• 제목/요약/키워드: Digital Treatment

검색결과 1,090건 처리시간 0.031초

Effects of Exercise and Neuromuscular Electrical Stimulation on Lower Trapezius Muscle Activity in Individuals with Round Shoulder Posture

  • Jeong Pyo Seo;Heun-Jae Ryu
    • The Journal of Korean Physical Therapy
    • /
    • 제36권2호
    • /
    • pp.71-77
    • /
    • 2024
  • Purpose: The prolonged use of digital devices has led to the widespread adoption of poor postures, particularly rounded shoulder posture (RSP), associated with shoulder impingement and pain. This study investigates the effects of neuromuscular electrical stimulation (NMES) on RSP in healthy adults. Methods: Thirty adults with RSP were randomly assigned to NMES only, exercise only, or NMES with exercise groups. NMES was applied to the lower trapezius, which was the target muscle in this study, for a total of 2 weeks, 5 times per week, 20 minutes per session. The exercise program included pectoralis minor stretching, wall-slide exercise, dynamic hug exercise with band, and Brugger stretching for upper body with band, which were performed for a total of 2 weeks, 5 times per week, 20 minutes per session. Outcome measures, including the Supine Method (SM) for posture and surface electromyography (EMG) of the lower trapezius for muscle activity, were assessed before the intervention, after 5 sessions, and after 10 sessions. Results: All the groups showed significant changes in the SM and % maximal voluntary isometric contraction (%MVIC) over time (p<0.05). The NMES group had significantly reduced SM at 1 week, while the exercise and combined groups had reduced SM at 2 weeks (p<0.017). All the groups had increased %MVIC at 2 weeks (p<0.017), with no significant differences observed between groups. Conclusion: NMES alone can be as effective as exercise in improving RSP. NMES combined with exercise also showed positive outcomes, thus offering diverse treatment options for this condition.

양측성 순구개열 신생아 환자의 수술전 비치조 정형장치 치료에 의한 치조골 조형(molding) 효과의 분석 (Analysis of alveolar molding effects in infants with bilateral cleft lip and palate when treated with pre-surgical naso-alveolar molding appliance)

  • 남동석;양원식;백승학;김석화
    • 대한치과교정학회지
    • /
    • 제29권6호
    • /
    • pp.649-661
    • /
    • 1999
  • 본 연구의 목적은 1) 양측성 순구개열 신생아에 대한 수술전 비치조정형 장치 (Pre-surgical nasoalveolar molding appliance, PNAM) 치료를 소개하고, 2) 이 장치의 치조골 조형 (molding) 효과를 평가하는 것이다. 서울대학교병원 교정과에 내원하여 PNAM 장치를 사용하여 치료받은 8명의 양측성 순구개열 환자 (남자 7명, 여자 1명, 평균 초진 연령:61.6일)를 연구대상으로 하였으며, 치조골에서 전상악골의 치조능 좌우측 말단부와 양측 분절 치조능 최전방점까지의 파열부간 평균거리는 $8.09{\pm}5.03mm$였고 치조골 정형치료의 평균 기간은 $8.8{\pm}3.1$주였다. 초진시 (T0)와 성공적인 치조골 정형술이 완료된 시기(T1)에 인상을 채득하여 모형을 제작한 후, 사진 촬영과 digital caliper를 사용하여 20개의 길이항목과 14개의 각도항목을 계측하였다. Microsoft사의 Excel 97 program을 사용하여 각 항목의 계측치들을 통계 처리하였고, 치조골 정형술에 의한 치료전후의 차이를 비교하기 위하여 paired t-test를 사용하였다. PNAM 장치에 의한 치조골 조형 효과에 대한 결론은 다음과 같다. 1. 양측성 순구개열 파열부의 폐쇄가 성공적으로 이루어졌다. 2. 양측 분절의 측방 성장이 억제되어 내측 굴곡이 발생하였다. 3. 전상악골 후방부에 위치한 서골(vomer) 전방부의 굴곡에 의하여 전상악골의 후방이동과 회전이 발생하였다. 구순성형술을 시행하기 전에 PNAM장치를 사용하여 양측성 순구개열 신생아 환자의 파열부 폐쇄에 대한 좋은 결과를 얻을 수 있었다.

