• 제목/요약/키워드: Digital Vessel

검색결과 146건 처리시간 0.026초

A Study on Dynamic Safety Navigation Envelopes Considering a Ship's Position Uncertainty

  • Pyo-Woong Son;Youngki Kim;Tae Hyun Fang;Kiyeol Seo
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.289-294
    • /
    • 2023
  • As technologies such as cameras, Laser Imaging, Detection, and Ranging (LiDAR), and Global Navigation Satellite Systems (GNSS) become more sophisticated and common, their use in autonomous driving technologies is being explored in various fields. In the maritime area, technologies related to collision avoidance between ships are being developed to evaluate and avoid the risk of collision between ships by setting various scenarios. However, the position of each vessel used in the process of developing collision avoidance technology between vessels uses data obtained through GNSS, and may include a position error of 10 m or more depending on the situation. In this paper, a study on the dynamic safety navigation range including the positional inaccuracy of the ship is conducted. By combining the concept of the protection level obtained using GNSS raw data with a conventional safe navigation range, a safer navigation range can be calculated for dynamic navigation. The calculated range is verified using data obtained while sailing in an actual sea environment.

폐암 자동진단 시스템에 관한 기본적 연구 (A Study on Computer Assisted Diagnosis System(CAD) of Lung Cancer)

  • 문주영
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.465-468
    • /
    • 1997
  • A Study on Computer Assisted Diagnosis (CAD) system extract ing lung cancer part from Digital X-ray Computerized Tomography(CT) image is discussed in this paper. It is very crucial to segment the image of lung into the three organ area such as inside, outside and the hilum so that the variant image processing algorithm can be applied an each area respectively. In this paper, the efficient algorithm extracting lung cancer part is proposed with characterizing lung hilum part and its associated vessel patterns.

  • PDF

A Digital Bathymetric Model combining Multi Beam Echo Sounder and Sidescan Sonar

  • Park, Jo-Seph;Kim, Hik-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.330-330
    • /
    • 2002
  • The combination of Multi-Beam Echo Sounder swath bathymetry and high-resolution towed Sidescan sonar provides a powerful method of examination about hydrographic survey results. In this paper, we investigate the fast method of 3D bathymetric reconstruction with the Digital Sidescan sonar(Benthos SIS 1500) and Shallow Multi-Beam Echo Sounder(Reson Seabat 8125). The Seabat 8125 is a 455KHz high resolution focused Multibeam echo sounder(MBES) system which measures the relative water depth across a wide swath perpendicular to a vessel's track. The Benthos SIS1500 is a chirp(nominal fq. 200KHz) sonar which map the topographical features & sediment texture of ocean bottom using backscattered amplitude. We generates the very large 3D bathymetric texture mapping model with the Helical System's HHViewer and describes additional benefits of combining MBES and Sidescan Sonar imagery, the removal of geometric distortions in the model and a deterministic sounding noise.

  • PDF

뇌혈관 자기공명영상에서 Time-of-flight(TOF) 기법을 이용한 영상의 질 평가: 1.5 T 와 3.0 T 자기공명영상 비교 (The Evaluation of Image Quality using Time of Flight in Intracranial Magnetic Resonance Imaging : Comparison with 1.5 T and 3.0 T)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.43-48
    • /
    • 2015
  • Intracrnial 3D TOF MR angiography was performed in 30 normal volunteers with both 1.5 and 3.0 T MRI system with high resolutions. Used Voxel sizes were $0.39{\times}0.39{\times}0.2$(1.5 T) and $0.19{\times}0.19{\times}0.35$(3.0 T), respectively. High image quality and depiction of small vessel branches were equality demonstrated with 1.5 T and 3.0 T HR TOF MRA(p<0.05). Intracranial high resolution TOF MRA with 1.5 T and 3.0 T provides high diagnostic information with having merits and demerits in depiction of vascular branches.

  • PDF

뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 - (A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique-)

  • 최성현;구은회;황선광;이강원;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.7-12
    • /
    • 2012
  • The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(I) (A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(I))

