• Title/Summary/Keyword: Difficult-to-Material

Search Result 1,852, Processing Time 0.027 seconds

The Evaluation of the Packaging Properties and Recyclability with Modified Acrylic Emulsion for Flexible Food Paper Coating (유연 종이 식품 포장재의 개질 아크릴 에멀젼 코팅 특성 및 재활용성 평가)

  • Myungho Lee;In Seok Cho;Dong Cheol Lee;Youn Suk Lee
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.3
    • /
    • pp.153-161
    • /
    • 2023
  • The worldwide effects of COVID-19 have led to a surge in online shopping and contactless services. The consumption pattern has caused the issues such as the environmental pollution together with the increase of plastic waste. Reducing the reliance on the petroleum based plastic use for the package and replacing it with environmentally friendly material are the simple ways in order to solve those problems. Paper is an eco-friendly product with high recyclability as the food packaging materials but has still poor barrier properties. A barrier coating on surface of the paper can be achieved with the proper packaging materials featuring water, gas and grease barrier. Polyethylene (PE) or polypropylene (PP) coatings which are generally laminated or coated to paper are widely used in food packaging applications to protect products from moisture and provide water or grease resistance. However, recycling of packaging containing PE or PP matrix is limited and costly because those films are difficult to degrade in the environment. This study investigated the recyclability of modified acrylic emulsion coating papers compared to PE and PP polymer matrixes as well as their mechanical and gas barrier properties. The results showed that PE or modified acrylic emulsion coated papers had better mechanical properties compared to the uncoated paper as a control. PE or PP coating papers showed strong oil resistance property, achieving a kit rating of 12. Those papers also had a significantly higher percentage of screen reject during the recycling process than modified acrylic coated paper which had a screen rejection rate of 6.25%. In addition an uncoated paper had similar value of a screen rejection rate. It may suggest that modified acrylic emulsion coating paper can be more easily recycled than PE or PP coating papers. The overall results of the study found that modified acrylic emulsion coating paper would be a viable alternative to suggest a possible solution to an environmental problem as well as enhancing the weak mechanical and poor gas barrier properties of the paper against moisture.

Oral health status and treatment need of institutionalized elderly patients (노인요양시설에 있는 노인환자의 구강실태 및 치료수요도)

  • Yang, Soon-Bong;Moon, Hong-Suk;Han, Dong-Hoo;Lee, Ho-Yong;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.455-469
    • /
    • 2008
  • Statement of problems: In the area of dental care, the institutionalized elderly have placed the most vulnerable state, and we cannot find their subjective need of dental treatment because of the physical and mental disabilities, But we have no basic investigation of their oral health conditions. Purpose: The aims of the current study were to investigate the oral health status of institutionalized elderly patients who are in the least benefited side of dental service, and to analyze their dental treatment needs. Material and methods: The survey of the oral status was carried out on 758 institutionalized elderly, and 212 elderly who was more than 65 years old from D dental office, and it was based on the Guidelines of Oral Health Research of year 2000 in Republic of Korea. Results and conclusion: The DMFT index of the institutionalized elderly appeared higher than that of the same ages in control group, and it increased with age. The number of residual teeth of the institutionalized elderly appeared lower than that of the same ages in control group, and it decreased with age (P < .05). The number of fixed partial denture in institutionalized elderly was lower than that of the same ages in control group (P < .05). The percentage wearing removable partial denture was not significant between the elderly in institutions and the control group, and was not different according to age between the two groups. The percentage of institutionalized elderly wearing complete denture appeared lower than that of the same ages in control group, and it increased with age. The percentage of institutionalized elderly needing complete denture was higher than that of control group, and the percentage of elderly needing complete denture on the maxilla was higher than that of the mandible. 16.35% of the institutionalized elderly was living without denture in spite of their fully edentulous state. The need for complete denture increased rapidly with age. The number of valued teeth and dental prostheses in shortened dental arch concept and number of occluding pairs of teeth of institutionalized elderly were lower than that of the control group (P < .05). In institutionalized elderly, the number of residual teeth, the number of fixed partial dentures, and the percentage wearing removable partial dentures were higher in the mandible, and the percentage wearing complete dentures was higher in the maxilla (P < .05). The rate of institutionalized elderly needing prosthodontic treatment appeared to be 67.82%, where the number of occluding pairs of teeth was less than 10. When it is difficult to evaluate the subjective need of dental treatment as with the institutionalized elderly, estimation using the number of occluding pairs of teeth can be a useful indicator that can project treatment needs. For the oral health care of institutionalized elderly, it is essential to increase the awareness of nurses and caregivers who take care of them, about the importance of the oral health. Since the average life span and number of residual teeth are increasing gradually, the welfare policy should be changed to implementing regular dental examinations, preservative treatment forms and oral health control of dentulous patients where the traveling-treatment system and visit system are supplemented. And principles should be set that the present denture project of edentulous patients should be done by specialists who'll also be responsible for postmanagement. Through this research of institutionalized elderly, the oral health status which is worsened by aging could be confirmed. And the interest and positive participation of dental society on the elderly should come first in order to solve the rising treatment needs of the elderly patients.

