• Title/Summary/Keyword: Digital Switchgear

Search Result 23, Processing Time 0.045 seconds

Construction of 154kV Intelligent Substation for Verification Test (154kV급 실증시험용 인텔리전트 변전소 구축)

  • Chung, Y.H.;Kim, J.B.;Lee, H.S.;Choi, I.H.;Lee, D.I
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.661-662
    • /
    • 2007
  • We have carried out the construction of the 154kV intelligent substation with KEPRI. The intelligent substation is built in Gochang testing facility of KEPCO and consists of electronic instruments for GIS(gas insulated switchgear), digital control panel, remote monitoring and diagnosis system, and digital relay system. Rogowski coil type CT(RCT) and capacitive voltage divider(CVD) are introduced compared with the instrument transformer of conventional type. Digital control panel(DCP) replaces the LCP(local control panel) which is drived for mechanical operation. For the monitoring of the condition of GIS and TR, various sensors are used. In this paper, we mention the synopsis and report the progress state of project.

  • PDF

The Development of ASS Controller Using DSP (DSP를 이용한 자동고장구분개폐기의 제어장치 개발)

  • Woo, Chun-Hee;Han, Tae-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.142-147
    • /
    • 2004
  • In this study, We developed the microprocessor based controller for Auto Section Switch(ASS). This is installed at consumer's medium-high voltage(load capacity is below 4,000 kVA) switchgear. This function is cooperate with protection device of fault section and automatically dividing the section. And It is designed by Air putter type extinction structure and adopt the mechanism and breaking part module of existing Load Breaker Switch. In addition, We successfully conducted the operation test and checked main function of proto-type.

Electrical Fire Warning Fuzzy System for Measured Power Informations (계측된 전력정보를 이용한 전기화재 경보 퍼지 시스템)

  • Cho, Do-Hyeoun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.189-193
    • /
    • 2013
  • In this paper, in order to predict and prevent electrical fires that occur in the power system, we measured the informations of electric power, and then proposed a system to predict the electrical fire using these informations. To this end, we analyzed the correlations for over-current, overload and overheating. These states are caused by the grounding current and the leakage current, and are the main causes of an electrical fire. Use these correlations to derive the derivative of the fuzzy rules for membership function. The designed algorithm was simulated by utilizing the informations of the actual power of the switchgear-panel.

A study of Partial Discharge Condition Monitoring Equipment In the Ultra High Voltage Gas-Insulated Switchgear(GIS) for Digital Sub-station application (디지털 변전소 적용을 위한 초고압 GIS 부분방전 상태감시장치 개발 연구)

  • Kim, Young-Noh;Cho, Young-Jun;Choi, Chul-Gang;Hwang, Chul-Min;Choi, Jae-Ok;Gang, Chang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1380-1381
    • /
    • 2008
  • By applying the digital sub-station, the change of various protect and measuring equipments has been applying. This paper is analyzed that the development of GIS partial discharge condition monitoring equipment is suited to the electricity IT technology and digital sub-station. It's constitution apply to be able to suit the data to high rank for GIS partial discharge condition monitoring equipment that is suited digital sub-station and Watch-dog module that be able to monitor the inner communication of the GIS partial discharge equipment. And then it also be able to apply of GIS partial discharge equipment when digital sub-station is applied.

  • PDF

A Study about International Standard of Digital Controlled CT (디지탈 제어용 CT의 국제규격(IEC 60044-8)에 대한 검토)

  • Chung, Y.H.;Kim, J.B.;Song, W.P.;Kim, D.S.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1794-1796
    • /
    • 2002
  • Conventional current transformers possess many qualities due their simplicity. However, the technological innovations now underway in the field of switchgear and substation control systems tends to underline their drawbacks. New technologies must be developed to provide users with better service quality in terms of precision, operating safety and interoperability. The current transformer presented combines simplicity and the high degree of precision offered by Rogowski coils with the processing possibilities of digital electronics.