  • PDF

뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가 (Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image)

  • 이충운;유연욱;김용근;원우재
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.23-27
    • /
    • 2018
  • [목적] 뼈 검사는 골격계 질환에 대한 예민도와 높은 해상력의 핵의학 영상 검사이다. 본 연구는 추가적인 방사선피폭없이 뼈 검사 영상과 골반 X선 영상의 결합을 시행하고 영상의 해부학적 정보와 관용도를 증가시켜 환자 병변 진단에 도움이 되고자 한다. 2015년 11월에서 2016년 8월까지 본원에서 뼈 검사를 실시한 환자 중 골반 X선 촬영을 시행한 236명을 대상으로 진행하였다.(남자 64명, 여자 172명, 평균연령 $50.96{\pm}15.39$세) 검사장비는 감마카메라 Symbia Ecam(SIEMENS, Germany)을 사용하였고 디지털 엑스레이는 DRS-800(Listem, Korea)을 사용하였다. 영상의 결합 및 분석프로그램은 Osirix version 3.8.1(Osirix, USA), 통계프로그램은 Stata/SE 버전 14.0(StataCorp, USA)를 사용하였다. 환자에게 $^{99m}Tc-DPD$ 740 MBq을 정맥주사한 후 2~4시간이 지난 뒤에 검사를 진행하였다. 감마카메라 영상 획득 조건은 Matrix size $256{\times}1024$, Zoom 1.00, 검사 속도 17 cm/min로 하였다. 디지털 엑스레이는 Collimator size $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp(60~97kVp), 평균 30 mAs(20~48)로 전상장골극과 치골결합 사이 수직입사를 하였다. Osirix 상에서 골반 뼈의 윤곽 및 가상의점을 선택하여 결합하고 획득한 영상을 핵의학과 5년 이상 근무한 방사선사 3명에 의해 평가 되었으며, 모두 동일할 경우 일치, 하나라도 동일하지 않을 경우 불일치로 평가하였다. 전체 236명 중 일치하는 대상은 216명 (91.53%) 이다. 연령의 중위수 및 범위(최소값~최대값)는 일치하지 않는 그룹에서 67(46~81)세, 일치하는 그룹에서 52(22~87)세로, 일치하지 않는 그룹의 연령이 더 높은 것을 확인하였고, 두 군 간에 연령이 다른지 Wilcoxon rank-sum test를 수행해 본 결과, 통계적으로 유의하게 두 군 간에 나이가 차이나는 것을 확인할 수 있었다(p < 0.0001). 남자는 64명 중 60명(93.75%), 여자는 172명 중 156명(90.70%)가 일치하였고, 골반 병변이 없던 환자는 54명 중 54명(100.00%), 골반 병변이 있던 환자는 182명 중 162명(89.01%) 일치하였고, 골반 병변 여부에 따른 일치율은 통계적으로 유의한 차이를 보였다(p = 0.0094). 뼈 검사와 골반 X선 영상을 결합하는데 있어서 여러 가지 변수가 있을 수 있었고 환자의 연령과 골반병변이 영상의 결합에 일부 영향을 줄 수 있을 것으로 생각된다. 본 연구를 통하여 방사선 피폭 없이 소아의 골반 골육종 진단에 도움이 되리라 사료되고 이와 같은 영상의 결합 연구를 통해서 핵의학 영상발전에 도움이 될 것으로 기대된다.

수아세포종의 수술 후 외부 방사선치료 (Postoperative External Beam Radiotherapy for Medulloblastoma)