Establishment of Herbicide Screening Methods for Reed (Phragmites communis Trin.) Control - I. Propagation of Reed (갈대(Reed, Phragmites communis Trin.)의 방제를 위한 제초제 스크리닝방법의 확립 - I. 갈대의 육묘)

  • Hwang, I.T.;Choi, J.S.;Lee, H.J.;Hong, K.S.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.16 no.1
    • /
    • pp.21-27
    • /
    • 1996
  • This experiment was conducted to find out an effective propagation method for reed(Phragmites communis Trin.), ensuring a continuous herbicide screening for reed control. Reed propagation methods were compared under a greenhouse condition using tour different materials; seeds, rhizomes, depressed stolons of P. japonica Steud., and stem cuttings. Although reed seeds were easy to harvest and store, their germination rate(${\leq}$5%) was very low and seedling growth from the seeds was slow. Rhizomes were difficult to harvest and their harvest time was limited from November to March. Furthermore, reed propagation using rhizomes had problems of a relatively low germination rate(46%), no uniformity in size and shape, individual differences at the early stage of growth, and difficulties in material storage. Rate of reed growth from rhizomes was higher in commercial soil mix(Boo Nong soil) than in sand or in sand+upland soil(1:1). Depressed stolons of P. japonica had a moderate germination rate(65%) and were relatively easy to harvest. However, their harvest time was limited only from August to September. Propagation method using stem cuttings had several advantages over the above methods using other materials. Reed plants could uniformly be propagated from the stem cuttings with a relatively high germination rate(75%). Stem cuttings of central nodes showed a higher germination rate compared to those of upper or lower nodes. Stem cuttings from the field should be used immediately after harvest, since their germination rate decreased rapidly when they were stored under a wet- or a dry-refrigerated condition. Furthermore, the germination of stem cuttings tended to decrease when they were collected from the field after August. This indicates that there is a limitation of harvest time for stem cuttings. However, a year-round propagation of reed using stem cuttings is possible if parent plants are grown in a greenhouse, and thus herbicide screening for reed control could continuously be performed.

  • PDF

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

Estimation of Uranium Particle Concentration in the Korean Peninsula Caused by North Korea's Uranium Enrichment Facility (북한 우라늄 농축시설로 인한 한반도에서의 공기중 우라늄 입자 농도 예측)

  • Kwak, Sung-Woo;Kang, Han-Byeol;Shin, Jung-Ki;Lee, Junghyun
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.127-133
    • /
    • 2014
  • North Korea's uranium enrichment facility is a matter of international concern. It is of particular alarming to South Korea with regard to the security and safety of the country. This situation requires continuous monitoring of the DPRK and emergency preparedness on the part of the ROK. To assess the detectability of an undeclared uranium enrichment plant in North Korea, uranium concentrations in the air at both a short and a long distance from the enrichment facility were estimated. $UF_6$ source terms were determined by using existing information on North Korean facility and data from the operation experience of enrichment plants from other countries. Using the calculated source terms, two atmospheric dispersion models (Gaussian Plume Model and HYSPLIT models) and meteorological data were used to estimate the uranium particle concentrations from the Yongbyon enrichment facility. A maximum uranium concentration and its location are dependent upon the meteorological conditions and the height of the UF6 release point. This study showed that the maximum uranium concentration around the enrichment facility was about $1.0{\times}10^{-7}g{\cdot}m^{-3}$. The location of the maximum concentration was within about 0.4 km of the facility. It has been assumed that the uranium sample of about a few micrograms (${\mu}g$) could be obtained; and that few micrograms of uranium can be easily measured with current measurement instruments. On the contrary, a uranium concentration at a distance of more than 100 kilometers from the enrichment facility was estimated to be about $1.0{\times}10^{-13}{\sim}1.0{\times}10^{-15}g{\cdot}m^{-3}$, which is less than back-ground level. Therefore, based on the results of our paper, an air sample taken within the vicinity of the Yongbyon enrichment facility could be used to determine as to whether or not North Korea is carrying out an undeclared nuclear program. However, the air samples taken at a longer distance of a few hundred kilometers would prove difficult in detecting a clandestine nuclear activities.