  • 강영준;박낙규;유원재;김경석
    • 비파괴검사학회지
    • /
    • 제22권4호
    • /
    • pp.393-401
    • /
    • 2002
  • 원자력 발전소나 화학공장 등에서 사용되는 보편적인 부재중 하나인 압력배관은 사용중에 내부에 부식 등의 원인으로 결함이 발생되어 구조적 강도나 안전에 문제를 야기한다. 따라서, 이런 결함의 검출은 중요한 문제이다. 현재 신뢰성이 인정되어 사용되는 기존의 비파괴검사법으로는 초음파 X선 그리고 와전류에 의한 방법 등이 있다. 그렇지만 이러한 방법들은 검사하고자 하는 대상과 거의 접촉에 가까운 형태로 검사가 진행되고 있으며, 결함은 넓은 영역에 걸쳐 한번에 검출되지 못하고 탐촉자나 필름이 위치하는 부분으로 검사영역이 한정되는 단점이 있다. 그래서 검사에 많은 시간과 경비가 소모되고 있다. 본 연구에서는 이러한 단점들을 극복할 수 있는 레이저를 이용한 전자 전단 간섭법으로 결함을 측정하였다. 그리하여 압력용기의 내부에 존재하는 다양한 결함의 유무와 결함의 방향을 변위구배를 나타내는 간섭무늬로 검출하고, 검출된 결함에 위상 이동법을 적용하여 정량적으로 측정할 수 있었다. 본 연구는 두 편으로 구성된다. 그 첫 번째는 전자 전단 간섭법을 이용한 압력용기의 내부결함 검출에 관한 연구이고, 두 번째는 그 측정시스템의 오차분석에 관한 연구로 구성되어 있다.

PC를 기반으로 한 선박용 디지털 심전도 및 청진기 개발 (Development of Ship′s Digital ECG and Stethoscope Based on PC)

  • 이근실;문성배
    • 한국항해항만학회지
    • /
    • 제28권3호
    • /
    • pp.239-245
    • /
    • 2004
  • 심전도 측정기와 청진기를 통하여 획득된 심전도와 심음도는 비관혈적 방법으로 환자를 진단할 수 있는 생체신호이며, 의사들의 진단도구로 널리 이용되어져 왔다. 그러나 의사들이 심전도 측정기나 청진기를 이용하여 환자를 진단하는 장소는 병원 내 진료실과 응급실로 한정되어 있기 때문에, 병원에서 거리가 먼 원거리 지역이나 자동차, 비행기, 선박에서는 환자의 심음을 확인할 수 없다. 특히, 원양항해에 종사하는 선박 환자는 전문 의료진으로부터 진료를 받을 수 없는 경우가 있다. 본 논문에서는 환자의 심음 및 심전을 용이하게 측정함으로써 PC기반의 선박용 디지털 심전도 및 청진기를 개발하였으며, 해상 원격진료의 출현을 앞 당길 수 있으리라 본다.

흉부 CT 영상에서 개선된 폐 및 폐혈관 분할과 괴사 세포 비율의 수치적 알고리즘 (Improved Lung and Pulmonary Vessels Segmentation and Numerical Algorithms of Necrosis Cell Ratio in Lung CT Image)

  • 조준호;문성룡
    • 디지털융복합연구
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 2018
  • 흉부 CT 영상에서 폐 질환의 진단을 위해서 폐 분할, 폐혈관 분할과 폐 질환 부위에 대한 괴사 세포 비율의 수치적 계산을 제안 하였다. 첫 번째 단계는 흉부 CT 영상에서 3차원 레이블링 기법과 3차원 영역 성장법을 적용하여 폐와 기관지를 분리한다. 두 번째 단계는 폐혈관 분할은 1차 다항식 회귀(Polynomial Regression)를 사용한 변화율을 적용하여 분할한 다음, 잡음 제거를 실시하여 최종의 폐혈관을 분할한다. 세 번째 단계는 2단계 이미지 에서 질환 예상 인자를 발견하고, 괴사 세포의 비율을 계산하는 것이다. 질환 예상인자는 폐에 대해서 3차원 레이블링 기법을 적용하였고, 각 레이블 중심 값을 관측하여 변화가 없는 레이블을 찾는다. 이렇게 찾은 질환 예상 인자는 조영제 투입 전/후 영상을 정합한 뒤, 면적을 비교하면 폐의 괴사 세포 비율을 계산할 수 있다.

New Seed Detection by Shape Analysis for Construction of Vascular Structures

  • Shim, Hack-Joon;Lee, Hyun-Joon;Yun, Il-Dong;Lee, Sang-Uk
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권6호
    • /
    • pp.427-433
    • /
    • 2010
  • Although tracking methods are efficient and popular for vessel segmentation, they require a seed to initiate an instance of tracking. In this paper, a new method to detect new seeds for tracking of arterial segments from CT angiography (CTA) and to construct a vascular structure is proposed. The proposed algorithm is based on shape analysis of connected components in a volume of interest around a vessel segment which was already extracted by tracking. The eigenvalues of the covariance matrix are used as the shape features for detection. The experimental results on actual clinical data showed that the results totally revealed the arterial tree not hindered by bone or veins. In visual comparison to a method which combines registration and subtraction of both pre-contrast and post-contrast CT volumes, the proposed method produced comparable results to the reference method and were confirmed of its feasibility for clinical use of reducing the cost and burden of patients.