• Title/Summary/Keyword: Differential uniformity

Search Result 35, Processing Time 0.031 seconds

Differential Driving of Inverter for High Uniformity LCD TV Backlight (LCD TV용 고균일도 백라이트 구동을 위한 Differential Driving 인버터)

  • Chun Young Tea;Lim Sungkyoo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.37-41
    • /
    • 2004
  • Parallel combination of cold chathode fluorescent lamps (CCFL) are widely used as the light sources of LCD TV backlight. Brightness uniformity is safisfied by using one transformer per one CCFL. Instead of using one transformer per oneCCFL, one transformer is used to drive 8 CCFLs by using differential driving method. A differential driving inverter with two transformers is developed to drive 16 CCFLs of 26' backlight for LCD TV. The brightness uniformity of $88\%$ was obtained by driving 26' backlight with the developed differential driving inverter successfully.

  • PDF

How to Generate Lightweight S-Boxes by Using AND Gate Accumulation (AND 연산자 축적을 통한 경량 S-boxes 생성방법)

  • Jeon, Yongjin;Kim, Jongsung
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.32 no.3
    • /
    • pp.465-475
    • /
    • 2022
  • Due to the impact of COVID-19, people are paying attention to convenience and health, and the use of IoT devices to help them is increasing. In order to embed a lightweight security element in IoT devices that need to handle sensitive information even with limited resources, the development of a lightweight S-box is essential. Until 2021, it was common to develop a lightweight 4-bit S-box by a heuristic method, and to develop an extended structure or repeat the same operation for a larger size lightweight S-box. However, in January 2022, a paper that proposed a heuristic algorithm to find an 8-bit S-box with better differential uniformity and linearity than the S-box generated with an MISTY extended structure, although non-bijective, was published [1]. The heuristic algorithm proposed in this paper generates an S-box by adding AND operations one by one. Whenever an AND operation is added, they use a method that pre-removes the S-box for which the calculated differential uniformity does not reach the desired criterion. In this paper, we improve the performance of this heuristic algorithm. By increasing the amount of pre-removal using not only differential uniformity but also other differential property, and adding a process of calculating linearity for pre-removing, it is possible to satisfy not only differential security but also linear security.

Phantom Image Evaluations Depending on the Quality Control-Uniformity of Brain Perfusion SPECT Scanner (뇌 관류 SPECT 스캐너의 정도관리-균일도에 따른 팬텀 영상 평가)

  • Jung-Soo, Kim;Hyun-Jin, Yang;Joon, Kim;Chan-Rok, Park
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.29-36
    • /
    • 2023
  • To have highly reliable diagnostic performance of it, this study comparatively analyzed spatial resolution of SPECT images and interrelationship depending on the changes of system uniformity of ga㎜a camera through phantom analysis. This study chose 6 kinds of results from quality control (uniformity) of triple head SPECT scanner operated in an university hospital in Seoul for six months. Then, study measured spatial resolutions (FWHM) of the images restructured by injecting radiopharmaceuticals to Jaszczak phantom, and doing SPECT scanning under the same conditions as clinical ones using the analytical program (image J). Quality controls performed by the experimental institution showed that differential uniformity of UFOV ranged from 2.76% to 7.61% (4.46±2.07), and integral uniformity of UFOV ranged from 1.98% to 5.42% (3.01±1.43). Meanwhile, Quantitative analysis evaluations of phantom images depending on the changes of uniformity of SPECT scanner detector showed that as the uniformity values of UFOV and CFOV decreased, FWHM values of phantom images decreased from 8.5 ㎜ to 5.8 ㎜. That is, it was quantitatively identified that the higher uniformity of detector is, the better spatial resolution of images gets (P<0.05). It is very important to perform continuous and consistent quality control of the nuclear medicinal system, and users should be clearly conscious of it.

