• Title/Summary/Keyword: Differential Apparatus

Search Result 58, Processing Time 0.028 seconds

Magnetic Field Measuring System by using Loop-type Sensor (루우프형 센서를 이용한 자장측정계)

  • Lee, Bok-Hee;Kil, Gyung-Suk;Park, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.14-21
    • /
    • 1995
  • This paper deals with the active magnetic field measuring system which can measure the time-varying magnetic fields generated by power installations and lightning discharges. The magnetic field measuring system consists of the loop-type magnetic field sensor and the active integrator operated by a differential amplifier. The theoretical principle and design rule of the time-varying magnetic field measuring device and the calibration apparatus are introduced. From the calibration experiments, the frequency bandwidth of the full measuring system ranges from 270 Hz to about 2.3 MHz and the response sensitivity for magentic field strength is 128 $mV/{\mu}T$, respectively, and the calculated B-field values in the center of the loop-type sensor versus the the applied current made with a region of ${\pm}3\;%$error. The actual survey experiments by using lightning impulse current and oscillating impulse current were performed, the results of comparision between the input current waveforms and the magnetic field waveforms are a good agreement with each others and their deviations are less than 0.5 %.

  • PDF

Study on Explosion Behavior of Air-born Rice Bran Dusts according to Ignition Energy (점화에너지 변화에 따른 쌀겨분진의 폭발 거동에 관한 연구)

  • 김정환;김현우;현성호;백동현
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.26-32
    • /
    • 1999
  • We had investigated combustion pro야$\pi$ies of rice bran dusts. Decomposition of rice bran d dusts with temperature were investigated using DSC and the weight loss according to t temperature using TGA in order to find the thermal hazard of rice bran dusts, and the p properties of dust explosion in variation of their dust with the same particle size. Using H Hartman's dust explosion apparatus which estimate dust explosion by electric ignition after m making dust disperse by compressed air, dust explosion experiments have been conducted by v varying concen$\sigma$ation and size of rice br뻐 dust. According to the results for thermodynamic stability of rice bran dust, there are little change of initiation temperature of heat generation 때d heating value for used particle size. But i initiation temperature of heat generation decreased with high heating rate whereas d decomposition heat increased with particle size. Also, the explosion pressure was increased as t the ignition energy increased and average maximum explosion pressure was 13.5 kgv'cnt for 5 BJ/60 mesh and 1.5 뼈Ie미 dust concentration.

  • PDF

A Literature Review for an Emotion Evaluation Protocols Based on Skin Temperature for Home Appliances (피부온을 기반으로 한 가전제품의 감성 평가 프로토콜 수립을 위한 문헌 조사)

  • Jeon, Eun-Jin;Lee, Seung-hoon;Kim, Hee-Eun;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.240-249
    • /
    • 2020
  • This study reviews studies that used skin temperature in order to establish an emotion evaluation protocol based on skin temperature for home appliances. A survey of skin temperature evaluation papers was conducted by the following five stages: (1) keyword search, (2) title screening, (3) abstract screening, (4) full paper screening, and (5) relevance evaluation. Selected papers were reviewed for: purpose, recruitment criteria of participants, the number of participants, apparatus, procedure, measures, analysis methods, and major findings. Thermistor sensors and thermography are used for the measurement of skin temperature. Skin temperature sensors are attached to 4 - 10 locations on the body and their mean of skin temperature is calculated by Ramanatan's 4-point or Hardy & Dubois's 7-point method. Semantic differential (SD) method and thermography measuring facial surface temperature have been used for emotion evaluation. The SD method provides a set of adjective pairs related to a product and evaluates changes in emotion from the use of the product. The range of facial surface analyzed is defined in the thermal image and temperature changes before and after the evaluation are analyzed. The evaluation items of home appliances include form, color, material, aesthetics, satisfaction, novelty, convenience, pleasantness, and excellence. Many existing emotion studies using skin temperature do not apply physiological and psychological methods. This study provides basic data to establish a skin temperature and emotion evaluation protocol by examining literature for skin temperature and evaluation of sensitivity.