  • 전하정;이명자
    • Radiation Oncology Journal
    • /
    • 제18권2호
    • /
    • pp.101-106
    • /
    • 2000
  • 목적 : 수아세포종에 대한 수술 후 두개척수 방사선종양학 의학용어집에 따라 방사선치료의 효과를 평가하고 최적의 방사선치료 방법을 알아보고자 함이 본 연구의 목적이다. 대상 및 방법 : 1984년 5월부터 1998년 4월까지 본원 치료방사선과에서 두개척수 외부 방사선치료를 받은 43명의 수아세포종 환자를 후향적으로 분석하였다. 추적기간은 18개월에서 U개월이었으며 중앙추적기간은 47개월이었다. 남자는 27명이었고 여자는 16명으로서 남자와 여자의 비율은 1.7: 1이었다. 5명의 환자에서는 조직검사만을 시행하였고 14명에서는 육안적 완전절제술, 나머지 24명의 환자에서는 아절제술을 시행하였다. 모든 환자는 두개척수 방사선치료를 받았고, 39명의 환자는 최소 5,000 cGy의 방사선을 원발부위에 조사받았으며 40명의 환자는 최소 3,000cGy의 방사선을 척수에 조사받았다. 결과 : 대상환자 43명의 5년 및 7년 생존율은 67$\%$ 및 56$\%$이었고, 5년 및 7년 무병생존율은 각각 60$\%$ 및 51$\%$이었다. 원발병소의 국소제어율은 5년 및 7년에 각각 77$\%$ 및 67$\%$이었다. 육안적 완전절제술 및 아절제술을 시행받은 환자의 5년 생존율은 각각 76$\%$ 및 66$\%$이었으며 반면에 조직검사만을 시행받은 환자는 5년 생존율이 40$\%$에 불과 하였다. 총 18명의 재발환자 중 11명에서 원발부위가 재발부위이었으며 7명의 환자는 원발병소에서만 재발하였다. 4명의 환자는 척수에서, 3명의 환자는 원격전이만을 보였고 나머지 4명의 환자에서는 원발부위를 포함하여 여러부위에서 재발하는 양상을 나타내었다. 결론 : 수아세포종의 뇌척추 방사선치료는 유의한 치료 부작용이 없는 효과적인 치료요법이었다. 그러나 원발부위의 국소치료효과를 높이기 위하여 개선하여야 할 점이 있는 것으로 사료되며 이는 다분할조사, 정위적 방사선수술 및 삼차원 입체 조형치료 등 방사선요법의 기술적 발전으로 이루어 질 수 있을 것으로 생각된다.

  • PDF

合谷($LI_4$), 三間($LI_3$)의 電針刺戟이 顔面部 領域 溫度變化에 미치는 影響 (Effects on the Thermal Change of the Face Follow Electroacupunctyre on Hapkok($LI_4$), Sangan($LI_3$))

  • 윤정훈;김종한;황충연;임규상
    • 한방안이비인후피부과학회지
    • /
    • 제12권2호
    • /
    • pp.222-247
    • /
    • 1999
  • The back ground and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it has been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. As electroacupuncture is one of acupuncture treatments, it will show more objective index to observe the meridian and qi xue(氣血) phenomenon. And then, I studied the effects on the thermal change of the face following electroacupuncture treatment. Objective and Methods : This study was performed from January 1999 to March 1999 on 10 healthy students. The objective was divided into three groups, those were the control group A(n=10), the group B(n=10) of electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and the group C(n=10) of electroacupuncture on Shinmun($H_7$), T' ongni($H_5$). First, in the control group A, we took a picture for 10 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.I.) and did 3min after, 10min after, 15min after, 25min after, 45min after respectively. Second, in the electroacupuncture treatment group B, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and took a picture immediately(3min after), 10min after, 15min after and remove needle and took a picture in the same way respectively. Third, in the electroacupuncture treatment group C, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Shinmun($H_7$), T'ongni($H_5$) and took a picture in the second way respectively. Results: 1. In healthy men, average skin temperture about Yonghyang($LI_{20}$) area was higher than Soryo($G_{25}$) or Chich'ang($S_4$) area. They were Soryo($G_{25}$) area $31.495{\pm}0.766^{\circ}C$, Rt. Yonghyang($LI_{20}$) area $31.664{\pm}0.936^{\circ}C$, Lt. Yonghyang ($LI_{20}$)area $31.686{\pm}0.767^{\circ}C$, Rt. Chich'ang($S_4$) area $31.226{\pm}0.875^{\circ}$, Lt. Chich'ang ($S_4$) area $31.453{\pm}0.855^{\circ}C$. 2. In the control group A, the skin temperature of Soryo($G_{25}$) showed the increase or decrease in below ${\Delta}0.1^{\circ}C\;except\;0.265{\pm}0.594^{\circ}C$ in 25min, but not significantly. 3. About Soryo($G_{25}$) area, the skin temperature decreased significantly after electroacupuncture immediately. ${\Delta}T $of the group B was $-0.970{\pm}0.87\;1^{\circ}C$, which was larger than one of the group C which was $-0.707{\pm}0.624^{\circ}C$ at 3min. And then ${\Delta}T$ of the group C was increase valuable at 25min, 45min. 4. About Yonghyang($L1_{25}$) area, the left ${\Delta}T$ of the group B showed below $0.2^{\circ}C$ or so in contrast to the right it. In the group C, on the both side showed continous increase of temperature as following times. 5. About Chich'ang($S_4$) area, the skin temperature increased valuable $0.3^{\circ}C$ or so on the both side and later inclined to decrease in the group B but not significantly. In the group C, it increased valuable on the both side. 6. The skin temperature of electroacupuncture treatment group B, C were more increase than the control group A except Lt. Yonghyang($LI_{20}$) area in the group B. The temperature of group C were more increase than the group B wholly. Conclusion : The above results indicate that D.I.T.I. is a useful method to observe and fallow-up the effects and the changes by electroacupuncture stimulation on objective evaluation of phenomenon for the meridian system and character. Thus, continuous thermographic study will be needed for more clinical application such as acupuncture and medicine or laser therapy according to oriental medicine.