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

Improved Differential-Linear Cryptanalysis Using DLCT (DLCT를 활용한 향상된 차분선형 분석)

  • Kim, Hyunwoo;Kim, Seonggyeom;Hong, Deukjo;Sung, Jaechul;Hong, Seokhie
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.6
    • /
    • pp.1379-1392
    • /
    • 2018
  • The complexity of the differential-linear cryptanalysis is strongly influenced by the probability of the differential-linear characteristic computed under the assumption of round independence, linear approximation independence, and uniformity for the trail that does not satisfy differential trail. Therefore, computing the exact probability of the differential-linear characteristic is a very important issue related to the validity of the attack. In this paper, we propose a new concept called DLCT(Differential-Linear Connectivity Table) for the differential-linear cryptanalysis. Additionally, we propose an improved probability computation technique of differential-linear characteristic by applying DLCT. By doing so, we were able to weaken linear approximation independence assumption. We reanalyzed the previous results by applying DLCT to DES and SERPENT. The probability of 7-round differential-linear characteristic of DES is $1/2+2^{-5.81}$, the probability of 9-round differential-linear characteristic of SERPENT is computed again to $1/2+2^{-57.9}$, and data complexity required for the attack is reduced by $2^{0.2}$ and $2^{2.2}$ times, respectively.

A differential Uniformity of Permutations u$^{x}$ in GF(2$^{n}$ ) (갈로아체 멱승 순환 함수의 입출력 변환의 균등성)

  • 김희진;김종덕;손중제;임종인
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 1997.11a
    • /
    • pp.189-195
    • /
    • 1997
  • S-box의 암호학적 성질이 블록 암호 알고리즘의 안정성을 좌우한다. 여기서 말하는 암호학적 성질이란 선형 공격법에 안전한 높은 비선형성과 입출력 변화공격법에 안전한 입출력 변환의 낮은 균등성을 말한다. 본 논문에서는 갈로아 체의 원시원을 밑으로 하는 멱승 순환 함수를 이용한 S-box의 입출력 변환의 균등성에 관하여 서술한다.

  • PDF

A commercial-ready, high resolution AMOLED mobile display with amorphous silicon backplane

  • Church, Corbin;Chaji, Reza;Alexander, Stefan;Nathan, Arokia
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1001-1004
    • /
    • 2008
  • An advanced backplane circuit technology for AMOLED using amorphous silicon TFTs with commercial level reliability, uniformity and lifetime was recently integrated into a prototype device. Differential aging of T98>100 hrs at 200 cd/m2 brightness and >10,000hrs lifetime is demonstrated. A 2.2" QVGA ($240{\times}320$) prototype has been developed and shown having the above-mentioned high performance.

  • PDF

Can Ultrasound be Used to Differentiate Tubular Adenomas of Breast from Fibroadenomas or Carcinoma?

  • Fu, Ying;Miao, Li-Ying;Ge, Hui-Yu;Mei, Fang;Wang, Jin-Rui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.3
    • /
    • pp.1269-1274
    • /
    • 2014
  • Breast tubular adenomas are rare benign breast tumors and detailed descriptions of their sonographic appearance are necessary for differential diagnosis from fibroadenomas or breast cancers. This study investigated twenty-one histology-proved tubular adenomas in 17 patients and also included 48 fibroadenomas in 35 patients as a control group. There was no significant difference between the two groups with clinical presentation, which was age, tumor location, tumor number (p>0.05). Statistic analysis showed three significant factors in the differential diagnosis of tubular adenomas and fibroadenomas, including macro-lobulation (p=0.01), "tiny branch like" patterns (p=0.001) and vascularity (p=0.02). Other ultrasonographic features such as echogenicity, border, uniformity of echotexture, posterior acoustic enhancement, lateral wall shadowing were of no clinical significance (p>0.05). Calcifications were seen in three tubular adenomas which were different from those of carcinomas. Although tubular adenomas have some typical characteristics on sonography, surgery and core needle biopsy are still needed for complex cases to exclude progress to malignancy.

A Study on Visual Comfort for Compound Lighting Control Method of Applied Daylighting (자연채광의 응용에 의한 합성조명방식의 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Jeon, Yong-Han;Han, Sang-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.199-206
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, the two variables were used in this study. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.