• Title/Summary/Keyword: Digital Measurement

Search Result 2,099, Processing Time 0.026 seconds

Types and Characteristics of Digital Anthropometric Methods (디지털 인체 계측 방법의 유형 및 특성)

  • Kim, Rira
    • Journal of Fashion Business
    • /
    • v.25 no.5
    • /
    • pp.88-98
    • /
    • 2021
  • In this study, the characteristics of digital anthropometric methods were determined with case studies. These methods were broadly classified into two categories: non-wearable and wearable. Then, these categories were further classified into four types: 3D Scanning, mobile app, smart clothing, and smart tool Among the non-wearable types, the "3D scanning" technique was based on the use of 3D hardware equipment. With this technique, the body shape was measured and the internal body information was obtained. Therefore, it is used in fields of healthcare and fitness. Among the wearable types, "Smart clothing" involves a special clothing that measures human body and a smartphone application. Both the components are linked to a fashion platform, which is based on the measured sizes that help shoppers. The "Smart tool" has the characteristic of measuring only with smart tools and smartphone applications; it does not involve the measurement of images. The common advantage of digital anthropometric methods are as follows: they reduce the time and cost of measurement by enabling self-measurement. Moreover, simple measurements are used to determine the size of anthropometry. Thereafter, it accumulates this data to track the continuous changes in size. From an industrial point of view, digital anthropometric technology should be used to increase sales. The on-demand market can be expanded as global consumers would throng the Korean fashion market. For the consumer, an avatar should be created to fit the user's size. This would provide a fun experience to the user.

A High-speed Digital Laser Grating Projection System for the Measurement of 3-dimensional Shapes

  • Park, Yoon-Chang;Park, Chul-Geun;Ahn, Seong-Joon;Kang, Moon-Ho;Ahn, Seung-Joon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.251-255
    • /
    • 2009
  • In the non-contact 3-dimensional (3D) shape measurements, the fringe pattern projection method based on the phase-shifting technique has been considered very effective for its high speed and accuracy. The digital fringe projector in particular has great flexibility in generating fringe patterns since the patterns can be controlled easily by the computer program. In this work, we have developed a high-speed digital laser grating projection system using a laser diode and a polygon mirror, and evaluated its performance. It has been demonstrated that all the optical measurements required to find out the profile of a 3D object could be carried out within 31 ms, which confirmed the validity of our 3D measurement system. The result implies the more important fact that the speed in 3D measurement can be enhanced remarkably since, in our novel system, there is no device like a LCD or DMD whose response time limits the measurement speed.

Assessment of Gradient-based Digital Speckle Correlation Measurement Errors

  • Jian, Zhao;Dong, Zhao;Zhe, Zhang
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.372-380
    • /
    • 2012
  • The optical method Digital Speckle Correlation Measurement (DSCM) has been extensively applied due its capability to measure the entire displacement field over a body surface. A formula of displacement measurement errors by the gradient-based DSCM method was derived. The errors were found to explicitly relate to the image grayscale errors consisting of sub-pixel interpolation algorithm errors, image noise, and subset deformation mismatch at each point of the subset. A power-law dependence of the standard deviation of displacement measurement errors on the subset size was established when the subset deformation was rigid body translation and random image noise was dominant and it was confirmed by both the numerical and experimental results. In a gradient-based algorithm the basic assumption is rigid body translation of the interrogated subsets, however, this is in contradiction to the real circumstances where strains exist. Numerical and experimental results also indicated that, subset shape function mismatch was dominant when the order of the assumed subset shape function was lower than that of the actual subset deformation field and the power-law dependence clearly broke down. The power-law relationship further leads to a simple criterion for choosing a suitable subset size, image quality, sub-pixel algorithm, and subset shape function for DSCM.

Measurement of Step Difference using Digital Holography of ITO Thin Film Fabricated by Sputtering Method (스퍼터링 공법으로 제작한 ITO 박막의 디지털 홀로그래피를 이용한 단차에 대한 측정)

  • Jung, Hyun Il;Shin, Ju Yeop;Park, Jong Hyun;Jung, Hyunchul;Kim, Kyeong-suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.84-89
    • /
    • 2021
  • Indium tin oxide (ITO) transparent electrodes, which are used to manufacture organic light-emitting diodes, are used in light-emitting surface electrodes of display EL panels such as cell phones and TVs, liquid crystal panels, transparent switches, and plane heating elements. ITO is a major component that consists of indium and tin and is advantageous in terms of obtaining sheet resistance and light transmittance in a thin film. However, the optical performance of devices decreases with an increase in its thickness. A digital holography system was constructed and measured for the step measurement of the ITO thin film, and the reliability of the technique was verified by comparing the FE-SEM measurement results. The error rate of the step difference measurement was within ±5%. This result demonstrated that this technique is useful for applications in advanced MEMS and NEMS industrial fields.

