• 제목/요약/키워드: Digital Dentistry

검색결과 844건 처리시간 0.029초

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

  • Katheng, Awutsadaporn;Kanazawa, Manabu;Komagamine, Yuriko;Iwaki, Maiko;Namano, Sahaprom;Minakuchi, Shunsuke
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.45-55
    • /
    • 2022
  • PURPOSE. This in vitro study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. MATERIALS AND METHODS. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). RESULTS. The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group (P < .05). For precision, this was significantly different from those of other groups (P < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. CONCLUSION. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.

Sex Determination Using a Discriminant Analysis of Maxillary Sinuses and Three-Dimensional Technology

  • Jeong-Hyun Lee;Hee-Jeung Jee;Eun-Seo Park;Seok-Ho Kim;Sung-Suk Bae
    • 치위생과학회지
    • /
    • 제22권4호
    • /
    • pp.249-255
    • /
    • 2022
  • Background: Sexual dimorphism is important for sex determination in the field of forensics. However, sexual dimorphism is commonly assessed using cone beam computed tomography (CBCT) rather than three-dimensional (3D) modeling software; therefore, studies using a more accurate measurement approach are necessary. This study assessed the sexual dimorphism of the MS using a 3D modeling program to obtain information that could contribute to the fields of surgery and forensics. Methods: The CBCT data of 60 patients (age, 20~29 y; 30 males and 30 females) admitted to the Department of Orthodontics at the Dankook University School of Dentistry were provided in Digital Imaging and Communications in Medicine (DICOM) format. The left MS and right MS were modeled based on the DICOM files using the Mimics (version 22; Materialise, Leuven, Belgium) 3D program and converted to stereolithography (STL) files used to measure the width, length, and height of the MS, infraorbital foramen (IOF), right MS, and left MS. The average of three repeated measurements was calculated, and a reliability test was performed to ensure data reliability (Cronbach's α=0.618). A canonical discriminant analysis was performed using a standard approach (left: Box's M=0.096; right: Box's M=0.115). Results: Males had greater values for all parameters (MS width, MS length, MS height, IOF, right MS, left MS) than females. The discriminant analysis identified six independent variables (MS width, MS height, MS length, IOF, right MS, left MS) that could identify sex. The left MS and right MS correctly identified the sex of 81.7% and 71.7% of the patients, respectively, with the left MS having higher accuracy. Conclusion: This study confirmed that, for Korean individuals, the left MS has a better ability to identify sex than the right MS. These results may contribute to sex identification in the fields of surgery and forensics.

SLM 방식으로 제작한 도재관 금속하부구조물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal fit of metal copings fabricated by selective laser melting)

  • 배성령;이하빈;노미준;김지환
    • 대한치과기공학회지
    • /
    • 제45권1호
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: To evaluate the marginal and internal fit of metal coping fabricated by a metal three-dimensional (3D) printer that uses selective laser melting (SLM). Methods: An extraoral scanner was used to scan a die of the prepared maxillary right first molar, and the coping was designed using computer-aided design software and saved as an stereo lithography (STL) file. Ten specimens were printed with an SLM-type metal 3D printer (SLM group), and 10 more specimens were fabricated by casting the castable patterns output generated by a digital light processing-type resin 3D printer (casting the 3D printed resin patterns [CRP] group). The fit was measured using the silicon replica technique, and 8 points (A to H) were set per specimen to measure the marginal (points A, H) and internal (points B~G) gaps. The differences among the groups were compared using the Mann-Whitney U-test (α=0.05). Results: The mean of marginal fit in the SLM group was 69.67±18.04 ㎛, while in the CRP group was 117.10±41.95 ㎛. The internal fit of the SLM group was 95.18±41.20 ㎛, and that of the CRP group was 86.35±32 ㎛. As a result of statistical analysis, there was a significant difference in marginal fit between the SLM and CRP groups (p<0.05); however, there was no significant difference in internal fit between the SLM group and the CRP group (p>0.05). Conclusion: The marginal and internal fit of SLM is within the clinically acceptable range, and it seems to be applicable in terms of fit.

