• Title/Summary/Keyword: Digestion Method

Search Result 556, Processing Time 0.024 seconds

Comparison of Microwave with Conventional Wet-Digestion Methods for the Element Analysis of Plant and Compost (식물체 및 퇴비 성분 분석을 위한 마이크로웨이브 분해법과 기존 습식 분해법의 비교)

  • Nam, Jae-Jak;Cho, Nam-Jun;Jeong, Yee-Guen;Lee, Sang-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.3
    • /
    • pp.253-258
    • /
    • 1998
  • To verify the suitability of microwave digestion method for analyzing macro nutrients and metals. K, Ca, Mg, Cu, Zn, and Mn contents in plant and composts were investigated comparing with conventional wet digestion method. Because it takes short time to digest metal samples by using microwave method compared with conventional wet digestion method. Digestion time for metal samples was four to six hours long for wet digestion, while one hour long for microwave digestion. Determinant coefficients of Cu, Mn, Zn, Ca, K, and Mg contents between two analyzing methods were 0.99, 0.99, 0.94. 0.97, 0.98, and 0.91, respectively. In the case of Ca and K, microwave digestion method analyzed their contents relatively low compared with wet digestion method. Meanwhile, microwave digestion method analyzed the contents for Cu, Ma, and Zn relatively high compared with wet digestion method. This study results in that microwave digestion method could be an alternative to replacing conventional wet digestion method.

  • PDF

Pressure Cycling Technology-assisted Protein Digestion for Efficient Proteomic Analysis

  • Choi, Hyun-Su;Lee, Sang-Kwang;Kwon, Kyung-Hoon;Yoo, Jong-Shin;Ji, Kelly;Kim, Jin-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.599-604
    • /
    • 2011
  • In typical proteomic analysis, trypsin digestion is one of the most time-consuming steps. Conventional proteomic sample preparation methods use an overnight trypsin digestion method. In this study, we compared high-pressure cycling technology (PCT) during enzyme digestion for proteome analysis to the conventional method. We examined the effect of PCT on enzyme activity at temperatures of 25, 37, and $50^{\circ}C$. Although a fast digestion (1 h) was used for the standard protein mixture analysis, the PCT-assisted method with urea showed better results for protein sequence coverage and the number of peptides identified compared with the conventional method. There was no significant difference between temperatures for PCT-assisted digestion; however, we selected PCT-assisted digestion with urea at $25^{\circ}C$ as an optimized method for fast enzyme digestion, based on peptide carbamylation at these conditions. The optimized method was used for stem cell proteome analysis. We identified 233, 264 and 137 proteins using the conventional method with urea at $37^{\circ}C$ for 16h, the PCT-assisted digestion with urea at $25^{\circ}C$ for 1 h, and the non-PCT-assisted digestion with urea at $25^{\circ}C$ for 1 h, respectively. A comparison of these results suggests that PCT enhanced the enzyme digestion by permitting better access to cleavage sites on the proteins.

Determination of Heavy Metal in Polyurethane by New Digestion Method and ICP-AES (새로운 전처리 방법과 ICP-AES에 의한 폴리우레탄 중의 중금속 분석)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.363-367
    • /
    • 2004
  • A simple and convenient digestion method was developed for the determination of heavy metal in polyurethane sample using only nitric acid in open system without heating. This digestion method had prevented loss of volatile elements of Hg and As and reduced the pretreatment time for the sample digestion. The detection limit is lowered over 10 times than that of microwave digestion method. Recoveries in polyurethane material were 108% for As, 96 ~ 99% for Hg, 102 ~ 103% for Cr, 98 ~ 102% for Pb, 86 ~ 90% for Cd, and 90 ~ 93% for Cu.

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

Grain Processing on Feed Efficiency for Beef Production (비육용 곡물사료의 가공방법과 증체효율)

  • 김영길
    • Journal of Life Science
    • /
    • v.5 no.3
    • /
    • pp.126-136
    • /
    • 1995
  • The studies had been conducted to evaluate the grain processing effects for ruminants on starch digestion, body weight gain and feed efficiency since 1970. This research deals with experimental results on chemical structure, gelatinization, microbial starch digestion in rumen, intestinal starch digestion in rumen, roles of protozoa, intestinal starch digestion of bypass starch, limits to starch digestion in small intestine. The grain processing has different effects on digestion, weight gain and feed efficiency when different grain sources and contents is used, and the quality and quantity of roughage is different. The economical and efficient method of grain processing should be selected considering weight gain and feed efficiency enhancement than digestibility.

  • PDF

The controversial points and a remedy on evaluation of heavy metal contamination in standard method for examination of soil in Korea. (국내 토양오염 공정시험방법중 중금속 관련 오염평가의 문제점과 개선책)

  • 오창환;유연희;이평구;박성원;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.298-301
    • /
    • 2000
  • Heavy metals are extracted from stream sediments, roadside soils and sediments and soils and tailings from mining area using partial extraction, acid digestion and HF-digestion. Compared to amounts of heavy metals extracted using partial extraction, those extracted using acid digestion are higher by 2.0∼220.9 times in Cu, 2.4∼2806.1 times in Pb, 1.3∼121 times in Cd, 14.1∼1300885 times in Fe, 1.2∼271.5 times in Mn, 1.3∼372.5 times in Zn, 2.2∼1734.5 times in Cr. Although partial extraction, which extracts less amounts of heavy metals from soil compared to acid digestion, is used in domestic standard method for examination of soil, domestic soil standard for heavy metals in non-agricultural and industrial areas is higher than soil standard in foreign countries which use acid digestion, For improvement of the domestic standard method for assessment of soil, it is suggested to lower the domestic soil standard for heavy metals or to change pretreatment method for extracting heavy metals from partial extraction to acid digestion with modifying the soil standard.