Routine Off-pump Total Arterial Coronary Revascularization (심폐바이때스 없이 시행된 동맥 도관만를 이용한 관상동맥 완전 재관혈화)

  • Lee, Jae-Won;Park, Nam-Hee;Kang, Seong-Sik;Choo, Suk-Jung;Park, Seung-Jung;Park, Seung-Wook;Hong, Myeong-Ki;Song, Hyun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.309-315
    • /
    • 2003
  • Background: To avoid the adverse effects of cardiopulmonary bypass and to overcome late vein graft failure we routinely peformed off-pump total arterial coronary revascularization. Material and Method: From July 2000 to August 2001, 104 consecutive patients underwent first elective off-pump total arterial coronary revascularization. Both internal mammary, radial and gastroepiploic arteries were used. Sequential and composite grafts were used to achieve complete revascularization. Perioperative adverse events and postoperative angiograms were analyzed. Result: A total of 252 arterial conduits were used with an average of 2.47 grafts per patient. A total of 326 distal anastomosis were performed with a mean of 3.13 distal anastomosis per patient. Cross over to on-pump occurred in seven patients (6.7%). Of these 4 were due to unstable hemodynamics during lateral or posterior wall stabilization as a result of cardiomegaly and 3 were due to uncontrolled bleeding during dissection of diffusely dimunitive deeply placed intramyocardial coronary arteries. There were no opeartive deaths. Two cases of perioperative myocardial infarction and transient neurologic complications occurred, respectively. Of the 312 distal anastomoses, 308 (98.7%) were compatible with Fitz-Gibboll A or B patency grading. Conclusion: Off-pump total arterial coronary revascularization was technically feasible in most elective cases with satisfactory early results. However, on-pump coronary bypass surgery should be considered in difficult circumstances, such as cardiomegaly or unfavorable anatomy of the target coronary artery.

Parents' Perception and Satisfaction of School Food Materials and Supplier -Performance in Mokpo, Korea- (학교급식 식재료 및 공급업체에 대한 학부모들의 인식 및 만족도 -목포지역 중심으로-)

  • Lee, Seok-In;Kang, Pyong-Yon;Jung, Hyun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.11
    • /
    • pp.1741-1749
    • /
    • 2015
  • The purpose of this study was to investigate parents' perception and satisfaction of school food materials and supplier performance in Mokpo. To achieve these research objectives, a questionnaire was distributed to parents at 66 schools, and a total of 589 were used in the final analysis. The results of this study were as follows. First, satisfaction of school foodservice, showed the following scores: overall was 3.75, quality of food materials was 3.84, reliability of food suppliers was 3.80, education was 3.53, and information was 3.50. Second, 38.5% of parents participated in receiving school materials. Exactly 80.6% of parents showed intentions to participate. The most difficult thing for receiving materials was comparing quality of food materials (46.3%). Third, the most important factor cited for school food supplier was quality (62.3%) and sanitation and safety (24.1%). Forth, most parents were positive about the possibility of replacing foods used at school with environment friendly products. Local foods were cited for use in school foodservice (92.2%). The reasons were good quality (39.9%) and contribution to the local community (28.5%). In conclusion, parent's perception of school foodservice should increase to improve food material quality of school foodservice. Institutions for certifying are needed to offer high quality food materials at school foodservice and improved communication and education tool between the school and parents.

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.