  • PDF

2D 및 3D 디지털 이미지 분석과 함께 Moir$\acute{e}$ Tophography 분석을 이용한 화장품의 가슴 탄력개선 효과 평가 (Assessment of the Breast-Firmming Effects of a Cosmetic Preparation with Moir$\acute{e}$ Tophography in Combination with 2D and 3D Digital Image Analyses)

  • 서영경;유미애;류자현;김소정;조성아;남개원;조준철;부용출;고재숙
    • 대한화장품학회지
    • /
    • 제38권4호
    • /
    • pp.289-296
    • /
    • 2012
  • 외과적으로 가슴의 볼륨 측정은 석고법, 가슴 X선 사진을 이용한 가슴의 볼륨을 산출하는 방법과 MRI, 3차원 측정 시스템 등을 이용한 측정 방법들이 주로 이용되었다. 그러나 최근 화장품 영역에서 가슴 볼륨 증가 및 탄력개선 제품의 증가로 효능평가가 필요하나 외과적 방법들의 적용은 어려운 실정이다. 그리하여 본 연구는 화장품 영역에서 최초로 등고선 사진을 이용하여 가슴 탄력개선을 평가하였다. 또한 가슴둘레 측정, 디지털 이미지 분석, 3차원 가슴이미지 분석 값과의 상관성을 비교하였고 등고선 사진평가를 가슴의 탄력을 평가하는 새로운 방법으로 제안하고자 하였다. 본 연구는 병력조사 및 피부 상태 진단을 통해 건강한 여성 피험자 30명이 시험에 참여하였다. 피험자로 하여금 제품사용 전과 2주, 4주, 8주 후 시점에서 가슴둘레 측정, 유두점의 각도와 거리 분석, Moire's Topography를 이용한 scoring, 3D가슴측정을 실시하여 가슴확대 및 탄력개선 정도를 평가하였다. 평가 결과 디지털 이미지를 분석결과 유두점의 각도(Angle)는 시점별로 증가하는 경향을 보였으나 유의성은 없었다. 유두점으로부터 밑가슴까지의 길이(Length)는 시점별로 유의하게 증가하였다(p < 0.05). 또한, 유두점으로부터 밑가슴까지의 높이는 4주 후, 8주 후 시점에서 통계적으로 유의하게 증가하였다(p < 0.05). Moire's Topography Score 평가 결과 각 시점별로 유의하게 개선하였다(p < 0.05). 3차원 가슴 부피 분석 값은 각 시점별로 증가하는 경향을 보였으나 통계적 유의성은 없었다. 상관성 분석결과 Moir$\acute{e}$ tophography score는 디지털 이미지 분석 값 중 길이, 높이와 유의한 상관성이 있었고 3차원 부피 분석 값과 유의한 상관성이 관찰되었다. 따라서 Moire's Topography Score 평가는 이미지 분석과 3차원 부피분석 평가법과 더불어 화장품에 의한 탄력 및 처짐 개선을 평가하는 데 중요한 평가방법으로 사용될 것으로 사료된다.

