• Title/Summary/Keyword: Digital device

Search Result 2,228, Processing Time 0.028 seconds

Virtual Folder Based Approach to Digital Contents Control (가상폴더 접근방식의 디지털콘텐츠 관리방안)

  • Yoon, Han Seong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • EDMS systems have been a main alternative for enterprise content management (ECM), which provide valuable functions for the effective control and management of organization-level digital contents. However, it has not been effective frequently for the purpose of integrative control of overall contents in an organization. One of reasons for this problem is that individuals usually create and store files with their own personal computers and do not move them to the central storage and control device, EDMS. Many occasions show that this situation can cause undesirable results for better management of enterprise contents. This paper introduced an approach of virtual folder which can directly connect individual computers and EDMS storage device without users' inconvenience. Adding the capacity of restricting usage of individual computer, users unavoidably and conveniently store and retrieve digital contents using EDMS server system. Several modules and implementing architecture for the virtual folder system are shown and the results of utilizing the system are explained with a case of application.

Technical comparison between superconductive RSFQ logic circuits and silicon CMOS digital logics (초전도 디지털 RSFQ 논리회로와 실리콘 CMOS 회로와의 기술적 비교)

  • Cho, W.;Moon, G.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.26-28
    • /
    • 2006
  • The development technique of digital logic using CMOS device is close reached several limitations These make technical needs that are ultra high speed superconductive systems based on CMOS silicon digital computing technique. Comparing digital logic based on silicon CMOS, the computing technique based on ultra high speed superconductive systems has many advantages which are ultra low power consumption, ultra high operation speed. etc. It is estimated that features like these increasingly improve the possibility of ultra low power and ultra superconductive systems. In this paper digital logics of current CMOS technique and RSFQ superconductive technique are compared with and analyzed.

The Differential Effect of PC vs. Mobile on User Behavior : An Empirical Study based on Construal Level Theory(CLT) (데스크톱과 모바일 기기의 차이가 사용자의 행위에 미치는 영향 : 해석수준 이론을 적용한 실증 연구)

  • Suh, Kil-Soo;Kang, Hyunjeong
    • Journal of Information Technology Services
    • /
    • v.18 no.5
    • /
    • pp.31-51
    • /
    • 2019
  • Construal level theory (CLT) have been researched in wide range of disciplines such as marketing, organizational study, psychology, or education. Current study asserts that CLT would explain the effect of different devices of PC and smartphone on interaction between human-computer interfaces and information systems use. In CLT, those who are far from an object in terms of physical, temporal, social or psychological distance, they construe their understanding as abstract (high level) and vice versa. We hypothesized different size of digital device will increase psychological distance and result in behaviors that correspond to present construal level. The analysis result shows that users of PC recognized that they are socially distant from the device and those of smartphone felt that they are socially close to the device. However, the device did not have significant effect on attention to essential information, advertisement preference, and immediacy. The implication to academia, practice and future research and limitations are also discussed.

The Development and Evaluation of Cylinderical ROM-Media (원통형 롬-미디어의 개발과 평가)

  • Sung, Kap-Je;Cha, Sung-Woon
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.445-450
    • /
    • 2001
  • DVD(Digital Versatile Disk) is the data storage media devised to make high storage density and high data input/output possible. Therefore higher rotational speed and better accuracy in optical pick-up are required compared with the existing optical storage device. These operational functional requirements are concerned with abilities of optical storage device. Especially, High rotational speed is deeply concerned with the noise and vibration of optical storage device, is important problem in development of optical storage device so much. This paper propose a new concept ROM media of optical storage device named as Cylindrical ROM media, and evaluate this by means of Axiomatic approach and empirical data.

