• Title/Summary/Keyword: Digital fourier transform

Search Result 193, Processing Time 0.03 seconds

Target Altitude Extraction for Multibeam Surveillance Radar in Normal Environmental Condition (정상 환경 상태에서 다중 빔 탐색 레이다의 표적 고도 추출)

  • Chung, Myung-Soo;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.9
    • /
    • pp.1090-1097
    • /
    • 2007
  • The multibeam surveillance radar is a state-of art of 3D radar technology. It applies the stacked beam-on-received realized by a digital beamformer. In this paper, a design concept of beamformer and a method of target altitude extraction for multibeam surveillance radar in the normal environmental condition considering no multipath situations are proposed and investigated. The extraction algorithm based on antenna sine space coordinated system in a FFT digital beamformer is described. The proposed algorithm is simulated by 1 look-up table data and confirmed to have consistent results in accordance with a variety of target altitudes and a full radar frequency range.

Modified CSD Group Multiplier Design for Predetermined Coefficient Groups (그룹 곱셈 계수를 위한 Modified CSD 그룹 곱셈기 디자인)

  • Kim, Yong-Eun;Xu, Yi-Nan;Chung, Jin-Gyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.9
    • /
    • pp.48-53
    • /
    • 2007
  • Some digital signal processing applications, such as FFT, request multiplications with a group(or, groups) of a few predetermined coefficients. In this paper, based on the modified CSD algorithm, an efficient multiplier design method for predetermined coefficient groups is proposed. In the multiplier design for sine-cosine generator used in direct digital frequency synthesizer(DDFS), and in the multiplier design used in 128 point $radix-2^4$ FFT, it is shown that the area, power and delay time can be reduced up to 34%.

Secret-key-sharing Cryptosystem Using Optical Phase-shifting Digital Holography

  • Jeon, Seok Hee;Gil, Sang Keun
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.119-127
    • /
    • 2019
  • A new secret-key-sharing cryptosystem using optical phase-shifting digital holography is proposed. The proposed secret-key-sharing algorithm is based on the Diffie-Hellman key-exchange protocol, which is modified to an optical cipher system implemented by a two-step quadrature phase-shifting digital holographic encryption method using orthogonal polarization. Two unknown users' private keys are encrypted by two-step phase-shifting digital holography and are changed into three digital-hologram ciphers, which are stored by computer and are opened to a public communication network for secret-key-sharing. Two-step phase-shifting digital holograms are acquired by applying a phase step of 0 or ${\pi}/2$ in the reference beam's path. The encrypted digital hologram in the optical setup is a Fourier-transform hologram, and is recorded on CCDs with 256 quantized gray-level intensities. The digital hologram shows an analog-type noise-like randomized cipher with a two-dimensional array, which has a stronger security level than conventional electronic cryptography, due to the complexity of optical encryption, and protects against the possibility of a replay attack. Decryption with three encrypted digital holograms generates the same shared secret key for each user. Schematically, the proposed optical configuration has the advantage of producing a kind of double-key encryption, which can enhance security strength compared to the conventional Diffie-Hellman key-exchange protocol. Another advantage of the proposed secret-key-sharing cryptosystem is that it is free to change each user's private key in generating the public keys at any time. The proposed method is very effective cryptography when applied to a secret-key-exchange cryptosystem with high security strength.

Basic ]Requirements for Spectrum Analysis of Electroencephalographic Effects of Central Acting Drugs (중추성 작용 약물의 뇌파 효과의 정량화를 위한 스펙트럼 분석에 필요한 기본적 조건의 검토)

  • 임선희;권지숙;김기민;박상진;정성훈;이만기
    • Biomolecules & Therapeutics
    • /
    • v.8 no.1
    • /
    • pp.63-72
    • /
    • 2000
  • We intended to show some basic requirements for spectrum analysis of electroencephalogram (EEG) by visualizing the differences of the results according to different values of some parameters for analysis. Spectrum analysis is the most popular technique applied for the quantitative analysis of the electroen- cephalographic signals. Each step from signal acquisition through spectrum analysis to presentation of parameters was examined with providing some different values of parameters. The steps are:(1) signal acquisition; (2) spectrum analysis; (3) parameter extractions; and (4) presentation of results. In the step of signal acquisition, filtering and amplification of signal should be considered and sampling rate for analog-to-digital conversion is two-time faster than highest frequency component of signal. For the spectrum analysis, the length of signal or epoch size transformed to a function on frequency domain by courier transform is important. Win dowing method applied for the pre-processing before the analysis should be considered for reducing leakage problem. In the step of parameter extraction, data reduction has to be considered so that statistical comparison can be used in appropriate number of parameters. Generally, the log of power of all bands is derived from the spectrum. For good visualization and quantitative evaluation of time course of the parameters are presented in chronospectrogram.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