  • PDF

Comparison of Anaerobic Digestion Efficiency with Different Temperature of Food Wastes (음식물류폐기물의 성상별 온도변화에 따른 혐기성소화 효율 비교 연구)

  • Hwang, Kwanghyun;Kim, Dongik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.332-339
    • /
    • 2019
  • A comparative study on the anaerobic digestion efficiency according to the temperature change was conducted considering the characteristics of domestic food wastes with high water content of about 80 % or more. The substrate was tested for anaerobic digestion efficiency in two substrates, a liquid component separated naturally from food waste and food waste itself. In the anaerobic digestion experiments, the digestion efficiency was the highest at $55^{\circ}C$ (thermophilic temperature). However, the digestion efficiency at $45^{\circ}C$(middle high temperature) was lower than that at $35^{\circ}C$(mesophilic temperature). The comparison of general food wastes anaerobic digestion requiring 30 days of hydraulic retention time to the liquid component indicated a stable digestion efficiency even after 15 days of hydraulic retention time.In the experiments conducted on food waste, the digestion efficiency at $55^{\circ}C$ was higher than that at $35^{\circ}C$. When the food waste, especially the liquid component originating from food waste, is treated by anaerobic digestion method, the mesophilic temperature and thermophilic temperature conditions are more favorable in the digestion efficiency than the middle high temperature ($45^{\circ}C$). However, when applying thermophilic or mesophilic temperature anaerobic digestion process operation in the field, the amount of energy input should be considered.

Sample Pretreatment for the Determination of Metal Impurities in Silicon Wafer (실리콘 웨이퍼 중의 금속 불순물 분석을 위한 시료 전처리)

  • Chung, H.Y.;Kim, Y. H.;Yoo, H.D.;Lee, S.H.
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.412-417
    • /
    • 1999
  • The analytical results obtained by microwave digestion and acid digestion methods for sample pretreatment to determine metal impurities in silicon wafer by inductively coupled plasma-mass spectrometry (ICP-MS) were compared. In order to decompose the silicon wafer, a mixed solution of $HNO_3$ and HF was added to the sample and the metal elements were determined after removing the silicon matrix by evaporating silicon in the form of Si-F. The recovery percentages of Ni,Cr and Fe were found to be 95∼106% for both microwave digestion and acid digestion methods. The recovery percentage of Cu obtained by the acid digestion method was higher than that obtained by the microwave digestion method. For Zn, however, the microwave digestion method gave better result than the acid digestion method. Fe was added to a silicon wafer using a spin coater. The concentration of Fe in this sample was determined by lCP-MS, and the same results were obtained in the two pretreatment methods.

  • PDF

Analysis of germanium in rock and sediment by ICP/MS after ammonium bifluoride(NH4HF2) digestion (이플루오린화 암모늄 시료분해 및 ICP/MS에 의한 암석 및 퇴적물 중 게르마늄 분석)

  • Eum, Chul Hun;Choi, Won Myung
    • Analytical Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.375-380
    • /
    • 2013
  • Ammonium biflouride ($NH_4HF_2$) digestion was studied for germanium analysis in rock and sediment by inductively coupled plasma mass spectrometry (ICP/MS). QLO-1 and SDO-1 are used for reference materials from USGS. Sediment, basalt and ball clay for GeoPT were chosen as real samples. The loss of germanium in open vessel digestion was well known which can be caused by easy transformation to volatile compounds. But ammonium bifluoride digestion could suppress loss of germanium in open vessel digestion. Germanium recovery was not influenced by hydrogen peroxide with ammonium bifluoride digestion. Furthermore, the new method was simple and rapid in germanium analysis by ICP/MS. MDL(method detection limit) was 0.015 ${\mu}g/g$ and germanium recovery was 106~128%.

Analysis of Asbestos Fiber in Lungs by Transmission Electron Microscopy According to the Digestion Method (회화방법에 따른 폐 내 석면섬유의 투과전자현미경 분석)

  • Han, Jeong Hee;Chung, Young Hyun;Yang, Jung Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.333-340
    • /
    • 2013
  • Objectives: This study was designed to establish an accurate analytical method for asbestos in a biological sample for determining occupational asbestos-related diseases and relief of the health effects of environmental asbestos. Methods: Biological samples were obtained from lungs of rats following intratracheal instillation of asbestos(Chrysotile, anthophyllite) and were prepared according to digestion method(Wet digestion, high temperature ashing, low temperature ashing). The samples were then analyzed for asbestos fibers using a transmission electron microscope equipped with an energy dispersive X-ray spectrometer. Results: Low temperature plasma ashing removed more of the organic components and reduced fiber loss compared to the wet digestion method, making specimens so prepared more suitable for transmission electron microsocpy. Conclusions: The low temperature ashing technique is the most accurate method for analyzing asbestos in biological samples.