일반촬영을 위한 셀레늄 기반의 엑스선 검출기 시스템 (System of a Selenium Based X-ray Detector for Radiography)

  • 이동길;박지군;최장용;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.817-820
    • /
    • 2002
  • Amorphous selenium based flat panel detectors convert incident x-ray to electric signal directly. Flat panel detectors gain more interest real time medical x-ray imaging. TFT array and electric readout circuits are used in this paper offered by LG.Philips.LCD. Detector is based on a $1536{\times}1280$ array of a-Si TFT pixels. X-ray conversion layer(a-Se) is deposited upper TFT array with a $400{\mu}m$ by thermal deposition technology. Thickness uniformity of this layer is made of thickness control system technology$({\leq}5%)$. Each $139{\mu}m{\times}139{\mu}m$ pixel is made of thin film transistor technology, a storage capacitor and collecting electrode having geometrical fill factor of 86%. This system show dynamic performance. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system.

  • PDF

The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

  • Miri, Shimasadat;Mehralizadeh, Sandra;Sadri, Donya;Motamedi, Mahmood Reza Kalantar;Soltani, Parisa
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.141-145
    • /
    • 2015
  • Purpose: This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods: Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections $5{\mu}m$ in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (${\alpha}=0.05$). Results: Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion: The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy.

A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.

증강현실형 치과방사선촬영 시뮬레이터의 개발 및 효과검증 : 자아효능감, 학습흥미도, 학습몰입도, 실습만족도를 중심으로 (Effects of a New Clinical Training Simulator for Dental Radiography using Augmented Reality on Self-efficacy, Interest in Learning, Flow, and Practice Satisfaction)

  • 구자영;이재기
    • 디지털콘텐츠학회 논문지
    • /
    • 제19권9호
    • /
    • pp.1811-1817
    • /
    • 2018
  • 증강현실기술에 기반하여, 구강방사선촬영 실습에 활용할 수 있는 새로운 임상시뮬레이터를 개발하였고, 이에 대한 효과를 검증하였다. 이 시뮬레이터를 사용한 실험집단과 기존의 텍스트 형식 교재를 사용한 통제집단으로 구분하여, 국내 치위생학과 학생 217명에 대해 설문조사 및 통계분석을 시행하였다. 증강현실형 시뮬레이터를 사용한 실험집단에서 자아효능감, 학습흥미도, 학습몰입도, 실습만족도가 높게 나타났다. 이를 통해, 증강현실형 치과방사선촬영 시뮬레이터가 구강방사선촬영 실습에 효과적인 학습매체로 활용할 수 있으며, 학습자의 임상실무역량 강화에 도움을 줄 수 있을 것으로 기대한다.

Thermal Characteristics of Rotating Anode X-ray Tube with Emissivity in Aging Process for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.125-131
    • /
    • 2015
  • We investigated the thermal characteristics of rotating anode X-ray tube to develop it for digital radiography by using computer simulation. The target which is the area of the anode struck by electrons is the most important component to get a long life of X-ray tube. So we analyze the thermal characteristics of the target and rotor assembly according to their emissivity by using ANSYS transient thermal simulation and then compare with the measured data of the target temperature operating in aging process of X-ray tube. Especially, keeping the lead coated layer as the role of metal lubricant on ball bearing enables to prevent the noise in rotating anode. The simulation result showed that its temperature was under the melting point of the lead in X-ray tube for digital radiography with 1.2 mm large focal spot 0.6 mm small focal spot and 150 kV tube voltage. We also investigated the relationship between the diameter of the anode shaft and the temperature of the anode and rotor assembly. It has been confirmed that the smaller anode shaft could be good for the rotor thermal characteristics.

고정 그리드를 사용한 디지털 방사선 영상에서 1차원 필터에 기초한 왜곡의 제거 (Artifact Reduction in Digital Radiography Images with the Stationary Grid Based on 1-Dimensional Filters)

  • 김동식
    • 대한전자공학회논문지SP
    • /
    • 제47권5호
    • /
    • pp.117-126
    • /
    • 2010
  • 산란선을 흡수하여 보다 선명한 x선 영상을 얻기 위하여 산란방지 그리드를 사용하여 투사영상을 얻는데, 이때 그리드로 인한 왜곡이 발생한다. 본 논문에서는 회전된 그리드를 사용하여 투사영상을 얻고 단순한 1차원 저역필터를 영상의 공간영역에서 각 축으로 별도로 적용하여 그리드 왜곡을 효율적으로 제거하는 방법을 제안하고 그 성능을 고찰해 보았다. 제안한 방법은 왜곡 주파수를 별도로 예측할 필요 없이, 회전된 그리드를 사용하여 획득한 영상에 단순한 1차원 필터를 주파수영역이 아닌 공간영역에서 적용하므로 매우 단순하여 쉽게 구현이 가능하며 빠른 계산 속도를 가지는 장점을 가지고 있으면서 그 성능은 주파수영역에서 2차원 필터를 적용한 경우와 유사하다.

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단 (Proximal caries detection using digital subtraction radiography in the artificial caries activity model)

  • 박정훈;최용석;황의환;이기자;최삼진;박영호;김경숙;진현석;홍경원;오범석;박헌국
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods: Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. Results: In artificial caries activity model, the range of lesional depth was $572-1,374{\mu}m$ and the range of lesional area was $36.95-138.52mm^2$. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. Conclusion: The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  • PDF

엑스선촬영 각도를 측정할 수 있는 장치 개발과 흉부 X선 영상촬영에서의 적용 (Development of portable digital radiography system with device for sensing X-ray source-detector angle and its application in chest imaging)

  • 김태훈;허동운;류종현;정창원;전홍영;김규겸;홍지민;장미연;김대원;윤권하
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2017년도 제55차 동계학술대회논문집 25권1호
    • /
    • pp.235-238
    • /
    • 2017
  • This study was to develop a portable digital radiography (PDR) system with a function measuring the X-ray source-with-detector angle (SDA) and to evaluate the imaging performance for the diagnosis of chest imaging. The SDA device consisted of an Arduino, an accelerometer and gyro sensor, and a Bluetooth module. According to different angle degrees, five anatomical landmarks on chest images were assessed using a 5-point scale. Mean signal-to-noise ratio and contrast-to-noise ratio were 182.47 and 141.43. Spatial resolution (10% MTF) and entrance surface dose were 3.17 lp/mm ($157{\mu}m$) and 0.266mGy. The angle values of SDA device were not significant difference as compared to those of the digital angle meter. In chest imaging, SNR and CNR values were not significantly different according to different angle degrees (repeated-measures ANOVA, p>0.05). The visibility scores of the border of heart, 5th rib and scapula showed significant differences according to different angles (rmANOVA, p<0.05), whereas the scores of the clavicle and 1st rib were not significant. It is noticeable that the increase in SDA degree was consistent with the increase of visibility score. Our PDR with SDA device would be useful to be applicable to clinical radiography setting according to the standard radiography guideline at various fields.

  • PDF