• Title/Summary/Keyword: Digital power control

Search Result 1,380, Processing Time 0.027 seconds

A Study on Load Control in a Steam Turbine Power Plant using Acquired Data (운전데이터에 의한 증기터빈 발전소의 부하제어에 관한 고찰)

  • Woo, Joo-Hee;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.749-751
    • /
    • 1999
  • We acquired operating data in an existing steam turbine power plant using analog control system to investigate operation characteristics. We analyzed a load control logic to develop a digital turbine control system. The load control logic is constituted of load target, load reference, loading rate, load limit and admission mode transfer of valve. The result of this paper is utilized to implement a digital turbine control system.

  • PDF

Single-Phase Power Factor Correction(PFC) Converter Using the Variable gain (가변이득을 가지는 디지털제어 단상 역률보상회로)

  • Baek, J.W.;Shin, B.C.;Jeong, C.Y.;Lee, Y.W.;Yoo, D.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.240-243
    • /
    • 2001
  • This paper presents the digital controller using variable gain for single-phase power factor correction (PFC) converter. Generally, the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This is why input current is distorted under low input voltage. In particular, a digital controller has more time delay than an analog controller which degrades characteristics of control loop. So, it causes the problem that the gain of current control loop isn't increased enough. In addition, the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult. In this paper, the improved digital control method for single-phase power factor converter is presented. The variable gain according to input voltage and input current help to improve current shape. The 800W converter is manufactured to verify the proposed control method.

  • PDF

A DSP-Based Dual Loop Digital Controller Design and Implementation of a High Power Boost Converter for Hybrid Electric Vehicles Applications

  • Ellabban, Omar;Mierlo, Joeri Van;Lataire, Philippe
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.113-119
    • /
    • 2011
  • This paper presents a DSP based direct digital control design and implementation for a high power boost converter. A single loop and dual loop voltage control are digitally implemented and compared. The real time workshop (RTW) is used for automatic real-time code generation. Experimental results of a 20 kW boost converter based on the TMS320F2808 DSP during reference voltage changes, input voltage changes, and load disturbances are presented. The results show that the dual loop control achieves better steady state and transient performance than the single loop control. In addition, the experimental results validate the effectiveness of using the RTW for automatic code generation to speed up the system implementation.

DSP-Based Digital Controller for Multi-Phase Synchronous Buck Converters

  • Kim, Jung-Hoon;Lim, Jeong-Gyu;Chung, Se-Kyo;Song, Yu-Jin
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.410-417
    • /
    • 2009
  • This paper represents a design and implementation of a digital controller for a multi-phase synchronous buck converter (SBC) using a digital signal processor (DSP). The multi-phase SBC has generally been used for a voltage regulation module (VRM) of a microprocessor because of its high current handling capability at a low output voltage. The VRM requires high control performance of tight output regulation, high slew rate, and load sharing capability of multiple converters. In order to achieve these requirements, the design and implementation of a digital control system for a multi-phase SBC are presented in this paper. The digital PWM generation, current sensing, and voltage and current controller using a DSP TMS320F2812 are considered. The experimental results are provided to show the validity of the implemented digital control system.

Digital Control of Phase-Shifted Full-Bridge PWM Converter

  • Lim, Jeong-Gyu;Chung, Se-Kyo
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.201-209
    • /
    • 2008
  • This paper presents the modeling and design of a digital controller for a phase-shifted full-bridge converter (PSFBC) in a discrete-time domain. The discretized PSFBC model is first derived and then analyzed considering the sampling effect and the system parameters. Based on this model, the digital controller is directly designed in a discrete-time domain. The simulation and experimental results are provided to show the validity of the proposed modeling and controller design.

Analog to Digital Converter for CMOS Image Sensor (CMOS Image Sensor에 사용 가능한 아날로그/디지탈 변환)

  • 노주영;윤진한;장철상;손상희
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.137-140
    • /
    • 2002
  • This paper is proposed a 8-bit anolog to digital converter for CMOS image sensor. A anolog to digital converter for CMOS image sensor is required function to control gain. Proposed anolog to digital converter is used frequency divider to control gain. At 3.3 Volt power supply, total static power dissipation is 8mW and programmable gain control range is 30dB. The gain control range can be easily increased with insertion of additional flip-flop at divided-by-N frequency divider circuit.

  • PDF

Predictive Direct Torque Control Algorithm for Induction Motors and its Digital Implementation

  • Mutschler, Peter;Flach, Erich
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1-6
    • /
    • 1998
  • To achieve fast control action, direct control methods should be used. "Direct Mean Torque Control" (DMTC) combines the good dynamic performance of Direct Torque Control (DTC) with the advantages of inherently constant switching frequency and time equidistant control for implementation in a digital signal processor. Since DMTC is a predictive control algorithm, the model and its correction deserves special investigations. This paper proposes a steady-state Kalman filter which is well suited for fast computation.mputation.

  • PDF

Modified Digital Pulse Width Modulator for Power Converters with a Reduced Modulation Delay

  • Qahouq, Jaber Abu;Arikatla, Varaprasad;Arunachalam, Thanukamalam
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.98-103
    • /
    • 2012
  • This paper presents a digital pulse width modulator (DPWM) with a reduced digital modulation delay (a transport delay of the modulator) during the transient response of power converters. During the transient response operation of a power converter, as a result of dynamic variations such as load step-up or step-down, the closed loop controller will continuously adjust the duty cycle in order to regulate the output voltage. The larger the modulation delays, the larger the undesired output voltage deviation from the reference point. The three conventional DPWM techniques exhibit significant leading-edge and/or trailing-edge modulation delays. The DPWM technique proposed in this paper, which results in modulation delay reductions, is discussed, experimentally tested and compared with conventional modulation techniques.

New MPPT Control Strategy for Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • Bae, Hyun-Su;Park, Joung-Hu;Cho, Bo-Hyung;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.174-180
    • /
    • 2007
  • In this paper, a simple control method for two-stage utility grid-connected photovoltaic power conditioning systems (PCS) is proposed. This approach enables maximum power point (MPP) tracking control with post-stage inverter current information instead of calculating solar array power, which significantly simplifies the controller and the sensor. Furthermore, there is no feedback loop in the pre-stage converter to control the solar array voltage or current because the MPP tracker drives the converter switch duty cycle. This simple PCS control strategy can reduce the cost and size, and can be utilized with a low cost digital processor. For verification of the proposed control strategy, a 2.5kW two-stage photovoltaic grid-connected PCS hardware which consists of a boost converter cascaded with a single-phase inverter was built and tested.

Position and Pressure Control Using Hydraulic Axis Digital Controller (유압단축제어기(HACD)를 사용한 위치 및 압력제어)

  • Kim, D.H.;Huh, J.Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.29-35
    • /
    • 2011
  • These days the injection molding work and press work are in the trend of needing the precision control of position and pressure in a high speed. On the other hand the digital computer technology is developing rapidly. And recently the digital servo controller using micro controller become to be used more broadly, because of the merit of digital communication. In this study the sequential control of hydraulic system switching from position to pressure and to position is tried using the HACD(Hydraulic Axis Controller Digital for electrohydraulic drives) which is manufactured by BoschRexroth. Through this, the possibility of the precision sequential control using the digital servo controller HACD is examined.