Automatic detection of the lung orientation in digital PA chest radiographs

  • Nahm, Kie-B.
    • Journal of the Optical Society of Korea
    • /
    • 제1권1호
    • /
    • pp.60-64
    • /
    • 1997
  • An image processing algorithm is presented that can identify the orientation as well as the left/right side (parity) of the digitized radiographs. The orientation was found by computing the mean square deviation between the sampled gray values along the center and their best-fit linear regression relations. The parity was determined by comparing the area difference between two thresholded images of the left and the right side around the heart, which is assumed to be around the center of the image. This method was tested with 86 images with their orientations intentionally rotated. The rotation was limited to multiples of 90 degrees, as this was the way the rotation is most likely to happen in the clinical environment. We obtained positive responses for 85 out of 86 images subject to the screening.

디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구 (The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography)

  • 신수인;김종일;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.223-228
    • /
    • 2008
  • 의학적으로 방사선을 사용 시 가장 중요한 점은 환자의 병을 진단 가능하되 피폭선량을 최소화시켜야 한다는 점이다. 진단용 X-선 중 장파장부분은 대부분 흡수에 관여하게 되어 환자의 피폭선량을 증가시키므로 불필요하다. 이러한 장파장영역을 제거하기 위한 방법으로 가장 효과적인 방법은 여과 판의 사용이다. 이에 부가여과가 없는 경우와 0.3mmCu filter 사용 시의 화질과 피부입사선량에 대해 실험을 해 보았다. ROC 신호용 지름 4mm, 두께 3mm의 아크릴 디스크를 chest phantom에 랜덤하게 위치시키면서 non filter 및 Cu filter시 각 각 20매씩 총 40매의 신호+잡음영상을 촬영하고, 또한 신호가 없는 영상(잡음만의 영상)을 각 각 20매씩 40매 촬영하여 총 80매의 영상을 준비한 후 5명의 방사선종사자가 판독 후 P(S/s), P(S/n) 구하여, ROC곡선을 그리고, 감도와 특이도 및 곡선하면적을 구해 평가하였다. 또한 AAPM(American Association of Physicists in Medicine by the American Institute of Physics)권고에 따른 ANSI chest phantom과 Contrast-detail phantom을 이용하여 non filter 또는 Cu filter사용 시 시각적으로 관찰 가능한 병소의 갯수를 파악하였으며, 또한 두 경우에서 피부입사선량을 측정하였다. 그 결과 Cu filter사용 시에 ROC곡선이 좌상방향에 위치하고, 감도, 곡선하면적 및 CD phantom 병소의 갯수에서 모두 좋은 결과를 나타내었다. 또한 피부입사선량은 감소가 되어 여러 측면에서 부가필터의 사용을 검토해 볼 필요가 있으리라 사료된다.

  • PDF

디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구 (A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System)

  • 김상현
    • 디지털융복합연구
    • /
    • 제13권9호
    • /
    • pp.351-359
    • /
    • 2015
  • 본 연구는 저에너지 방사선을 제거하기 위해 사용되는 구리 여과판의 디지털 방사선 장비에서 유용성을 분석하고자 선량, 화질평가의 융복합 연구를 실시하였다. 실험기간은 2015년 4월부터 6월까지 이었다. 관전압과 관전류 변화에 따른 구리 여과판 사용 전, 0.1, 0.2, 0.3 mm 의 선량을 평가하였다. 화질평가는 PSNR, MAE, MSE, CNR, SNR 정성적 평가로는 국가암검진 흉부 평가표의 해상, 대조도 평가 7문항을 이용하였다. 흡수선량은 16-88 % 정도 여과판 사용 전에 비해 측정치 낮아졌고, 관전압이 높아짐에 따라 격차가 작아짐을 알 수 있었다. PSNR은 30 dB이상으로 모두 의미 있는 수치였고, CNR, SNR은 여과판 미사용 시 우수했으나 정성적 평가에서는 항목마다 통계적 유의성이 달랐다. 0.1 mm 여과판에서는 폐혈관 관찰 부위에서 측정치가 높고, 0.3 mm도 밀도가 높고 공기가 많은 부위를 제외하고 통계적으로 유의하지 않았다. 구리 여과판은 좋은 선질과 디지털촬영 장비의 장점인 보정 능력 이용하여 더 적은 선량으로 화질을 향상 시킬 수 있다.