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • 섬유기술과 산업
    • /
    • 제2권4호
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

On board imager를 이용한 치료간 환자 셋업오차 평가 (Evaluation of the Interfraction Setup Errors using On Board- Imager (OBI))

  • 장은성;백성민;고성진;강세식
    • 한국방사선학회논문지
    • /
    • 제3권3호
    • /
    • pp.5-11
    • /
    • 2009
  • 영상유도방사선치료(image guided radiation therapy: IGRT) 시 환자를 1차적으로 skin marker를 이용하여 위치시키고 2차적으로 OBI(on board imager)를 이용하여 해부학적 위치를 확인 후 couch를 움직여 set up을 보정하게 되는데, 이때 발생하는 오차에 대한 평가를 하려고 한다. 치료계획시 $0^{\circ}$$270^{\circ}$방향의 DRR(digital reconstructed radiography) 영상과 OBI로 촬영한 영상을 2차원-2차원 정합(2D-2D matching)으로 비교하여 치료계획시 환자의 셋업과 치료시 환자의 셋업의 오차를 비교하였다. Head&Neck 및 Spinal cord와 같은 주요장기 부위의 치료에서는 치료때 마다 OBI에 의하여 셋업시 확인하였으며, Chest 및 Abdomen&Pelvic 는 일주일에 2~3회 확인하였다. 그려나 보정 값은 모두 OIS(oncology information system)에 기록하여 160명의 환자를 대상으로 각각 Head&Neck, Chest 및 Abdomen&Pelvic으로 나누어 피부 지표를 이용한 셋업의 정확성을 평가하였다. Head&Neck 환자의 평균 셋업 오차는 각각 AP, SI, RL 방향에서 $0.2{\pm}0.2cm$, $-0.1{\pm}0.1cm$, $-0.2{\pm}0.0cm$ 로 나타났으며, Chest의 경우 $-0.5{\pm}0.1cm$, $0.3{\pm}0.3cm$, $0.4{\pm}0.2cm$ 로 나타났고 Abdomen의 경우 $0.4{\pm}0.4cm$, $-0.5{\pm}0.1cm$, $-0.4{\pm}0.1cm$로 나타났다. Pelvic 의 경우 $0.5{\pm}0.3cm$, $0.8{\pm}0.4cm$, $-0.3{\pm}0.2cm$ 나타났다. Head&Neck 같은 강체 (rigid body)는 셋업 오차가 Chest 및 Abdomen 부위에 비하여 상대적으로 작게 나타났다. Chest에서는 횡축 방향의 오차가 컸으며, Abdomen&Pelvic 에서는 AP 방향의 오차가 크게 나타났다. Chest에서 횡축오차가 크게 나타난 이유는 환자 셋업시 환자 몸의 휘어짐에 기인한 것이며, Abdomen에서의 AP방향의 오차가 큰 이유는 환자의 호흡으로 인해 앞뒤 위치의 변화 때문으로 사료된다. 환자 셋업 시스템에서는 systematic error는 나타나지 않았다. OBI는 해부학적 위치를 확인하기 때문에 병소가 피부에 위치해 있을 경우 피부마커로 셋업을 하는 것이 정확할 것으로 생각된다. 2차원-2차원 정합은 3차원-3차원 정합과 비교하여 rolling 오차를 찾아내지 못하나 환자의 피폭이 적다는 장점이 있으며 셋업 확인 시간이 짧기 때문에 실제 임상에서는 2차원-2차원 정합이 유용하였다.

