• 제목/요약/키워드: Diffusion Plate

검색결과 231건 처리시간 0.023초

고속 원심분리장치의 확산판에 따른 상 분리효율에 관한 연구 (A Study on Three-Phase Separation Efficiency according to the Diffusion Plate of a High-Speed Centrifugal Separator)

  • 이춘만;정호인
    • 한국기계가공학회지
    • /
    • 제18권10호
    • /
    • pp.99-103
    • /
    • 2019
  • Recently, as the high-precision machinery industry has developed rapidly, peripheral equipment has been developed to improve machining efficiency. Peripheral equipment for machining includes cooling units, housings, oil separators, and much more. Oil, such as cleaning and cutting fluids, is used for machining. When waste oil is reused, the contamination of the workpieces and reduction in machining accuracy are generated by the waste oil, including sludge. Therefore, the development of an oil separator is necessary for efficiently separating oil, water, and sludge. The purpose of this study is to analyze the oil separation efficiency and flow characteristics of a high-speed centrifugal separator according to the rotation velocity and diffusion plate. The oil separation efficiency and flow characteristics were analyzed using hydrodynamic theory and computational fluid dynamics (CFD). The results of this study will be used as basic data for the development of a high-speed centrifugal separator.

PEM 연료전지용 가스확산층-탄소 복합재료 분리판 조합체 개발 (Development of GDL-carbon Composite Bipolar Plate Assemblies for PEMFC)

  • 임준우
    • Composites Research
    • /
    • 제34권6호
    • /
    • pp.406-411
    • /
    • 2021
  • PEM(양성자 교환막) 연료 전지는 부산물로 물 만을 생성하여 친환경 에너지원으로 각광받고 있다. 이러한 연료전지의 스택을 이루는 여러 부품들 중 연료전지의 효율을 결정짓는 분리판에 관한 연구가 활발히 진행되고 있다. 복합재료 분리판은 높은 강도와 강성 및 내식성을 갖지만 상대적으로 낮은 전기 전도도를 갖는 단점이 있다. 본 연구에서는 이러한 단점을 극복하고자 가스확산층(GDL)-복합재료 분리판 조합체를 개발하고 그 성능을 실험적으로 확인하였다. 선행 연구에서 개발된 흑연 포일 코팅법을 분리판과 GDL 간의 접촉 저항을 줄이기 위해 적용하였다. 또한, 스택 내의 전자 이동경로를 향상시키고 GDL과 분리판 사이의 접촉저항을 최소화하기 위하여 금속 박막을 이용하여 GDL-분리판 조합체를 제작하였다. 실험 결과 개발된 GDL-분리판 조합체는 기존의 복합재료 분리판과 비교하여 98% 낮은 전기저항을 갖는 것을 확인하였다.

고휘도 BLU 구현을 위한 도광판 패턴 설계 및 특성 평가 (Design and Fabrication of Pattern Structures of the Light Guide Plate for Enhanced Brightness of Backlight Unit)

  • 배창환;허경찬;전철규;류봉조;구경완
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.310-314
    • /
    • 2015
  • To improve the optical performance of the backlight unit with light guide plate(LGP), we investigated the effects of LGP patterns on the brightness and viewing angles properties of the backlight unit. We designed several patterns of LGP and calculated their optical properties by the optical simulation. The results reveal that the highest brightness and wide viewing angle was achieved with the extended-closed-polygon diffusion pattern and upper triangle prism pattern of the LGP.

p$^+$ Si 외팔보 구조를 이용한 광학 소자용 마이크로 구동기의 제작 (Fabrication of a Micro Actuator with p$^+$ Si Cantilevers for Optical Devices)

