• 제목/요약/키워드: Diffuse optical imaging

검색결과 15건 처리시간 0.018초

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.

원자외선 영상/분광 측정기 광학설계 (OPTICAL DESIGN OF THE FAR ULTRAVIOLET IMAGING SPECTROGRAPH)

  • 유광선;선광일;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.359-371
    • /
    • 1998
  • 본 연구에서는 원자외선 영역($900~1750AA$)에서 오로라, 주/DIRKS 대기 광 관측 및 천문학적 관측을 동시에 수행하기 위한 FUVS(Far Ultraviolet Spectrograph)를 설계하고, 그 성능을 평가하였다. FUVS의 설계는 에돌이발(grating)의 광학적 특성과 비구면 광학을 충분히 고려하여 이루어졌으며, 분해능 계산을 위해 ray-trace 방법과 파면수차 계산에 의한 방법을 사용하여 설계의 검증을 시도하였다. 두 가지 방법에 의한 결과가 오차범위 안에서 일치하여 분석 방법에 큰 문제점이 없다는 것을 간접적으로 확인할 수 있었고, 전 영역에 걸쳐 대략 $2~5AA$의 분해능을 얻었다. 또한, FUVS의 수행 임무 중 가장 검출이 힘들 것으로 생각되는 고온의 성간 플라즈마에서 방출되는 선 방출의 검출 가능성을 타진하기 위하여 FUVS의 최소 검출가능 플럭스(MDF)를 계산하였다. 이 계산을 위하여 지금까지 알려진 반사물질, MCP 등의 특성을 충분히 고려하였으며, 선의 세기에 따라 하루에서 일주일에 걸친 관측을 통해 고온의 성간 플라즈마에서 방출되는 선 방출을 검출할 수 있다는 결론을 얻었다.

  • PDF

수직형 라이트파이프의 채광성능에 관한 예비평가 (Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System)

  • 신혜미;박훈;김정태
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계 (Optical System Design of Compact Head-Up Display(HUD) using Micro Display)

  • 한동진;김현희
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.6227-6235
    • /
    • 2015
  • HUD는 투시형 정보 전시장치로서 최근에 마이크로 디스플레이와 LED 기술의 발달로 소형화가 이루어져 점차 응용분야를 넓혀가고 있다. 본 논문에서는 마이크로 디스플레이 장치인 DLP를 이용하여 영상 전시영역 5인치 급의 양안 관측용 소형 헤드업 디스플레이(HUD) 광학계를 설계하였다. 소형 경량화된 HUD를 설계하기 위하여 광학계의 각 설계요소를 분석하였고 DLP, 프로젝젼 광학계 및 오목렌즈형 영상결합기의 특성들과 설계방식을 살펴보았다. 각 광학계의 연결구조 분석을 통하여 세부 설계사양을 설정하고 광학계를 상세 설계하였다. 프로젝션 광학계와 오목렌즈형 영상결합기 사이에 백색 확산 반사체를 넣어 접은 형태로 구성하여 광학계를 각각 독립적으로 설계하였다. 투사 영상의 전시거리는 약 2m ~ 무한대 까지 조정이 가능하고 관측거리는 1m로 설정하였다. 해상도는 HD($1,280{\times}720$ 화소) 급으로 1 ~ 2화소 까지 인식이 가능하여 각종 문자, 기호를 판독할 수 있다. 또한, 컬러영상 구현이 가능하여 네비게이션 지도, 주간카메라 영상 및 열상카메라 영상 등을 전시할 수 있다.

과학위성 1호 탑재체 원자외선 분광기의 OVI 방출선 검출 한계 (OVI EMISSION LINE DETECTION LIMIT OF FAR-ULTAVIOLET IMAGING SPECTROGRAPH)

  • 선광일;유광선;육인수;박장현;남욱원;한원용;선종호;민경옥
    • Journal of Astronomy and Space Sciences
    • /
    • 제17권1호
    • /
    • pp.77-86
    • /
    • 2000
  • $10^{4.5}K$$10^{6}K$ 사이의 온도를 갖는 고온기체가 주로 복사열에 의해 냉각될 때 900 ${\AA}$에서 1 1,200 ${\AA}$사이의 원자외선 영역에서 OVI 이중선$(\lambda\lambda1032,\lambda\lambda1038)$을 가장 강하게 방출하게 된다. 은하 전체에 걸쳐 넓게 분포하는 원자외선 방출선을 검출하려는 시도가 그동안 몇 번 있어왔으나 극히 제한된 일부 시선방향으로만 OVI 방출선이 관측되었을 뿐 관측 자료가 극히 미비한 상태이다. 또한 지구 대기로부터 방출되는 여러가지 밝은 대기광들로 인해 OVI 방출선의 관측이 영향을 받게 된다. 대기광중 OVI 방출선에 가장 가까이에 위치하는 HI 1025 ${\AA}$과 01 1027 ${\AA}$ 두 line이 약 $10^{5.5}K$ photons/s/$cm^2$/sr의 강도 (intensity)로서 가장 큰 영향을 미친다. 본 연구에서 는 온테카를로 모의실험과 $\chi^2$ 검사 기법 등을 통하여 과학위성 1호에 탑재 예정인 원자외선 분광기로부터 OVI 이중선의 검출 가능성을 연구하였다. 또한 기존의 원자외선 관측 결과 및 이론으로부터 예상되는 결과와 비교하였으며 OVI 분석 결과를 실제 광학부 제작에 필요한 오차 허용 한계 (tolerance limit)를 결정짓는 중요한 변수로 사용하도록 하였다.

  • PDF