  • PDF

Development of Partial Discharge Measuring System Module by use of Wide and Narrow Band (광대역 및 협대역을 동시에 사용하는 부분방전 측정 시스템 모듈 개발)

  • Lee, Jong Oh;Yu, Kyoung-Kook;Shin, In-Kwon;Chang, Doc-Jin;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.98-103
    • /
    • 2015
  • Power plant is that very high reliability when industrial and economic impact on the overall electric power system is required, it is essential to improve the reliability, especially the fault prediction diagnosis. Since an accident caused by the partial discharge in the power plant is above state has a faster response characteristic than the other indications in the case of any, the partial discharge generated in the power plant immediately detect the deterioration of insulation due to the accident of the power plant and the non-drawn It should prevent or reduce. Partial Discharge Measuring Systems for UHV SF6 Gas Insulated Switchgear and power transformer on site installed has some probability of abnormal recognition in case of non-flexible deal with on site noise. Many methode to eliminate these kinds of noises, UHF Detection System is chosen as purchase description in Korea, but this system having a bandwidth between 500MHz 1.5GHz wide band. Initial install periods(about 20 years ago), this band had no strong signal source, but in these days this wide band have strong signals, such as LTE. So, module described in this paper is designed as simultaneously use with wide and narrow band for solve this noise problem, and introduce this system.

A developments of inexpensive GIS partial discharge diagnostic system using the 9 Channel UHF sensors (9채널 UHF 센서를 적용한 염가형 GIS 부분방전 진단 시스템 개발)

  • Kim, Hong-Seok;Oh, Jae-Hun;Hong, Jung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2021-2022
    • /
    • 2008
  • UHF기법을 적용한 GIS 부분방전 진단 시스템은 가스절연 개폐장치(GIS: Gas Insulated Switchgear) 내부에서 발생하는 부분방전 신호를 측정하여 부분방전 원인을 진단한다. 이러한 부분방전 진단 시스템은 부분방전 신호를 UHF 대역의 고주파/위상 영역에서 분석하여 Digital 신호로 변환하기 때문에 고가의 분석 장비가 필요하므로 시스템의 설치 및 유지 보수비용이 많다. 따라서 부분방전 진단 시스템의 설치에 대하여 대중화하기 어려우며 GIS의 이상 상태가 발생하기 전에는 측정 데이터의 활용이 미비하다. 본 논문에서는 이러한 부분방전 시스템의 설치비용을 절감하고자 센서의 측정을 시간별로 변경하여 측정하는 염가형 부분방전 진단 시스템의 구성에 대하여 기술하며 대용량 데이터의 관리 방안에 대하여 기술한다.

  • PDF

Development of Rogowski-Coil Type CT for Application in 170kV GIS (170kV GIS용 Rogowski coil형 CT개발)

  • Chung, Y.H.;Kim, J.B.;Song, W.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.479-481
    • /
    • 2001
  • Traditionally, instrument transformer of the ferromagnetic core type have been used for measuring current in GIS(Gas Insulated Switchgear). Recently, with the introduction of digital technology at the protection relay or measurement device level, the use of new current sensor can be foreseen. Current measurement by means of Rogowski coil is just one illustration of this. This paper describes the progress of development of Rogowski-coil type CT for application in 170kV GIS.

  • PDF

Development of Current and Voltage Sensors for Distribution switchgears (로고스키 코일과 저항 분압기 원리를 이용한 배전급 전류/전압 센서 개발)

  • Choe, W.J.;Sohn, J.M.;Lee, B.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.888-890
    • /
    • 2003
  • In the distribution networks, it is required to develop compact and smart current and voltage sensors for compact and digital switchgears. The sensor developed newly adopt the priciple of rogowski coil for current sensing and resistive voltage divider for voltage sensing. The sensing characteristics and reliabilities were improved compared to conventional ones. In the near future, these voltage and current sensing apparatus will be widely used with electronic protection units for the distribution switchgear.

  • PDF

The Arc Fault Determination Method for the Electric Fire Prevention (전기화재 방지를 위한 아크고장 판단기법에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • The arc-fault occurring in the customer system becomes the direct cause of electric fire. However, it is very difficult to identify the arc-fault using the existing fault detection mechanism because the magnitude of the fault current is very small. Accordingly, this paper analyzes the causes of arc fault and designs the basic detection mechanism of arc fault. And then, it proposes an signal processing-based arc-fault determination methodology which can enhance the of accuracy of the arc-fault determination by applying DFT/DWT to the voltage and current waveform. Finally, this paper showed the application methodology of the proposed signal processing based fault determination method by applying and analyzing DFT/DWT to an high voltage in-rush current waveform.

  • PDF