Evaluation of Sex and Age Factors Contributing to the Diagnosis of Oral Frailty in Community-Dwelling Older Adults

  • Eun-Ha Jung;Sun-Young Han
    • 치위생과학회지
    • /
    • 제23권4호
    • /
    • pp.378-388
    • /
    • 2023
  • Background: With increasing interest in health in old age, aspects of oral aging are being considered. The Korean Academy of Geriatric Dentistry recently proposed the diagnostic criteria for oral frailty in older adults in Korea. This study aimed to conduct a cross-sectional survey of factors related to oral frailty among community-dwelling older adults and identify differences in oral frailty status according to age and sex. Methods: Among 217 older adults aged ≥60 years who visited a senior center in Wonju, 206 completed all tests for oral frailty. Among them, data from those with a Korean Version of the Modified Barthel Index score ≥90 were used in the final analysis. After evaluating oral frailty diagnostic factors such as chewing ability, occlusal force, tongue pressure, oral dryness, oral cleanliness, and swallowing function, oral hypofunction was determined according to the oral frailty diagnostic criteria. Subsequently, the evaluation results were compared based on sex and age. Results: Significant differences in chewing ability, maximum occlusal pressure, and maximum tongue pressure were observed between sexes. However, these differences did not affect oral frailty diagnosis. All diagnostic factors of oral frailty, except for the risk of oral dryness and swallowing dysfunction, showed significant differences with age. However, no significant difference was observed in the prevalence of oral frailty. Additionally, this study found no relationship between sex and oral frailty factors using the oral frailty diagnostic criteria. However, it also found that age plays a significant role as an oral frailty diagnostic indicator, in addition to oral dryness and swallowing function. Conclusion: Sex and age did not affect oral frailty diagnosis. However, patients' chewing ability, occlusal force, and tongue pressure were affected by sex and age. Therefore, sex and age should be considered when diagnosing and intervening in oral frailty in the future.

Convolutional neural network of age-related trends digital radiographs of medial clavicle in a Thai population: a preliminary study

  • Phisamon Kengkard;Jirachaya Choovuthayakorn;Chollada Mahakkanukrauh;Nadee Chitapanarux;Pittayarat Intasuwan;Yanumart Malatong;Apichat Sinthubua;Patison Palee;Sakarat Na Lampang;Pasuk Mahakkanukrauh
    • Anatomy and Cell Biology
    • /
    • 제56권1호
    • /
    • pp.86-93
    • /
    • 2023
  • Age at death estimation has always been a crucial yet challenging part of identification process in forensic field. The use of human skeletons have long been explored using the principle of macro and micro-architecture change in correlation with increasing age. The clavicle is recommended as the best candidate for accurate age estimation because of its accessibility, time to maturation and minimal effect from weight. Our study applies pre-trained convolutional neural network in order to achieve the most accurate and cost effective age estimation model using clavicular bone. The total of 988 clavicles of Thai population with known age and sex were radiographed using Kodak 9000 Extra-oral Imaging System. The radiographs then went through preprocessing protocol which include region of interest selection and quality assessment. Additional samples were generated using generative adversarial network. The total clavicular images used in this study were 3,999 which were then separated into training and test set, and the test set were subsequently categorized into 7 age groups. GoogLeNet was modified at two layers and fine tuned the parameters. The highest validation accuracy was 89.02% but the test set achieved only 30% accuracy. Our results show that the use of medial clavicular radiographs has a potential in the field of age at death estimation, thus, further study is recommended.

Utility of intraoral scanner imaging for dental plaque detection

  • Chihiro Yoshiga;Kazuya Doi;Hiroshi Oue;Reiko Kobatake;Maiko Kawagoe;Hanako Umehara;Kazuhiro Tsuga
    • Imaging Science in Dentistry
    • /
    • 제54권1호
    • /
    • pp.43-48
    • /
    • 2024
  • Purpose: Oral hygiene, maintained through plaque control, helps prevent periodontal disease and dental caries. This study was conducted to examine the accuracy of plaque detection with an intraoral scanner(IOS) compared to images captured with an optical camera. Materials and Methods: To examine the effect of color tone, artificial tooth resin samples were stained red, blue, and green, after which images were acquired with a digital single-lens reflex (DSLR) camera and an IOS device. Stained surface ratios were then determined and compared. Additionally, the deviation rate of the IOS relative to the DSLR camera was computed for each color. In the clinical study, following plaque staining with red disclosing solution, the staining was captured by the DSLR and IOS devices, and the stained area on each image was measured. Results: The stained surface ratios did not differ significantly between DSLR and IOS images for any color group. Additionally, the deviation rate did not vary significantly across colors. In the clinical test, the stained plaque appeared slightly lighter in color, and the delineation of the stained areas less distinct, on the IOS compared to the DSLR images. However, the stained surface ratio was significantly higher in the IOS than in the DSLR group. Conclusion: When employing IOS with dental plaque staining, the impact of color was minimal, suggesting that the traditional red stain remains suitable for plaque detection. IOS images appeared relatively blurred and enlarged relative to the true state of the teeth, due to inferior sharpness compared to camera images.

