• 제목/요약/키워드: Digital dental model

검색결과 153건 처리시간 0.022초

치위생학과 학생의 디지털 리터러시와 전공만족과의 관련성 (Relationship between digital literacy level and major satisfaction in dental hygiene students)

  • 이민아;장종화
    • 한국치위생학회지
    • /
    • 제24권4호
    • /
    • pp.321-331
    • /
    • 2024
  • Objectives: This study aimed to investigate the digital literacy and major satisfaction levels of dental hygiene students and identify the interrelationships between them as well as the factors related to major satisfaction. Methods: An online survey was using a structured questionnaire was conducted with 223 dental hygiene students. Digital literacy and major satisfaction were measured using a 5-point Likert scale, and correlation and multiple regression analyses were performed. Results: The participants' digital literacy averaged 3.87 points, and their major satisfaction averaged 3.82 points. The digital literacy factor related to major satisfaction was critical thinking skills (β=0.747, p<0.001). This indicates that the higher the critical thinking skills, the higher the major satisfaction. The explanatory power of the model was 63.7%. Conclusions: Critical thinking skills as a factor of digital literacy were found to influence dental hygiene students' major satisfaction, suggesting that a curriculum that can increase critical thinking can improve major satisfaction.

치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가 (Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models)

  • 이경탁;김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권3호
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.

스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교 (Comparison of the accuracy of digital models made from white light scanner by scanning method)

  • 김기백;이경탁;김재홍
    • 한국치위생학회지
    • /
    • 제12권6호
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

총의치 제작을 위한 무치악 디지털 모형의 정확도 평가 (Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication)

  • 김원수;김기백
    • 치위생과학회지
    • /
    • 제15권4호
    • /
    • pp.393-398
    • /
    • 2015
  • 성공적인 보철치료를 위해서 가장 필요한 선행조건 중 하나는 환자의 구강과 정확한 모형의 제작이다. 최근 치과용 캐드캠을 이용한 보철물의 제작 수요가 증가함에 따라 본 연구에서는 총의치 제작을 위한 디지털 모형의 정확도를 평가함으로써 해당 임상가(치과의사, 치과위생사, 치과기공사)들에게 참고자료를 제시하고자 하였다. 이를 위해 기존 아날로그 제작 방식에 의한 석고 모형(대조군)과 이를 스캔하여 제작한 디지털 모형(실험군)을 각각 20개씩 제작 후 정확도 평가를 위한 6개의 계측지점을 선정하였다. 두 집단의 모형에서 측정된 6개의 계측지점의 평균을 비교 평가하는 방식으로 디지털 모형의 정확도를 평가하였다. 본 연구 결과 치과용 스캐너를 이용하여 제작된 디지털 모형이 아날로그 모형보다 작게 제작된다는 것을 알 수 있었으나 이는 통계적으로 유의하지 않았다. 또한 두 집단의 모형들에서 측정된 계측거리의 평균의 차이는 계측거리 별로 0.05~0.45 mm로 조사되었는데, 이러한 차이는 기존 선행 연구들에 근거하였을 때 그 정도가 미비한 것으로써 최종 보철물의 성패에는 영향을 미치지 않는 것을 알 수 있었다. 최근 치과용 캐드캠을 이용한 보철물의 제작 수요는 증가하고 있는데 반해 디지털 모형의 정확도와 관련한 연구는 매우 부족한 것을 감안하였을 때 본 연구는 관련 실험을 통해 결과를 도출하여 해당 임상가(치과의사, 치과위생사, 치과기공사)들에게 참고자료를 제시하고자 하였다는 점에서 의의가 있다고 생각된다. 본 연구 결과들을 종합하고, 선행 연구들의 결과에 비추어 보았을 때 치과용 캐드캠을 이용한 총의치 제작 시 제작되는 디지털 모형은 임상적으로 허용이 가능할 것으로 기대된다.

A Proposal for a Predictive Model for the Number of Patients with Periodontitis Exposed to Particulate Matter and Atmospheric Factors Using Deep Learning

  • Septika Prismasari;Kyuseok Kim;Hye Young Mun;Jung Yun Kang
    • 치위생과학회지
    • /
    • 제24권1호
    • /
    • pp.22-28
    • /
    • 2024
  • Background: Particulate matter (PM) has been extensively observed due to its negative association with human health. Previous research revealed the possible negative effect of air pollutant exposure on oral health. However, the predictive model between air pollutant exposure and the prevalence of periodontitis has not been observed yet. Therefore, this study aims to propose a predictive model for the number of patients with periodontitis exposed to PM and atmospheric factors in South Korea using deep learning. Methods: This study is a retrospective cohort study utilizing secondary data from the Korean Statistical Information Service and the Health Insurance Review and Assessment database for air pollution and the number of patients with periodontitis, respectively. Data from 2015 to 2022 were collected and consolidated every month, organized by region. Following data matching and management, the deep neural networks (DNN) model was applied, and the mean absolute percentage error (MAPE) value was calculated to ensure the accuracy of the model. Results: As we evaluated the DNN model with MAPE, the multivariate model of air pollution including exposure to PM2.5, PM10, and other atmospheric factors predict approximately 85% of the number of patients with periodontitis. The MAPE value ranged from 12.85 to 17.10 (mean±standard deviation=14.12±1.30), indicating a commendable level of accuracy. Conclusion: In this study, the predictive model for the number of patients with periodontitis is developed based on air pollution, including exposure to PM2.5, PM10, and other atmospheric factors. Additionally, various relevant factors are incorporated into the developed predictive model to elucidate specific causal relationships. It is anticipated that future research will lead to the development of a more accurate model for predicting the number of patients with periodontitis.

치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석 (Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system)

  • 김원수;한만소;정재관;김기백
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model

  • Kim, So-Yeun;Lee, So-Hyoun;Cho, Seong-Keun;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2014
  • PURPOSE. The accuracy of a gypsum model (GM), which was taken using a conventional silicone impression technique, was compared with that of a polyurethane model (PM), which was taken using an iTero$^{TM}$ digital impression system. MATERIALS AND METHODS. The maxillary first molar artificial tooth was selected as the reference tooth. The GMs were fabricated through a silicone impression of a reference tooth, and PMs were fabricated by a digital impression (n=9, in each group). The reference tooth and experimental models were scanned using a 3 shape convince$^{TM}$ scan system. Each GM and PM image was superimposed on the registered reference model (RM) and 2D images were obtained. The discrepancies of the points registered on the superimposed images were measured and defined as GM-RM group and PM-RM group. Statistical analysis was performed using a Student's T-test (${\alpha}=0.05$). RESULTS. A comparison of the absolute value of the discrepancy revealed a significant difference between the two groups only at the occlusal surface. The GM group showed a smaller mean discrepancy than the PM group. Significant differences in the GM-RM group and PM-RM group were observed in the margins (point a and f), mesial mid-axial wall (point b) and occlusal surfaces (point c and d). CONCLUSION. Under the conditions examined, the digitally fabricated polyurethane model showed a tendency for a reduced size in the margin than the reference tooth. The conventional gypsum model showed a smaller discrepancy on the occlusal surface than the polyurethane model.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.