디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가 (Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR))

  • 최지안;황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제19권8호
    • /
    • pp.276-283
    • /
    • 2019
  • 본 연구는 자동노출제어장치(Automatic Exposure Control, AEC)와 수동노출 이용 시 입사표면선량(Entrance Surface Dose, ESD)과 Entropy를 분석하여 자동노출제어장치의 유용성에 대해 알아보고자 하였다. 실험방법은 Skull, Chest, Abdomen, Pelvis 부위에 대하여 란도팬텀(Rando Phantom)에 반도체 선량계를 위치시켜 선량을 측정하였고, 동시에 획득한 DICOM(Digital Imaging and Communications in Medicine) 파일을 Matlab으로 Entropy 분석을 하였다. 그 결과 자동노출제어장치 이용 시 모든 부위의 입사표면선량이 수동노출보다 낮았고 Entropy 수치는 높았으며, paired t-test는 p<0.05로 유의한 차이가 있음을 알 수 있었다. 결론적으로 자동노출제어장치의 사용은 X선 검사 시 발생할 수 있는 불필요한 방사선량과 정보의 손실량을 줄여서 피폭선량과 영상 화질의 최적화에 기여할 수 있는 유용한 방법이 될 수 있다.

디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성 (Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System)

  • 주영철;임청환;유인규;정홍량;이상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.135-142
    • /
    • 2016
  • 본 연구는 DR system에서 Chest PA 검사 시 일반적으로 적용되는 SID(180 cm)가 실제 심장크기 및 심흉비를 묘사하는데 적합한 거리인지 고찰해보고, 장비가 지닌 기하학적 원인이 영상에 미치는 영향을 알아보고자 한다. 자체 제작한 Chest phantom과 XGEO-GC80, INNOVISION-SH, UD150B-40 장비에 CXDI-40EG detector를 조합한 X선 발생장치를 이용하였다. 실험방법은 SID를 180 cm로 고정 후 OID를 0, 75, 83 mm로 변화시키며 영상을 획득하였다. 영상은 Centricity Radiography RA1000 PACS system에서 측정하였다. 통계프로그램은 SPSS(Version 22.0, SPSS, Chicago, IL, USA)를 사용하였고, p-value는 0.05 이하를 통계적으로 유의한 것으로 평가하였다. OID 0 mm에서 세 장비 모두 팬텀의 실제 CS, BS 보다 약 2.7~3.5 mm 정도 확대되었고, 계산된 확대율과 비교해 보았을 때 1.6~2.8% 확대되었다. OID 75 mm와 OID 83 mm에서는 6~8 mm 범위에서 CS와 BS가 확대되었다. 계산된 값과 비교했을 때 측정된 값은 6.1~7.9% 확대되었다. OID 변화에 따른 CS와 BS는 각 그룹간에 통계적으로 유의한 차이(p<0.05)를 보였으며, 사후분석에서는 OID 0 mm 그룹만 독립적인 그룹으로 나타났고, 75 mm와 83 mm는 동일한 그룹으로 분리되었다. 하지만 OID 변화에 따라서 통계적으로 유의한 차이가 없었으며(p >0.05), 사후 분석에서도 모두 같은 그룹으로 나타났다. DR system에서 Chest PA 검사 시 일반적으로 이용되고 있는 SID에서 검사하는 경우 심장의 크기는 실제 크기보다 6~8 mm크게 나타나며 이는 실제 이론적인 값보다 6.1~7.9% 확대되어 나타났다.