Congenital Polyvalvular Disease; Report of A Case (선천성 다발성 판막질환 1예 보고)

  • 김정원;민경석;윤태진;서동만;윤소영;김영휘;고재곤;박인숙;김규래
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.626-629
    • /
    • 2001
  • Congenital polyvalvular disease is a connective tissue disorder affecting more than one heart valve with variable involvement of the entire valvular and subvalvular apparatus. It is frequently associated with the Trisomy 18 and trisomy 13-15 or ventricular septal defect and patent ductus arteriosus. We present an isolated case of congenital polyvalvular disease in a new born baby with a review of the pertinent literatures, which has not been described in Korea. The mass was discovered as a right atrial mass in the prenatal ultrasonography and it was thought to be either a hematoma or a myxoma in the preoperative echocardiography. Microscopic examination of the surgically resected mass showed irregular thickening, nodulation, and additional features of calcification and ossification in the valvular connective tissue on the body of anterior and septal leaflet of tricuspid valve. Congenital polyvalvular disease should be included in the differential diagnosis in cases showing valvular calcification or ossification in the fetal echocardiography.

  • PDF

Fast Consolidation Test Using Seepage Forces : Method and Validation (침투압을 이용한 급속압밀시험 : 방법 및 검증)

  • Lee, Kang-Il;Kim, Tae-Hyung;Znidarcic, Dobroslav
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.4
    • /
    • pp.31-38
    • /
    • 2009
  • A continuous, fast, and convenient experimental method, replacing recent tests such as standard oedometer or self weight consolidation test, is needed for the determination of the consolidation behavior of unformed soft soils. This study introduced the seepage induced fast consolidation test using the flow pump technique. It can obtain the consolidation characteristics of unformed soft soils conveniently and fast. The seepage induced consolidation test apparatus consists of a modified triaxial cell, differential pressure transducer, flow pump, and displacement transducer. The test continuously proceeds with starting seepage forces induced consolidation, loading consolidation, and permeability test on the same sample. In addition, this test result was compared with the standard oedometer test result to make this method valid. From this study it was found that this method is a convenient and time saving effective method for obtaining data required for calculation of consolidation settlement of unformed soft soils.

Modeling of High-throughput Uranium Electrorefiner and Validation for Different Electrode Configuration (고효율 우라늄 전해정련장치 모델링 및 전극 구성에 대한 검증)

  • Kim, Young Min;Kim, Dae Young;Yoo, Bung Uk;Jang, Jun Hyuk;Lee, Sung Jai;Park, Sung Bin;Lee, Han soo;Lee, Jong Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.321-332
    • /
    • 2017
  • In order to build a general model of a high-throughput uranium electrorefining process according to the electrode configuration, numerical analysis was conducted using the COMSOL Multiphysics V5.3 electrodeposition module with Ordinary Differential Equation (ODE) interfaces. The generated model was validated by comparing a current density-potential curve according to the distance between the anode and cathode and the electrode array, using a lab-scale (1kg U/day) multi-electrode electrorefiner made by the Korea Atomic Energy Research Institute (KAERI). The operating temperature was $500^{\circ}C$ and LiCl-KCl eutectic with 3.5wt% $UCl_3$ was used for molten salt. The efficiency of the uranium electrorefining apparatus was improved by lowering the cell potential as the distance between the electrodes decreased and the anode/cathode area ratio increased. This approach will be useful for constructing database for safety design of high throughput spent nuclear fuel electrorefiners.

