• Title/Summary/Keyword: Digital Hospital

Search Result 1,338, Processing Time 0.028 seconds

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading

  • Tavakolizadeh, Sara;Vafaee, Fariborz;Khoshhal, Masume;Ebrahimzadeh, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.191-198
    • /
    • 2015
  • PURPOSE. The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS. Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch's category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS. All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was $0.6{\pm}0.67$ mm in the first group and $0.6{\pm}0.51$ mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION. This preliminary one-year result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.

Study on image quality and dosage comparison of F/S system and DR system (F/S시스템과 DR시스템의 화질과 피폭선량 비교에 관한 검토)

  • Kim, Sun-Chil;Jung, Jae-Eun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.7-11
    • /
    • 2003
  • Currently, many hospitals are hastening to introduce digital radiography systems. This is a direct result of the intentions to improve medical services and to digitalize radiology information systems, and is also leading to the improvement of medical imaging technology. Throughout F/S system's long history, many people have researched the image quality and dosage concerning these systems, and as a result, huge improvements in the dosage of patients were possible. Similarly, I believe that DR systems need the same kind of effort. Of course, decreases in dosage that ignore image quality are unthinkable. The results of experiments conducted by five hospitals during a period of 3 months brought to us the conclusions listed below. 1. Based on the comparison and analysis of the exposure control of F/S systems and DR systems, DR systems generally showed higher exposure control for parts of the phantom that became thicker, and the exposure control improved rapidly as the thickness increased. 2. DR systems still proved to be somewhat deficient in resolution measurements compared to existing F/S systems. The image processing part of DR systems contributed much to these result. 3. Under conditions used clinically, the dosage measurements of DR systems were generally higher regardless of region. 4. According to the evaluation of image quality, DR systems showed a higher degree of satisfaction as the thickness of the region became thinner. As mentioned above and based on the mutual relationship experiments between the dosage and image quality of F/S systems and DR systems, research to increase the satisfaction of DR systems must be considered.

  • PDF

Clinical evaluation of Acupuncture on Herniated of Cervical Intervertebral Disc by DITI (컴퓨터 적외선(赤外線) 전신체열촬영(全身體熱撮影)으로 본 경추추간판(頸椎椎間板) 탈출증(脫出症)의 침구치료효과(鍼灸治療效果))

  • Lee, Geon-Mok
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.132-140
    • /
    • 1995
  • Object : This study is designed to evaluate the correlation between the data of DITI(Digital Infrared Thermographic Imaging)examination and the changes of clinical symptom after the therapy of acupuncture in the patients with herniated cervical intervertebral disc. Content : The conservative therapy with acupuncture was performed during $4{\sim}5$ weeks, The acupuncture points of SI3, B62, TE3, G34, LI4, S36, GV26, G21, SII5 were used. In the pre- and post therapy, DITI examinations were performed in patients who had HIVD and were treated by acupuncture simultaneously, and then tried to correlate the results of clinical symptoms with the difference of thermographic findings at pre-acupuncture and post-acupuncture. Setting : The standard routine thermoghaphic examinations were performed with thermography(DITI) in the 15 patients with lumbar disc herniations at pre- and post acupuncture. Patient : Thermographic imaging of 15 cases were analyzed. They has disc herniations in X-ray, CT scan and MRI and they were treated by acupuncture theraphy in our hospital from March, 1994 to January, 1995. Result : 1) The causes were trauma(60%), retention of phlegm and fluid(8.7%) and cold & moisture(33.3%) 2) Levels of herniated cervical disc are C2/3(1 case). C3/4(2 cases), C5/6 & C6/7 (2 cases), C6/7(4 cases), Normal(6 cases). 3) Classifications of thermographic pattern are radiculopathy(80%), spot(13.3%), and nonspecific(6.7%) in order. 4) In evaluation Results of clinical symptom are Excellent(80%), Good(6.7%), and Poor(6.7%). Data of DITI are Excellent(80%), Good(6.7%), Fair(6.7%), and Poor(6.7%). Conclusion ; Acupuncture showed good results over 86.7% in clinical evaluation and 86.7% in DITI. Thermographic examination was valuable in the evaluation of therapeutic effect of acupuncture treatment.

  • PDF

Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia (초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발)

  • Kim, T.H.;Chun, S.I.;Han, Y.H.;Kim, D.H.;Mun, C.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

Design and Experiment of a Micro Electronic System for Prediction of Alveolar-Gas Partial Pressures

  • Kim, Da-Jung;Chang, Keun-Shik;Kim, Sa-Ji;Park, Hye-Yun;Suh, Gee-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.187-193
    • /
    • 2010
  • In this study we have designed and fabricated an inexpensive micro electronic system that we call Alvitek. It can indirectly but accurately predict and display the partial pressures of alveolar oxygen and carbon dioxide for the patients in the ICU of a hospital. Alvitek consists of both hardware part and software part. Performance of the system is tested by animal experiment with pigs for various $F_{t}e_{2}$ and RR(Respiratory Rate) values under the mechanical ventilation. The predicted alveolar gas partial pressures are cprpared with the approximate alveolar oxygen partial pressures easily calculated by the physician’s bedside formula. As a result, we have concluded that the relative error of A-$aDe_2$ calculated by the bedside formula grows seriously for lower $F_{t}e_{2}$ values. The present prediction method of Alvitek is henceforth believed very meaningful to the physicians. The system hardware and software are described in the text.