근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도 (The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement)

  • 이병립;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성 (Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva)

  • 박문수;김영준
    • Journal of Oral Medicine and Pain
    • /
    • 제32권4호
    • /
    • pp.365-373
    • /
    • 2007
  • 구강건조증 환자에서 자주 발생하는 구강 연조직과 경조직의 손상은 구강건조증 환자의 삶의 질에 심각한 문제를 일으킨다. 타액선의 기능을 완전히 상실한 구강건조증 환자의 경우 인공타액은 유일한 처치법임에도 불구하고, 현재 통용되고 있는 인공타액은 환자들의 기대치에 비해 많이 부족한 실정이다. 본 연구는 CMC 용액과 인공타액의 점도와 습윤성을 비교함으로써 향후 이상적인 인공타액의 개발에 필요한 정보를 얻고자 시행되었다. CMC를 타액모방완충용액(simulated salivary buffer, SSB)과 증류수에 용해시켜 동물 mucin 용액을 완성한 후, 이를 인체 전타액, 인체 개별 타액선 타액, 그리고 CMC를 주성분으로 하는 인공타액인 Salivart 및 Moi-Stir와 비교 분석하였다. 점도는 cone-and-plate digital viscometer로 검체 당 6개의 전단율에서 측정하였고, 습윤성은 아크릴릭 레진과 Co-Cr alloy 표면 위에서의 접촉각 측정을 통해 평가하여 다음과 같은 결론을 얻었다. 1. CMC 용액의 점도는 CMC 농도에 비례하여 증가하였으며, 0.5% CMC 용액의 점도는 비자극성 전타액의 점도와 유사하였다. 반면에 CMC 용액의 접촉각은 점도와는 반대로 CMC 농도를 증가시킴에 따라 감소하였다. 2. 인체 타액의 점도는 전단율 증가에 따라 감소하는 non-Newtonian fluid의 특성을 나타내었다. 다양한 전단율에서의 평균 점도는 자극성 이하선 타액, 자극성 전타액, 비자극성 전타액, 자극성 악하선-설하선 타액의 순으로 증가하였다. 3. 인체 타액의 접촉각은 점도와는 반대로 자극성 이하선 타액, 자극성 전타액, 비자극성 전타액, 자극성 악하선-설하선 타액의 순으로 감소하였다. 4. 타액모방완충용액에 용해시킨 CMC를 가열하여 변성시킨 경우 점도가 감소하였다 (P < 0.01, 전단율 $90s^{-1}$). 5. 인체 타액의 아크릴릭 레진 표면에서의 접촉각은 인체 타액의 Co-Cr alloy 표면에서의 접촉각보다 유의하게 작은 것으로 나타났다 (P < 0.01). 6. 인체 타액의 아크릴릭 레진 표면에서의 접촉각은 CMC 용액의 아크릴릭 레진 표면에서의 접촉각보다 유의하게 작은 것으로 나타났다 (P < 0.01). 이번 연구에서 CMC 용액의 유동학적 성질을 객관적으로 확인할 수 있었으며, 이상의 결과를 종합하여 보면 CMC는 향후 효과적인 인공타액의 개발에 있어서도 중요한 역할을 수행 할 것으로 기대된다.