Clinical and Radiological Features of Diffuse Lacrimal Gland Enlargement: Comparisons among Various Etiologies in 91 Biopsy-Confirmed Patients

  • Sae Rom Chung;Gye Jung Kim;Young Jun Choi;Kyung-Ja Cho;Chong Hyun Suh;Soo Chin Kim;Jung Hwan Baek;Jeong Hyun Lee;Min Kyu Yang;Ho-Seok Sa
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.976-985
    • /
    • 2022
  • Objective: To compare the clinical and radiological features of various etiologies of chronic diffuse lacrimal gland enlargement. Materials and Methods: We retrospectively reviewed 91 consecutive patients who underwent surgical biopsy for chronic diffuse lacrimal gland enlargement and were diagnosed with non-specific dacryoadenitis (DA) (n = 42), immunoglobulin G4-related dacryoadenitis (IgG4-RD) (n = 33), and lymphoma (n = 16). Data on patient demographics, clinical presentation, and CT imaging findings (n = 73) and MRI (n = 43) were collected. The following radiologic features of lacrimal gland enlargement were evaluated: size, unilaterality, wedge sign, angle with the orbital wall, heterogeneity, signal intensity, degree of enhancement, patterns of dynamic contrast-enhanced, and apparent diffusion coefficient value. Radiological features outside the lacrimal glands, such as extra-lacrimal orbital involvement and extra-orbital head and neck involvement, were also evaluated. The clinical and radiological findings were compared among the three diseases. Results: Compared to the DA and IgG4-RD groups, the lymphoma group was significantly older (mean 59.9 vs. 46.0 and 49.4 years, respectively; p = 0.001) and had a higher frequency of unilateral involvement (62.5% vs. 31.0% and 15.2%, respectively; p = 0.004). Compared to the IgG4-RD and lymphoma groups, the DA group had significantly smaller lacrimal glands (2.3 vs. 2.8 and 3.3 cm, respectively; p < 0.001) and a lower proportion of cases with a wedge sign (54.8% vs. 84.8% and 87.5%, respectively; p = 0.005). The IgG4-RD group showed more frequent involvement of the extra-orbital head and neck structures, including the infraorbital nerve (36.4%), paranasal sinus (72.7%), and salivary gland (58.6%) compared to the DA and lymphoma groups (4.8%-28.6%) (all p < 0.005). Conclusion: Patient age, unilaterality, lacrimal gland size, wedge sign, and extra-orbital head and neck involvement differed significantly different between lymphoma, DA, and IgG4-RD. Our results will be useful for the differential diagnosis and proper management of chronic lacrimal gland enlargement.

Development of Pharmaceutical Dosage Forms with Biphasic Drug Release using Double-Melt Extrusion Technology (이중 고온용융 압출 성형된 이중 방출능을 가지는 제형의 개발)

  • Kim, Dong-Wook;Kang, Chin-Yang;Kang, Changmin;Park, Jun-Bom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.228-234
    • /
    • 2016
  • The aim of this study was to develop pharmaceutical dosage forms with a bi-phasic drug using a double extrusion approach. Hot melt extrusion was performed using a co-rotating twin-screw extruder. The. 1st melt extrusion was performed using polymer with a relatively higher Tg, such as HPMC and the 2nd melt extrudate was obtained using the 1st extrudate and polymers with a lower Tg, such as HPMC-AS and PEO. In addition, the formulation with all the content in the same proportion as the double extudate was produced using single extrusion for comparison. Physical characterization was performed on the formulations employing differential scanning calorimetry (DSC). In vitro release tests were studied using a USP Type-I apparatus at $37{\pm}0.5^{\circ}C$ and 100 rpm. The similarity factor (f2) was also used to check the difference statistically. The DSC results indicated that the crystallinity of ibuprofen was changed to an amorphous state after extrusion in both double and single melt extrusion. Double melt extrudate with ibuprofen showed the desired release in acidic media (pH 1.2) in the first two hours and basic (pH 6.8) during six hours. Double melt extrudate with glimepiride showed faster release in 60 min of over 80%, whereas the single extrudate with glimepiride showed retarded release due to the interaction with HPMC. The similarity factor(f2) value was 28.5, which demonstrates that there were different drug release behavior between the double and single extrusion. Consequently, the double melt extrudated formulation was robust and gave the desired drug release pattern.