  • PDF

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

Augmenting Interactivity of Touch Pad by Adding Isometric Rate Control

  • Heo, Seong-Kook;Hahn, Min-Soo
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.240-244
    • /
    • 2009
  • In this paper, we present FloatingPad, a touch pad based device with better scrolling feature and more interaction styles than a traditional touch pad. When we interact with a real object like a picture or a book, we manipulate on the object, and we also move, rotate, and flip the object. We applied this idea into a touch pad. In FloatingPad, the touch pad is not fixed to the device. It is floating on the device; it can be slid on the device. Therefore a user can have additional degree of freedom of input by shifting and rotating the touch pad while having the traditional touch pad input. By using this technique, the interactivity of the touch pad can be augmented, and better scrolling feature can be provided by reducing clutching occurs on the position scrolling devices by using the movement of the touch pad as rate control. We implemented the prototype device and conducted a user study with three applications developed for FloatingPad.

  • PDF

A Prospective Study of Game Content based on Wearable Device (웨어러블 디바이스 기반의 게임콘텐츠 전망 연구)

  • Baek, Jaeyong;Chang, Hyojin;Kim, Youngjae
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.1
    • /
    • pp.145-155
    • /
    • 2015
  • The game industry has changed along with the advancement of device technology. The wearable, a recently appeared device will create new demand in this saturated age of the smart devices. The game industry's content targeted towards the wearable devices will play an important role as main driving source. For this reason, this research studies the development aspect and the current technical capabilities of games' platforms and contents by analyzing the contrast between the results of features and current situations of the wearable market. Consequently, we define the prospects of game content for wearable device. We also expect that the new style of the game content, combined with cloud game, augmented reality game and virtual reality game will appear in the next generation platforms gearing towards the wearable devices.

Study of Discharge Erasing Method of a-Se based Digital X-ray Detector (a-Se을 이용한 디지털 X-선 검출기의 Discharge Erasing Method에 관한 연구)

  • Lee, Dong-Gil;Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.395-398
    • /
    • 2002
  • Many research group started study to develope x-ray detector using thin film transistor from 1970. But realization of TFT based x-ray detector development was caused by progress of thin film transistor liquid crystal display(TFTLCD) device technology in 1990. The main current of TFT technology is display device. Research results expend TFT technology field from display device to sensor manufacture technology. These days many research group in the world realize various digital x-ray detector. In this study, We compare discharge erasing method to visible light erasing method in a-Se based digital x-ray detector. Visible light erasing method is known reset process in direct conversion x-ray detector. Digital x-ray detector using visible light erasing method is not adaptive for conventional x-ray device, because of its thickness. And it is not avaliable for real-time imaging for digital fluoroscopy, because of its long reset time. In this study we overcome these limitations and show new idea for real-time imaging method.

  • PDF

A Design and Implementation for a Reliable Data Storage in a Digital Tachograph (디지털 자동차운행기록계에서 안정적인 데이터 저장을 위한 설계 및 구현)

  • Baek, Sung Hoon;Son, Myunghee
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.2
    • /
    • pp.71-78
    • /
    • 2012
  • The digital tachograph is a device that automatically records speed and distance of a vehicle, together with the driver's activity and vehicle status at an accident. It records vehicle speed, break status, acceleration, engine RPM, longitude and latitude of GPS, accumulated distance, and so on. European Commission regulation made digital tachographs mandatory for all trucks from 2005. Republic of Korea made digital tachographs mandatory for all new business vehicles from 2011 and is widening the range of vehicles that must install digital tachographs year by year. This device is used to analyze driver's daily driving information and car accidents. Under a car accident that makes the device reliability unpredictable, it is very important to store driving information with maximum reliability for its original mission. We designed and implemented a practical digital tachograph. This paper presents a storage scheme that consists of a first storage device with small capacity at a high reliability and a second storage device with large capacity at a low cost in order to reliably records data with a hardware at a low cost. The first storage device records data in a SLC NAND flash memory in a log-structured style. We present a reverse partial scan that overcomes the slow scan time of log-structured storages at the boot stage. The scheme reduced the scan time of the first storage device by 1/50. In addition, our design includes a scheme that fast stores data at a moment of accident by 1/20 of data transfer time of a normal method.

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.