구의 기여도는 LED 통신 기반으로 멀티 홉을 경유하여 오디오 데이터를 장거리 전송이 가능한 전송네트워크시스템을 개발하는 것이다. 둘째, 개발된 시스템의 특징은 전송부에서 오디오 데이터는 S/PDIF 포맷으로 인코딩 되어 보통의 LED로 통해 전송된다. 릴레이에서는 디지털 오디오 신호를 포토다이오드로 데이터를 수신 받아 에러체크 및 증폭을 하여 수신부로 전송한다. 수신부에서는 포토다이오드로부터 받은 인코딩된 오디오 데이터를 디코딩 및 증폭을 하여 아날로그 오디오 신호로 컨버팅을 한다. 제안된 시스템의 성능평가는 형광등이 켜져 있는 실험실에서 진행되었다. 성능평가 결과 제안된 시스템이 홉 간 거리가 긴 멀티 홉 네트워크 환경에서 고음질의 오디오 신호를 효과적으로 전송할 수 있었다. 반면에 사용된 다양한 LED들의 색깔에 따라서 오디오 데이터의 전송 음질에 차이가 있음을 확인 하였다.

VLC 기반 멀티 홉 멀티미디어 데이터 전송 네트워크 시스템 (Visible Light Communication based Multi-hop Multimedia Data Transmission Networks System)

  • 박인철;신정진;박주영;리데덩;안병구
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.21-31
    • /
    • 2014
  • 본 논문에서는 VLC를 이용한 멀티 홉 멀티미디어 데이터 전송 시스템을 제안개발 한다. 제안된 시스템의 주요한 기여도 및 특징은 다음과 같다. 첫째, 본 연구의 기여도는 LED 통신 기반으로 멀티 홉 기술을 사용하여 멀티미디어 데이터를 장거리 전송이 가능한 전송네트워크 시스템을 개발하는 것이다. 둘째, 개발된 시스템은 다음과 같은 주요한 특징이 있다. 전송부에서 오디오 데이터와 비디오 데이터를 두 개의 채널을 통하여 멀티 홉을 경유하여 전송된다. 오디오 채널의 릴레이에서는 전송된 신호를 포토다이오드로 데이터를 수신 받아 에러체크 및 증폭을 하여 수신부로 전송한다. 수신부에서는 포토다이오드로부터 받은 인코딩된 오디오 데이터를 디코딩 및 증폭을 하여 아날로그 오디오 신호로 컨버팅을 하여 스피커를 통해 오디오 데이터를 출력한다. 비디오 채널의 릴레이에서는 전송된 신호를 포토다이오드로 데이터를 수신 받아 OP-AMP로 신호를 증폭하여 LED를 통하여 수신부로 신호를 전송한다. 수신부에서는 포토 다이오드로부터 받은 비디오 데이터 신호를 OP-AMP로 증폭을 하여 모니터를 통해서 비디오 데이터를 출력한다. 제안된 시스템의 성능평가는 형광등이 켜져 있는 실험실에서 진행되었다. 성능평가 결과 제안된 시스템은 멀티미디어 데이터를 멀티 홉 네트워크를 경유하여 효과적으로 전송할 수 있음을 보여 주었다. 반면에 사용된 색깔에 따라서 전송된 멀티미디어 성능에 약간의 차이가 있음을 알 수 있었다.