A study of DDS Middleware based Multimedia PACS Data Transmission Scheme for QoS in Hospital Network (병원 전산망에서 QoS보장을 위한 DDS 미들웨어 기반 멀티미디어 PACS 데이터 전송 기법 연구)

  • Kim, Nam-Ho;Seung, Teak-Young;Lee, Suk-Hwan;Lee, Jong-Keuk;Kwon, Ki-Ryong
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.462-463
    • /
    • 2012
  • 팍스시스템은 의료 영상을 디지탈화한 시스템이다. PACS데이터는 초창기 CR(Computed Radiography)의 경우 10MB내외의 데이터를 발생하였으나 의료장비의 발전으로 인해 DB(Digital Radiography)는 20MB이상의 데이터를 발생하였다. 또 CT(Computed Tomography)의 경우 0.5MB데이터를 100Slice내외의 데이터를 발생하였으나, 현재는 Cardiac/PET 등의 CT는 Multi Frame을 지원하며 300~5000Slice이상의 데이터를 발생하게 됨에 따라 네트워크에 상당한 트래픽이 발생하여 병원 진료 환경에 심각한 영향을 초래한다. 또한, 스마트 폰, 태블릿 pc등의 발전으로 인해 많은 사용자들은 실시간 또는 멀티미디어와 같은 데이터 표현 방식으로 팍스 데이터를 보길 원할 것이며, 팍스 시스템 또한 그러한 요구조건을 만족시키기 위해 발전하고 있다. 병원에서 사용하는 네트워크는 인터넷 서비스의 모토인 best effort방법을 일반적으로 사용한다. 이러한 데이터 전송방식은 진료에 직접적인 영향을 미치는 팍스 데이터의 전송에 영향을 미칠 수 있다. 특히 네트워크의 트래픽이 제한적인 환경에서 높은 대역폭을 요구하는 멀티미디어 팍스 데이터를 다수의 사용자들이 전송받기 원하면 지연시간으로 인해 원활한 진료진행을 방해 받을 수 있다. 이러한 문제를 해결하기 위해 네트워크 개발자들은 QoS라는 개념을 도입하였고, 여러 계층에서 QoS를 보장하기 위한 연구가 진행되였다. 일반적으로, 네트워크에서 QoS를 지원하기 위한 여러가지 형태의 연구들을 조사하고, 분산 시스템을 제어하기 위한 DDS 미들웨어에 대한 연구를 기반으로 병원 네트워크에서 적용 방안을 설계하고 시뮬레이션을 통해 검증함으로써 새로운 형태의 병원 네트워크를 제안하고자 한다.

  • PDF

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

  • Kim, Mi-Ja;Huh, Kyung-Hoe;YI, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.25-33
    • /
    • 2012
  • Purpose : This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods : MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results : All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion : Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

Prostate Cancer Incidence in Turkey: An Epidemiological Study

  • Zorlu, Ferruh;Divrik, Rauf Taner;Eser, Sultan;Yorukoglu, Kutsal
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9125-9130
    • /
    • 2014
  • Background: This study aimed to determine the incidence of prostate cancer in Turkey in a population-based sample, and to determine clinical and pathological characteristics of the cases. Materials and Methods: All newly diagnosed prostate cancer patients were included in this national, multi-centered, prospective and non-interventional epidemiological registry study conducted in 12 cities representing the 12 regions of Turkey from July 2008 to June 2009. The population-based sample comprised 4,150 patients with a recent prostate cancer diagnosis. Results: Age-adjusted prostate cancer incidence rate was 35 cases per 100,000 in Turkey. At the time of diagnosis, median age was 68, median PSA level was 10.0 ng/mL. Digital rectal examination was abnormal in 36.2% of 3,218 tested cases. Most patients had urologic complaints. The main diagnostic method was transrectal ultrasound guided biopsy (87.8%). Gleason score was ${\leq}6$ in 49.1%, 7 in 27.8% and >7 in 20.6% of the cases. There was a statistically significant positive correlation between serum PSA level and Gleason score (p=0.000). The majority of patients (54.4%) had clinical stage T1c. Conclusions: This is the first population-based national data of incidence with the histopathological characteristics of prostate cancer in Turkey. Prostate cancer remains an important public health concern in Turkey with continual increase in the incidence and significant burden on healthcare resources.