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교 (Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices)

  • 김상지;용환석;강은영;양제파;김정윤;윤영훈
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.138-146
    • /
    • 2024
  • 목적 카메라형 휴대형 X선 장치를 이용하여 촬영한 흉부 X선 사진의 영상품질을 기존 이동형 디지털 X선 장치로 촬영한 영상과 비교하여 임상에서 사용 가능한지 평가하고자 하였다. 대상과 방법 2020년 9월부터 2021년 5월까지 응급실에 내원한 환자 중 기관내 삽관, 중심정맥관, 비위관 등을 삽입한 86명의 환자를 대상으로 하였다. 환자들은 기구 삽입 전 기존 이동형 디지털 X선 장치, 기구 삽입 후 카메라형 휴대형 X선 장치를 이용하여 각각 흉부 영상을 촬영하였다. 두 명의 영상의학과 의사가 얻어진 두 영상을 삽입기구의 식별에 대하여 5점 척도, 전반적인 영상 품질에 대하여 20점 만점으로 평가하였다. 결과 카메라형 휴대형 X선 장치로 삽입한 기구의 식별에 대한 평가는 4.67 ± 0.71점이었다. 전반적인 영상품질에 대한 평가는 기존 이동형 디지털 X선 장치와 카메라형 휴대형 X선 장치가 각각 19.70 ± 0.72점과 15.02 ± 3.31점(p < 0.001)이었고, 호흡 및 움직임 관련 인공물, 기관 및 기관지, 폐혈관, 심장 뒤 혈관, 흉추 추간판 공간, 횡격막 하 혈관, 횡격막 관찰의 세부항목에서 카메라형 X선 장치의 점수가 통계적으로 유의하게 점수가 낮았다(횡격막 관찰 세부항목 p = 0.013, 그 외 세부항목 p < 0.001). 결론 카메라형 휴대형 X선 장치는 흉부X선 사진에서 삽입 기구의 평가를 목적으로 사용하는 것은 가능하나 영상의 품질 저하가 있으므로 일반적인 진단 목적의 사용에는 주의를 요한다.

디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구 (The Review of Exposure Index in Digital Radiography and Image Quality)

  • 양숙;한재복;최남길;이성길
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.29-36
    • /
    • 2013
  • CR과 DR 장비에서 팬텀을 이용하여 선량과 노출지수(exposure index, EI)의 변화를 관찰하고 처리된 영상에서 NSR(noise to signal ratio)과 CNR (contrast to noise ratio)을 측정하여 디지털 시스템에서 방사선량을 최적화하기 위한 인자들 간의 상관관계를 알아보고자 하였다. EI와 입사표면선량(entrance surface dose, ESD)는 CR과 DR 장비에서 모두 주어진 선량의 증가에 따라 비례하여 증가하였다. 적정범위 내 EI 산출시 CR의 경우 DR 보다 더 많은 선량이 요구되었으나 두 시스템에서 모두 EI 지표는 노출인자인 kVp, mAs의 증가에 대해 선형으로 비례하여 증가하였다. 특히, 검출기 효율이 우수한 DR 시스템에서는 선량 변화에 대해 더 안정된 감도를 나타내었고, 최소의 선량증가에도 영상의 유용한 대조도를 형성하여 화질의 향상에 쉽게 도달할 수 있었다. 이는 검출기 흡수선량과 밀접한 관련이 있는 EI 지표의 정확성을 예측 가능하게 하였다. EI의 물리적 특징과 영상평가를 위한 NSR 측정은 DR 시스템에서 CR 보다 더 낮은 NSR이 나타났으며 CR에서는 6 mAs이상의 관전류에서는 관전압의 값에 따른 영향이 상대적으로 적었다. 본 연구 결론은 디지털 시스템 검출기의 흡수선량 측정의 지표인 EI는 노출인자와 선형비례관계에 있었고 EI가 제조사에서 제공한 범위 내에 존재할 때 그 EI 지표가 우수할수록 최적의 영상화질을 얻을 수 있었다. 또한 디지털 방사선 영상 기술에서 EI의 물리적 특징의 활용은 실제 임상에서 영상의 화질향상에 도움을 주고 검출기의 품질관리를 통하여 환자의 불필요한 피폭선량을 줄이는 데 많은 기여를 할 수 있을 것이다.

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • 제48권1호
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.