절삭 및 적층 가공법으로 제작한 임시 보철물 레진 블록과 재이 장용 자가중합 레진의 전단결합강도 비교 (Comparison of shear bond strength between various temporary prostheses resin blocks fabricated by subtractive and additive manufacturing methods bonded to self-curing reline resin)

  • 류효민;이진한
    • 대한치과보철학회지
    • /
    • 제61권3호
    • /
    • pp.189-197
    • /
    • 2023
  • 목적. 절삭 및 적층 가공 방식으로 제작한 임시 보철물 레진 블록과 재이장용 자가중합레진의 전단결합강도를 비교 평가하고자 하였다. 재료 및 방법. 레진 블록 시편의 제작방식에 따라 4개의 군으로 나누었고 subtractive manufacturing (SM), additive manufacturing stereolithography apparatus (AMS), additive manufacturing digital light processing (AMD), conventional self-curing (CON)의 방식으로 각 20개씩 레진 시편을 제작하였다. 제작 방식에 따른 레진 블록 시편과 재이장용 자가중합레진의 결합을 위해 시편의 표면에 실리콘 몰드를 이용하여 동일한 위치에 재이장 레진을 주입하여 중합하였다. 만능재료시험기를 이용하여 전단결합강도를 측정하였고 주사전자현미경으로 접착 계면의 파절 양상을 확인하였다. 실험군 간 비교를 위해 일원배치 분산분석과 사후 검정으로 Tukey test를 실시하였다(α = .05). 결과. 전단결합강도는 CON, SM, AMS, AMD군 순으로 높았다. CON군은 AMS군, AMD군과 유의한 차이가 있었고(P < .01) SM군과 유의한 차이가 없었다(P > .05). SM군은 AMD군과 유의한 차이가 있었고(P < .01) AMS군과 유의한 차이가 없었다(P > .05). AMS군은 AMD군과 유의한 차이가 있었다(P < .001). 파절 양상은 CON군, AMS군에서 혼합 파절이 높은 빈도로 나타났으며 SM군, AMD군에서 접착 파절이 높은 빈도로 나타났다. 결론. 절삭 및 적층 가공 방식으로 제작한 임시 보철물 레진 블록과 재이장용 자가중합 레진과의 전단결합강도에서 절삭 가공 방식(SM군)은 CON군보다 낮은 결합강도를 보였지만 유의한 차이를 보이지 않았다. 적층 가공 방식(AMS군, AMD군)은 CON군보다 유의하게 낮은 결합강도를 보였으며, AMD군이 가장 낮은 결합강도를 보였고 AMD군은 SM군과도 유의한 차이를 보였다.

임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구 (Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis)

  • 김지환;양승원;오남식
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.252-259
    • /
    • 2017
  • 목적: 본 연구의 목적은 지르코니아 전장관과 금전장관으로 수복된 임플란트 지지 고정성 보철물의 장착 후 초기 6개월간의 마모를 비교 분석하는 것이다. 연구 재료 및 방법: 2015년 1월부터 2016년 1월까지, 대구치 부위에 임플란트 지지 고정성 보철 수복을 요하는 환자를 대상으로 하였다. 총 47개에 대하여 임플란트 지지 고정성 보철물과 대합치에 대해 조사를 시행하였으며, 보철물 장착 1주 및 6개월 후 보철물 및 대합치를 인상채득 하여 교합면의 형태를 인기 하였다. 인상체를 스캔하여 보철물 및 대합치의 교합면 형태를 비교하여 마모 분석을 시행하였다. SPSS (Version 23.0; SPSS, IBM Corporation, Armonk, USA) 프로그램을 이용하여 정규성 분석 후 Mann-Whitney 분석을 시행하였다. 결과: 임플란트 지지 고정성 보철물에서 지르코니아 전장관과 금전장관 보철물의 6개월간 평균 수직거리 차의 중앙값은 각각 $50.84{\mu}m$, $42.84{\mu}m$로 통계적 유의차가 없었다(P > 0.05). 대합치가 자연치인 경우, 지르코니아 전장관 및 금전장관 보철물의 6개월간 평균 수직거리 차의 중앙값은 각각 $47.72{\mu}m$, $41.97{\mu}m$였으며, 대합치 법랑질의 평균 수직거리 차의 중앙값은 각각 $47.26{\mu}m$, $44.59{\mu}m$이었고, 통계적 유의차는 없었다(P > 0.05). 결론: 조사 기간이 짧았고, 실험군의 개수가 적었다는 단점이 있지만, 임플란트 지지 고정성 보철물 장착 후 초기 6개월간의 마모 비교에서 지르코니아 전장관과 금전장관은 유의한 차이가 없었고, 대합되는 자연치 법랑질의 마모도 유의한 차이는 없었다.