• Title/Summary/Keyword: Digital PID Controller

Search Result 151, Processing Time 0.046 seconds

Experimental Characteristics of the Electro-Pneumatic Proportional Modulator (비례 모듈레이터 특성)

  • Yun S.;Choi B.O.;Kim C.Y.;Park P.W.;Lee G.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1784-1787
    • /
    • 2005
  • In this paper, proportional modulator which controls the second pressure of the pneumatic system was studied and proportional operating of modulator was gotten by two digital valves that have a fast dynamic characteristics and were controlled by PWM operating method. In order to more precision pressure control, this modulator consist of not only high speed two digital valves but also pressure sensor, measurement equipment and controller having a microprocessing function. In this study, for the development of the new proportional modulator, various research such as PWM control method, test equipment manufacturing, testing and evaluation were accomplished.

  • PDF

Design of fuzzy speed/phase controller for drum motor in home VCR (VCR용 드럼 모터의 퍼지 속도/위상 제어기 설계)

  • 박귀태;이기상;박태홍;배상욱;이상락
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.457-462
    • /
    • 1991
  • Recently, digital techniques have been applied to servo systems of the home VCR, which result in high accuracy, high stability and a small number of parts required. The servo systems are now becoming more compex because the latest home VCRs are stringly required to have many functions. Given these circumstances, software servo concepts were introduced to the VCR servo system with microprocessor. But there are some difficulties in the conventional digital PID controller, eg. caculating the exact gains or dynamics. In this paper, we introduce FLC(Fuzzy Logic Controller) to the speed/phase control for VCR drum motor. To show the usefulness of the proposed controller, some studies are discussed by simulation and experiment.

  • PDF

JOINT POSITION COMTROL SYSTEM FOR FARA ROBOTS OF SAMSUNG ELECTROICS

  • Kim, Hyo-Kyu;Kim, Dong-Il;Kim, Sungkuwn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.913-916
    • /
    • 1990
  • In this paper, attempts have been made to control AC synchronous servo motor used as actuators of joints of the FARA robot with high dynamic performance and precise positioning. The AC synchronous servo motors used in FARA robots have resolves as position sensors. Resolver to digital converters are used in order to obtain the information of rotor speed and position from resolver outputs. The proposed joint position control system consists of four speed controller and one position controller. Analog methods are used in the position controller, while digital methods are used in the position controller. For precise position control, PID control algorithm and interpolation functions are executed in two 16 bit microprocessors with sampling rate 2ms. Experimental results show that the proposed joint position control system can be effectively applied to industrial robots in order to obtain high dynamic performance and precise positioning. The proposed joint position control system is being used in the control of FARA robots of Samsung Electronics.

  • PDF

A Study on a Digital Amplifier.Controller for Proportional Control Valve (비례제어밸브용 디지털 앰프.컨트롤러에 대한 연구)

  • Lee, J.C.;Koh, J.U.;Kwon, T.H.;Shin, H.B.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2011
  • This study presents the design of digital amplifier.controller for a proportional control valve and the development of PID discrete control scheme by using RCP(Rapid Controller Prototyping) system. RCP system is the device to embed the control code developed in PC into the microcontroller on-site. Ramp input test using the digital amplifier.controller developed in this study was carried out for the proportional control valve of domestic production and Bosch Rexroth respectively. The instability problem occurred around maximum displacement of localized valve spool at ramp input test was solved by supplementing offset current to the duty ratio of PWM(Pulse Width Modulation) driving signal to the solenoid. The comparison of test results between localized proportional control valve and Bosch Rexroth's product shows that the characteristics obtained by ramp input test and static flow gains are alike each other. Two valves are about the same in dead bands and hysteresis characteristics.

The Improvement of Control Performance for a Magnetic Levitation System (자기부상 시스템의 성능개선)

  • Kim, Jong-Moon;Kang, Do-Hyun;Park, Min-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.864-866
    • /
    • 2003
  • In this paper, the improvement of control performance for a magnetic levitation system is presented. The model of a single-magnet system with rail is derived. As a conventional controller, PID controller is designed and implemented. This controller has a narrow stability margin due to low-order controller structure so that it cause unstability for a flexible rail. So to improve the control performance and stability margin, a robust controller as a new controller is designed and implemented using a VME-based digital controller. As a result, the controller performance of the new designed controller is better than that of the conventional controller.