Occlusive Complications after Lower Limb Arterial Bypass Surgery (하지동맥 재건술 후 폐쇄성 합병증에 대한 임상적 고찰)

  • Kim Jong Won;Chung Sung Woon
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.152-156
    • /
    • 2005
  • Background: Occlusive complications after arterial revascularization are difficult to treat and have high recurrence rate. This study was performed to establish an effective treatment modality and to evaluate the factors affecting the occlusive complications by analysis of clinical data. Material and Method: During the period of 5 years. 33 patients (55 reoperations) were studied at the Department of Thoracic and Cardiovascular Surgery, Pusan National University Hospital following 173 arterial revascularization surgeries. The clinical characteristics, operating methods, the time intervals of reoperation, used graft, and the results of treatment were evaluated retrospectively. Result: All the patients were men except one and the mean age was 63.5 years old. The mean time internal from first operation to reoperation was 11.9 months. The cause of arterial occlusive diseases were 28 atherosclerosis and 5 Burger's diseases, Associated diseases were Hypertension $(57.6\%)$, Diabetes mellitus $(33.3\%)$, heart failure $(18.2\%)$, and so on. The mean rate of reoperation was 1.67 times and the most common type of first operation was femoro-popliteal bypass grafting $(57.6\%)$. The graft that used revascularization surgery were 25 cases of PTFE and 6 case were Dacron. There was no statistical difference between two groups. The kinds of reoperations were thrombectomy in 20 cases, angioplasty 18 cases, re-bypass surgery in 13 cases, and lumbar sympathectomy in 4 cases. The results of reoperation were 15 cases of functional recovery, 7 cases of limb salvage, 5 cases of above-knee amputation. 3 cases of below-knee amputation and 3 deaths. Conclusion: The main cause of occlusive complications are occlusion of inflow or outflow artery. Treatments were different according to the first operation methods and graft used. The most frequent time of reoperation was within one year after the first operation. We believe that graft surveillance especially during the first year is very important factor in observing the patient. We can look forward to improving limb salvage rate to perform additional treatment such as radiological interventions and lumbar sympathectomy.

A study on quantification of α-quartz, cristobalite, kaolinite mixture in respirable dust using by FTIR (FTIR를 이용한 호흡성 분진중 α-quartz, cristobalite, kaolinite 혼합물 정량 분석 연구)

  • Eun Cheol Choi;Seung Ho Lee
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.315-323
    • /
    • 2023
  • This study is to quantify α-quartz, cristobalite and kaolinite using by FTIR in respirable dust generated in the mining workplace. Various minerals in mines can interfere with peaks when quantifying respirable crystalline silica by FTIR. Therefore, for accurate quantification, it is necessary to remove interfering substances or correct the peaks that cause interference. To confirm the peaks occurring in α-quartz, cristobalite and kaolinite, each standard material was diluted with KBr and scanned in the range of 400 cm-1 to 4000 cm-1 using by FTIR. As a result of scanning the analytes, it was decided to use the peaks of 797.66 cm-1 and 695.25 cm-1 for α-quartz, 621.58 cm-1 for cristobalite, and 3696.47 cm-1 for kaolinite. When the above materials are mixed, interference occurs at the peak for quantification, which is corrected by the calculation formula. The analysis of the mixture of α-quartz and cristobalite shows the average bias (%) of 2.64 (corrected) at α-quartz (797.66 cm-1), 5.61 (uncorrected) at α-quartz (695.25 cm-1) and 1.51 (uncorrected) at cristobalite (621.58 cm-1). The analysis of the mixture of α-quartz and kaolinite shows the average bias(%) of 1.79(corrected) at α-quartz (797.66 cm-1), 3.92 (corrected) at α-quartz (695.25 cm-1) and 2.58 (uncorrected) at kaolinite (3696.47 cm-1). The analysis of the mixture of cristobalite and kaolinite shows the average bias (%) of 2.15 (corrected) at cristobalite (621.58 cm-1), 4.32 (uncorrected) at kaolinite (3696.47 cm-1). The analysis of the mixture of αquartz and cristobalite and kaolinite shows the average bias (%) of 1.93(corrected) at α-quartz (797.66 cm-1), 6.47 (corrected) at α-quartz (695.25 cm-1) and 1.77 (corrected) at cristobalite (621.58 cm-1) and 2.61 (uncorrected) at kaolinite (3696.47 cm-1). The experimental results showed that the deviation caused by peak interference by two or three substances could be corrected to less than 6 % of the average deviation. This study showed the possibility of correcting and quantifying when various interfering substances that are difficult to remove are mixed.