  • PDF

국내거주 외국인을 위한 한국형 치과정보 이해능력 평가도구의 개발 (Development of test for Korean functional health literacy in dentistry)

  • 김현경;노희진;정임희;정원균;이윤;문소정;전현선;한선영;최은희;기준성;구민지;정주희
    • 한국치위생학회지
    • /
    • 제16권3호
    • /
    • pp.355-362
    • /
    • 2016
  • Objectives: This study aimed to develop a tool for assessing foreigners' understanding of oral health information in Korea called the Test of Korean Functional Health Literacy in Dentistry(TOKFHLiD) and examined validity and reliability of the tool. The TOKFHLiD consists of two literacy assessment parts: Dental Information Sentence(DIS) aims to assess one's literacy of sentences containing oral health information. Dental Information Document(DID) aims to assess one's numeracy and literacy of documents containing oral health information. Methods: Twenty eight preliminary questions were developed based on various medical care literature such as the agreement to diagnosis and treatment and the treatment precautions. DID using 14 preliminary questions was developed based on the appointment card, the treatment schedule, and labels on oral care products. The 42 preliminary questions in the DIS and the DID were subsequently put through four separate expert reviews, in which questions with content validity score of less than 0.8(13/15 points) were corrected and modified by five dental experts and then were corrected for language errors by two Korean language experts. The preliminary assessment tool was tested on 153 Koreans, and ${\chi}^2$ test was performed on the ratio of respondents who comprehended each question, the ratio of respondents who chose the correct answer for each question with a significance level of 0.05. Results: Of the 42 preliminary questions, 1 question in DIS and 1 question in DID, for which the ratio of Korean respondents who chose the correct answers did not exceed the acceptable level of 80%, were excluded and a final assessment tool was completed with 40 questions. Conclusions: Following the development and application of the tool, examination of the TOKHLiD for validity and reliability revealed that this assessment tool is adequate for assessing oral health information literacy of foreigners who are using oral hygiene medical services in Korea.

전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진 (PTV Margins for Prostate Treatments with an Endorectal Balloon)

  • 김희정;정진범;하성환;김재성;예성준
    • Radiation Oncology Journal
    • /
    • 제28권3호
    • /
    • pp.166-176
    • /
    • 2010
  • 목 적: 직장 내 풍선삽입을 하는 전립선 암 환자의 3차원 입체조형방사선치료(3D CRT)와 세기조절치료에 대한 적절한 계획표적부피 마진을 구하기 위하여 본 연구를 수행하였다. 대상 및 방법: 환자는 반듯이 누운 자세에서 치료계획용 CT 촬영과 매 치료 전에 환자의 직장에 풍선이 삽입되었고 70 mL의 공기로 풍선을 팽창시켰다. Anterior-posterior (AP)와 측면에서의 전자식 조사문영상 이미지와 디지털 화재구성사진을 이용하여 치료간 환자 치료위치 및 풍선의 위치 변화를 분석하였다. 두 이미지를 정합하기 위하여 Visual $C^{++}$ 기반의 프로그램을 개발하여 사용하였다. 기존의 방법을 기반으로 풍선에 의한 선량 흐려짐 효과를 고려한 계획표적부피 마진을 구하는 방법 고안하였다. 결 과: 환자치료위치의 치료간 변화는 모든 방향에서 평균 1 mm 이내로 나타났다. 풍선의 치료간 변화는 left-right (LR) 방향에 비해 superior-inferior (SI)와 AP 방향으로 크게 나타났다. 풍선의 무작위오차를 포함시켜 새로 고안된 1차원 계획표적부피 마진 구하는 방법을 사용하여 마진을 구한 결과, 3D CRT의 경우에는 LR 방향으로 3.0 mm, SI 방향으로 8.2 mm, AP 방향으로 8.5 mm로 계산되었다. Intensity modulated radiation therapy의 경우, LR 방향으로 4.1 mm, SI 방향으로 7.9 mm, AP 방향으로 10.3 mm로 마진이 계산되었다. 결 론: 풍선의 무작위오차는 전립선 모양의 변형을 일으켜서 선량분포에 영향을 준다. 따라서, 새로 고안된 계획표적부피 마진을 구하는 방법에는 풍선에 의한 선량 흐려짐 효과가 고려되었다. 이 방법은 풍선의 무작위오차만 계산에 포함하기 때문에 풍선의 계통오차에 대한 보정을 전제로 한다.