Measurement of natural frequency of aluminum honeycomb sandwich beams using high speed digital cameras (고속 디지털 카메라를 이용한 알루미늄 하니콤 샌드위치 보의 고유 진동수 계측)

  • Goo, Nam Seo;Vang, Hoang My;Le, Vinh Tung;Jin, Tailie
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • In this study, we measured the natural frequencies of aluminum honeycomb sandwich beams using digital image correlation technique. The vibration images were captured using two high speed digital cameras and the images were converted to displacements by the digital image correlation technique. Displacement data in time domain were tranformed to frequency domain data by fast Fourier transform software. To reduce noise invoked by random exitation, a spectrum averaging technique and Savitsky-Golay digital filter were adopted. A conventional vibration measurement using an accelerometer and a finite element analysis were performed to compare the results by high speed digital camera measurement method. In conclusion, new method using high speed digital cameras and digital image correlation technique can measure the vibration of beam structures and can be applied to bio-structures where sensors cannot be attached.

Resonant response of spar-type floating platform in coupled heave and pitch motion

  • Choi, E.Y.;Cho, J.R.;Jeong, W.B.
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.513-521
    • /
    • 2018
  • In this paper, the resonance response of spar-type floating platform in coupled heave and pitch motion is investigated using a CPU time-effective numerical method. A coupled nonlinear 2-DOF equation of motion is derived based on the potential wave theory and the rigid-body hydrodynamics. The transient responses are solved by the fourth-order Runge-Kutta (RK4) method and transformed to the frequency responses by the digital Fourier transform (DFT), and the first-order approximation of heave response is analytically derived. Through the numerical experiments, the theoretical derivation and the numerical formulation are verified from the comparison with the commercial software AQWA. And, the frequencies of resonance arising from the nonlinear coupling between heave and pitch motions are investigated and justified from the comparison with the analytically derived first-order approximation of heave response.

High-Performance Low-Power FFT Cores

  • Han, Wei;Erdogan, Ahmet T.;Arslan, Tughrul;Hasan, Mohd.
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.451-460
    • /
    • 2008
  • Recently, the power consumption of integrated circuits has been attracting increasing attention. Many techniques have been studied to improve the power efficiency of digital signal processing units such as fast Fourier transform (FFT) processors, which are popularly employed in both traditional research fields, such as satellite communications, and thriving consumer electronics, such as wireless communications. This paper presents solutions based on parallel architectures for high throughput and power efficient FFT cores. Different combinations of hybrid low-power techniques are exploited to reduce power consumption, such as multiplierless units which replace the complex multipliers in FFTs, low-power commutators based on an advanced interconnection, and parallel-pipelined architectures. A number of FFT cores are implemented and evaluated for their power/area performance. The results show that up to 38% and 55% power savings can be achieved by the proposed pipelined FFTs and parallel-pipelined FFTs respectively, compared to the conventional pipelined FFT processor architectures.

  • PDF

Implementation of an Over-Current Relaying Algorithm with TMS320C32 (TMS320C32를 이용한 한시 과전류 계전기의 구현)

  • Yoo, Sung-Rok;Yoon, Byung-Wook;Park, Byung-Woo;Choi, Chang-Yung;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2193_2194
    • /
    • 2009
  • A digital over current relay(OCR) is realized by using TMS320C32 microprocessor. Fourier Transform is used to obtain the phasor of a current signal and a 2nd low pass filter is adopted to prevent aliasing error. H/W test shows almost same results with those of the S/W test. It could be possible that confirm simularity between H/W and S/W test in this paper.

  • PDF

Development of a smart wireless sensing unit using off-the-shelf FPGA hardware and programming products

  • Kapoor, Chetan;Graves-Abe, Troy L.;Pei, Jin-Song
    • Smart Structures and Systems
    • /
    • v.3 no.1
    • /
    • pp.69-88
    • /
    • 2007
  • In this study, Field-Programmable Gate Arrays (FPGAs) are investigated as a practical solution to the challenge of designing an optimal platform for implementing algorithms in a wireless sensing unit for structuralhealth monitoring. Inherent advantages, such as tremendous processing power, coupled with reconfigurable and flexible architecture render FPGAs a prime candidate for the processing core in an optimal wireless sensor unit, especially when handling Digital Signal Processing (DSP) and system identification algorithms. This paper presents an effort to create a proof-of-concept unit, wherein an off-the-shelf FPGA development board, available at a price comparable to a microprocessor development board, was adopted. Data processing functions, including windowing, Fast Fourier Transform (FFT), and peak detection, were implemented in the FPGA using a Matlab Simulink-based high-level abstraction tool rather than hardware descriptive language. Simulations and laboratory tests were carried out to validate the design.