  • 박태규;양상식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권5호
    • /
    • pp.249-252
    • /
    • 2001
  • The paper represents the design and fabrication of an electrostatic micro actuator with $p^+$,/TEX> Si cantilevers. The micro actuator consists of a plate suspended by four $p^+$,/TEX> silicon cantilevers and an electrode on a glass substrate. The $p^+$,/TEX> Si structure is fabricated by the boron diffusion process and the anisotropic wet etch process. The cantilevers of the micro actuator curl down because of the residual stress gradient in $p^+$,/TEX> silicon. When the electrostatic forec is applied to the $p^+$,/TEX> cantilevers, the vertical displacement of the plate can be achieved. The deflection of the cantilever due to the residual stress gradient and the vertical displacement by electrostatic force were calculated. The displacement of the plate was measured with a laser displacement meter for various input voltages and frequencies. The feasibility of the proposed micro actuator for the applications to optical pickup devices or optical communication devices was confirmed by the experiments.

  • PDF

전산유체역학(CFD)를 활용한 정수공정에서 압력수 확산공정 진단 (Evaluation of Pressurized Water Diffusion in Water Treatment Process Using CFD)

  • 조영만;유수전;노재순;빈재훈;최광주;이광욱;이기봉;이정규
    • 대한환경공학회지
    • /
    • 제33권5호
    • /
    • pp.359-367
    • /
    • 2011
  • 압력수 확산공정은 정수공정에서 응집제나 염소용해수를 고압의 압력수로 분사하여 혼합하는 공정이다. 본 연구의 목적은 압력수 확산공정에 대한 전산유체역학적(Computational Fluid Dynamics) 진단을 통해 투입한 약품의 완전 혼합거리 및 혼합 거리를 줄이기 위한 확산판의 크기와 설치거리를 도출하는 것이다. 진단결과 2,200 mm 대형관에 $5kg/cm^2$ 압력수를 50mm, 100 mm 분사관으로 분사할 경우 혼합이 완료되는 혼합거리는 4D였다. 혼합거리를 줄이기 위해 분사관 전방에 확산판을 설치할 경우 분사관이 50 mm일 때 0.1D 직경의 확산판을 분사관 전방 0.2D 거리에 설치하면 혼합거리를 3D로 줄일 수있다. 그러나 분사관이 100 mm인 경우는 확산판의 크기와 설치 거리와는 상관없이 확산판이 없는 4D보다 확산거리를 줄일 수 없는 것으로 진단되었다. 따라서 2,200 mm 관에 압력수를 분사하는 경우는 50 mm 분사관을 설치하는 것이 100 mm보다 훨씬 효율적인 것으로 나타났다.

Diffusion Controlled Alkylation of Aromatic Compounds in Cation-Exchanged ZSM-5 Zeolites

  • Chon, Hak-Ze;Lee, Kyung-Yul;Park, Dong-Ho;Ahn, Byoung-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권6호
    • /
    • pp.625-628
    • /
    • 1991
  • Using uniform flat plate-like samples of ZSM-5 zeolites, diffusion coefficients were measured volumetrically for the diffusion of xylene, ethyltoluene and diethylbenzene by direct measurement of sorption rate. Toluene disproportionation over H(100)-, K(72)-and Cs(82)-ZSM-5 at 773 K and toluene methylation, toluene ethylation and ethylbenzene ethylation over Cs(75)-ZSM-5 at 623 K were carried out. The selective formation of para xylene during the toluene disproportionation, presumably due to the increased tortuosity over Cs-ZSM-5, could be explained by smaller diffusion coefficient in Cs-ZSM-5 than in K-and H-ZSM-5. The para selectivity increased in the order; toluene methylation < toluene ethylation < ethylbenzene ethylation. As the chain length of the alkyl substituent in dialkylbenzenes is increased, the para selectivity of the products was improved. It may be attributed to the differences in the ratios of diffusion coefficient of para products to that of ortho ones. Diffusion coefficient of m-xylene was about 1 order of magnitude smaller than that of o-xylene.

핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향 (Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

고분자 전해질 연료전지 금속분리판 316L 스테인리스강의 부식거동 및 기체확산층(GDL)과의 계면접촉저항 측정 (Corrosion Behaviors of 316L Stainless Steel Bipolar Plate of PEMFC and Measurements of Interfacial Contact Resistance(ICR) between Gas Diffusion Layer(GDL) and Bipolar Plate)

  • 오인환;이재봉
    • Corrosion Science and Technology
    • /
    • 제9권3호
    • /
    • pp.129-136
    • /
    • 2010
  • The corrosion behaviors of 316L stainless steel were investigated in simulated anodic and cathodic environments for proton exchange membrane fuel cell (PEMFC) by using electrochemical measurement techniques. Interfacial contact resistance(ICR) between the stainless steel and gas diffusion layer(GDL) was also measured. The possibility of 316L was evaluated as a substitute material for the graphite bipolar plate of PEMFC. The value of ICR decreased with an increase in compaction stress(20 N/$cm^2$~220 N/$cm^2$) showing the higher values than the required value in PEMFC condition. Although 316L was spontaneously passivated in simulated cathodic environment, its passive state was unstable in simulated anodic environment. Potentiostatic and electrochemical impedance spectroscopy (EIS) measurement results showed that the corrosion resistance in cathodic condition was higher and more stable than that in anodic condition. Field emission scanning electron microscopy (FE-SEM), and inductively coupled plasma(ICP) were used to analyze the surface morphology and the metal ion concentration in electrolytes.

2차유동이 평판후류의 난류구조에 미치는 영향 (Effects of Secondary Flow on the Turbulence Structure of a Flat Plate Wake)

  • 김형수;이준식;강신형
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1073-1084
    • /
    • 1999
  • The effects of secondary flow on the structure of a turbulent wake generated by a flat plate was investigated experimentally. The secondary flow was induced In a $90^{\circ}$ curved duct in which the flat plate wake generator was installed. The wake generator was installed in such a way that the wake velocity gradient exists in the span wise direction of the curved duct. Measurements were made in the plane containing the mean radius of curvature where pressure gradient and curvature effects were small compared with the secondary flow effect. All six components of the Reynolds stresses were measured in the curved duct. Turbulence intensities in the curved wake are higher than those in the straight wake due to an increase of the turbulent kinetic energy production by the secondary flow. In the inner wake region, shear stress and strain in the plane containing the velocity gradient of the wake show opposite signs with respect to each other, so that eddy viscosity Is negative in this region. This indicates that gradient-diffusion type turbulence models are not appropriate to simulate this type of flow.

Ni-PTFE 복합도금기술을 이용한 알칼리형 연료전지용 전극 제조 (Preparation of Electrode Using Ni-PTFE Composite Plating for Alkaline Fuel Cell)

  • 김재호;이영석
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.361-370
    • /
    • 2009
  • Ni-PTFE composite plated on graphite (C/Ni-PTFE) and PTFE (PTFE/Ni-PTFE) particles were prepared uniformly by electroless composite plating. The conductivity of C/Ni-PTFE particles was 280 S/m higher than 95 S/m of PTFE/Ni-PTFE particles at same composite plating condition (Ni:35~36 wt%, PTFE:8 wt%). The C/Ni-PTFE particles were formed into the C/Ni-PTFE plate using heat treatment at $350^{\circ}C$ under 10~$1000\;kg/cm^2$. The C/Ni-PTFE plate showed 1) high conductivity of $5.7\;{\times}\;10^4\;S/m$ due to the existence of graphite as conducting aid and the formation of 3-dimensional Ni network 2) good gas diffusion caused by various pore volumes (0.01~$100\;{\mu}m$) in the plate. The plate could be useful for an electrode in an alkaline fuel cell (AFC). The current density of C/Ni-PTFE electrode indicated $84\;mA/cm^2$ at 0.3V and it was 3.0 times higher than that of PTFE/Ni-PTFE electrode.