  • PDF

Digital Linear Control System for a Magnetic Bearing System of a High Vacuum Turbomolecular Pump (고진공 터보 분자펌프용 자기베어링 시스템의 디지털 선형 제어시스템)

  • Ro, Seung-Kook;Kyung, Jin-Ho;Park, Jong-Kweon;Nam, Woo-Ho;Koh, Deug-Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.256-264
    • /
    • 2010
  • In this paper, a digital controller of magnetic bearing system for a high vacuum turbomolecular pump (TMP) is designed and examined. For stabilizing and providing damping in magnetic bearing, the digital PID controller is applied for each 5 control axes, and the inter-axis cross feedback controller is also applied to suppress low frequency vibration caused by gyroscopic moment of the rotor at high speed of rotation. The fabricated rotor-shaft has its first flexible natural frequency lower than maximum speed, about 614Hz, so the two lead filters are applied to increase damping of flexible mode. Notch filters with rotating frequency were selected to reduce vibration of the pump housing caused by unbalance load. The implemented controllers are verified by examination of frequency response and rotating test up to 40,000 rpm, which is higher than critical speed of backward flexible mode.

Remote Controller Design of networked Control System Using Genetic Algorithm (유전자 알고리즘을 이용한 네트워크 기반 제어 시스템의 원격 제어기 설계)

  • Lee, Kyung-Chang;Lee, Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.80-88
    • /
    • 2002
  • As many sensors and actuators are used in automated systems, various industrial networks are adopted for digital control system. In order to take advantages of the networking, however, the network implementation should be carefully designed to satisfy real-time requirements considering network delays. This paper presents the implementation scheme of a networked control system via Profibus-DP network. More specifically, the effect of the network delay on the control performance was evaluated on a Profibus-DP testbed, and a GA-based PID tuning algorithm is proposed to design controllers suitable for networked control systems.

Development of automatic flow control system based on LabView (LabView를 이용한 자동유량제어 시스템의 개발)

  • Kang, Tae-Won;Kim, Du-Seob;Ann, Sung-Gyu
    • Journal of Engineering Education Research
    • /
    • v.19 no.2
    • /
    • pp.3-7
    • /
    • 2016
  • A flow control system was designed and fabricated to control the flow rate of liquid through the pipe. This control system was composed of hardwares and software, hardwares as controller, gate valve, orifice meter and data aquisition board and software as National instruments Labview program. Control of flow rate was executed by adjusting the pneumatic valve located at the center of pipe line based on the control signal generated by LabView PID control algorithm, which converts analog signal measured by pressure difference of orifice to digital signal to adjust pneumatic valve. For the controller setup Ziegler-Nichols tuning technique was applied and control performances were investigated for not only the disturbance but also the set point changes. Developed system showed good control performances in flow control enough to use as teaching tool of feedback control theory and practice in university, and also as industrial application.

Design of A Neuro-Fuzzy Controller for Speed Control Applied to AC Servo Motor (AC 서보 모터의 속도 제어를 위한 뉴로-퍼지 제어기 설계)

  • Ku, Ja-Yl;Kim, Sang-Hun
    • 전자공학회논문지 IE
    • /
    • v.47 no.3
    • /
    • pp.26-34
    • /
    • 2010
  • In this study, a neuro-fuzzy controller based on the characteristics of fuzzy controlling and structure of artificial neural networks(ANN). This neuro-fuzzy controller has each advantage from fuzzy and ANN, respectively. Plus, it can handle their own shortcomings and parameters in the controller can be tuned by on-line. To verify the proposed controller, it has applied to the AC servo motor which is popular item in robot control field. General PID and fuzzy controller are also applied to the same motor so stability and good characteristic of the proposed controller are compared and proved. Especially, the experiment for variable load is investigated and performance result is proved also.

Systematic Design Method of Fuzzy Logic Controllers by Using Fuzzy Control Cell (퍼지제어 셀을 이용한 퍼지논리제어기의 조직적인 설계방법)

  • 남세규;김종식;유완석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1234-1243
    • /
    • 1992
  • A systematic procedure to design fuzzy PID controllers is developed in this paper. The concept of local fuzzy control cell is proposed by introducing both an adequate global control rule and membership functions to simplify a fuzzy logic controller. Fuzzy decision is made by using algebraic product and parallel firing arithematic mean, and a defuzzification strategy is adopted for improving the computational efficiency based on nonfuzzy micro-processor. A direct method, transforming the typical output of quasi-linear fuzzy operator to the digital compensator of PID form, is also proposed. Finally, the proposed algorithm is applied to an DC-servo motor. It is found that this algorithm is systematic and robust through computer simulations and implementation of controller using Intel 8097 micro-processor.