Computerized Measurement on Angular Parameters for Hallux Valgus: Comparison of 100% and 150% Magnified Digital Radiography (무지 외반증 각변형에 대한 디지털영상의 전산화 계측: 100%와 150% 확대영상에서의 계측비교)

  • Sung, Il-Hoon;Lee, Doo-Yeon;Sung, Chang-Ho;Seo, Woo-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • Purpose: To study computerized measurements of angular parameters on 100% and 150% resized digital radiography of hallux valgus deformity Materials and Methods: 30 digital radiography of standing foot anteroposterior view of hallux valgus patients were included. Two observers(A, B) independently measured hallux valgus angle (HVA), 1-2 intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) in two times on both 100%-size and 150% magnified images respectively, using computerized measurement software tools. The results were interpreted with the statistical software program, Statistical Analysis System, version 9.2. Results: In repeated measurements of each observer, measurements on 150% magnified image showed no differences of all three parameters and with 100%-size image, there were differences of HVA (observer A) and 1-2 IMA (observer B) (p>0.05). When testing interobserver reliability, both observers showed differences in measurement of HVA and DMAA (p<0.05), but no differences in measurement of 1-2 IMA in both images. Within the 95% confidence interval, limits of error of measurements between two observers on HVA, IMA and DMAA were $2.7^{\circ}$ $1.4^{\circ}$ and $5.0^{\circ}$ respectively in 100%-size images, and $2.6^{\circ}$, $1.6^{\circ}$ and $4.7^{\circ}$ respectively in 150% magnified images. Conclusion: In computerized measurements for angular parameters of hallux valgus with digital radiography, 150% magnified images showed intraobserver reliability. Both 100% and 150% magnified images failed to show interobserver reliability. Measurement of 1-2 IMA in both 100% and 150% images showed less interobserver error.

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.

Measurement of natural frequency of aluminum honeycomb sandwich beams using high speed digital cameras (고속 디지털 카메라를 이용한 알루미늄 하니콤 샌드위치 보의 고유 진동수 계측)

  • Goo, Nam Seo;Vang, Hoang My;Le, Vinh Tung;Jin, Tailie
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • In this study, we measured the natural frequencies of aluminum honeycomb sandwich beams using digital image correlation technique. The vibration images were captured using two high speed digital cameras and the images were converted to displacements by the digital image correlation technique. Displacement data in time domain were tranformed to frequency domain data by fast Fourier transform software. To reduce noise invoked by random exitation, a spectrum averaging technique and Savitsky-Golay digital filter were adopted. A conventional vibration measurement using an accelerometer and a finite element analysis were performed to compare the results by high speed digital camera measurement method. In conclusion, new method using high speed digital cameras and digital image correlation technique can measure the vibration of beam structures and can be applied to bio-structures where sensors cannot be attached.

Dysfunction of Digital Leisure of ICT Age and Educational Measurement (ICT 시대의 디지털 여가 역기능과 교육대책)

  • Kim, Myeong-Mi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1979-1984
    • /
    • 2013
  • As digital leisure's activity increase recently, the worry for side effect except right function occurs with reality. In this paper, the importance of leisure, participation effect when someone has a chance to leisure is reviewed. The dysfunction of digital leisure that focuses on usage of the digital device in information society is examined. In order to solve those dysfunction, the measure is presented through education and convergence.

Precision of Digital Photogrammetry for the Roughness Measurement of Rock Surfaces

  • Lee, Hyo-Sung;Ahn, Ki-Won;Park, Byung-Uk;Kim, Yong-Il
    • Korean Journal of Geomatics
    • /
    • v.3 no.1
    • /
    • pp.43-51
    • /
    • 2003
  • This paper presents the benefits of using close-range digital photogrammetric techniques for measuring the roughness of rock surfaces, using digital stereo images obtained from a Rolleiflex 6006 metric camera. To precisely measure surface roughness, we researched on how to use the flat and curved reference surface obtained from geometrically corrected digital images of the rock surface by using the least squares method. To test the precision of the proposed technique, the surface roughness has been measured between the reference surface and sample areas of very smooth-surfaced rock. Then the results were compared with the measurements obtained from a laser sensor profilometer.

  • PDF

Development of Digital Vacuum Pressure Sensor Using MEMS Analog Pirani Gauge

  • Cho, Young Seek
    • Journal of information and communication convergence engineering
    • /
    • v.15 no.4
    • /
    • pp.232-236
    • /
    • 2017
  • A digital vacuum pressure sensor is designed, fabricated, and characterized using a packaged MEMS analog Pirani gauge. The packaged MEMS analog Pirani gauge requires a current source to heat up a heater in the Pirani gauge. To investigate the feasibility of digitization for the analog Pirani gauge, its implementation is performed with a zero-temperature coefficient current source and microcontroller that are commercially available. The measurement results using the digital vacuum pressure sensor showed that its operating range is 0.05-760 Torr, which is the same as the measurement results of the packaged MEMS analog pressure sensor. The results confirm that it is feasible to integrate the analog Pirani gauge with a commercially available current source and microcontroller. The successful hybrid integration of the analog Pirani gauge and digital circuits is an encouraging result for monolithic integration with a precision current source and ADCs in the state of CMOS dies.