• Title/Summary/Keyword: Different material

Search Result 9,724, Processing Time 0.037 seconds

Anatomical Variations in the Communicating Rami of the Upper Thoracic Sympathetic Ganglia Related to the Essential Palmar Hyperhidrosis (본태성 수부 다한증에 관련된 상부 흉부교감신경절 교통가지의 해부학적 변이)

  • Cho, Hyun-Min;Kim, Kil-Dong;Lee, Sak;Chung, Kyung-Young
    • Journal of Chest Surgery
    • /
    • v.36 no.3
    • /
    • pp.182-188
    • /
    • 2003
  • Background: Although ramicotomy (division of the rami communicantes of the thoracic sympathetic ganglia) is a selective and physiological surgical method for essential hyperhidrosis, it has some problems such as higher recurrence rates and the different surgical results among the patients and between left and right sides in the same individual. As one of the factors that are related to the differences in surgical result and recurrences, we investigated the anatomical variations of the rami communicantes. The purpose of this study is to help develop new surgical methods to decrease surgical differences among the patients or between the left and right sides of the same individual and recurrence rates in the clinical application of ramicotomy. Material and Method: We dissected 118 thoracic sympathetic chains in 59 adult Korean cadavers (male: 33, female: 26) to examine the anatomical variations of the rami communicantes from the second to the fourth thoracic sympathetic ganglia that have major components innervating to the hands. After the dissection of bilateral thoracic sympathetic chains, we compared the anatomy of left and right sides and examined the anatomical variations of rami communicantes. Result: The number and variation of communicating rami connecting the spinal nerves and the second sympathetic thoracic ganglion were much larger than lower levels. There was considerably less variability in the anatomy of the rami communicantes at successive levels. Among the 59 cadavers dissected, only 14.3% (9/59) had similar anatomy of thoracic sympathetic chains at both sides. As the components related to the essential palmar hyperhidrosis, intrathoracic nerve of Kuntz from the second thoracic sympathetic ganglion to the first intercostal nerve or brachial plexus were observed in 55.9% (66/118). The incidence of descending rami communicates from the second thoracic sympathetic ganglion to the third intercostal nerve and from the third thoracic sympathetic ganglion to the fourth intercostal nerve were 49.2% (58/118) and 28.0% (33/118). And the incidence of ascending rami communicates from the third thoracic sympathetic ganglion to the second intercostal nerve and from the fourth thoracic sympathetic ganglion to the third intercostal nerve were 6.8% (8/118) and 3.4% (4/118), respectively. Conclusion: Based on the various anatomical evidences of the rami communicantes from this study, only the ramicotomy at the third sympathetic ganglion level is insufficient for the treatment of the essential palmar hyperhidrosis to decrease the difference of surgical results and recurrences. When one is planning to perform the ramicotomy for the essential palmar hyperhidrosis, it is advantageous to divide the intrathoracic nerve of Kuntz on the second rib and the descending or ascending rami communicantes on the third and the fourth ribs as well as all the communicating rami from the third sympathetic ganglion.

Clinical Analysis of Repeated Heart Valve Replacement (심장판막치환술 후 재치환술에 관한 임상연구)

  • Kim, Hyuck;Nam, Seung-Hyuk;Kang, Jeong-Ho;Kim, Young-Hak;Lee, Chul-Burm;Chon, Soon-Ho;Shinn, Sung-Ho;Chung, Won-Sang
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.817-824
    • /
    • 2007
  • Background: There are two choices for heart valve replacement-the use of a tissue valve and the use of a mechanical valve. Using a tissue valve, additional surgery will be problematic due to valve degeneration. If the risk of additional surgery could be reduced, the tissue valve could be more widely used. Therefore, we analyzed the risk factors and mortality of patients undergoing repeated heart valve replacement and primary replacement. Material and Method: We analyzed 25 consecutive patients who underwent repeated heart valve replacement and 158 patients who underwent primary heart valve replacement among 239 patients that underwent heart vale replacement in out hospital from January 1995 to December 2004. Result: There were no differences in age, sex, and preoperative ejection fraction between the repeated valve replacement group of patients and the primary valve replacement group of patients. In the repeated valve replacement group, the previously used artificial valves were 3 mechanical valves and 23 tissue valves. One of these cases had simultaneous replacement of the tricuspid and aortic valve with tissue valves. The mean duration after a previous operation was 92 months for the use of a mechanical valve and 160 months for the use of a tissue valve. The mean cardiopulmonary bypass time and aortic cross clamp time were 152 minutes and 108 minutes, respectively, for the repeated valve replacement group of patients and 130 minutes and 89 minutes, respectively, for the primary valve replacement group of patients. These results were statistically significant. The use of an intra aortic balloon pump (IABP) was required for 2 cases (8%) in the repeated valve replacement group of patients and 6 cases (3.8%) in the primary valve replacement group of patients. An operative death occurred in one case (4%) in the repeated valve replacement group of patients and occurred in nine cases (5.1%) in the primary valve replacement group of patients. Among postoperative complications, the need for mechanical ventilation over 48 hours was different between the two groups. The mean follow up period after surgery was $6.5{\pm}3.2$ years. The 5-year survival of patients in the repeated valve replacement group was 74% and the 5-year survival of patients in the primary valve replacement group was 95%. Conclusion: The risk was slightly increased, but there was little difference in mortality between the repeated and primary heart valve replacement group of patients. Therefore, it is necessary to reconsider the issue of avoiding the use of a tissue valve due to the risk of additional surgery, and it is encouraged to use the tissue valve selectively, which has several advantages over the use of a mechanical valve. In the case of a repeated replacement, however, the mortality rate was high for a patient whose preoperative status was not poor. A proper as sessment of cardiac function and patient status is required after the primary valve replacement. Subsequently, a secondary replacement could then be considered.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

The Effect of Retailer-Self Image Congruence on Retailer Equity and Repatronage Intention (자아이미지 일치성이 소매점자산과 고객의 재이용의도에 미치는 영향)

  • Han, Sang-Lin;Hong, Sung-Tai;Lee, Seong-Ho
    • Journal of Distribution Research
    • /
    • v.17 no.2
    • /
    • pp.29-62
    • /
    • 2012
  • As distribution environment is changing rapidly and competition is more intensive in the channel of distribution, the importance of retailer image and retailer equity is increasing as a different competitive advantages. Also, consumers are not functionally oriented and that their behavior is significantly affected by the symbols such as retailer image which identify retailer in the market place. That is, consumers do not choose products or retailers for their material utilities but consume the symbolic meaning of those products or retailers as expressed in their self images. The concept of self-image congruence has been utilized by marketers and researchers as an aid in better understanding how consumers identify themselves with the brands they buy and the retailer they patronize. Although self-image congruity theory has been tested across many product categories, the theory has not been tested extensively in the retailing. Therefore, this study attempts to investigate the impact of self image congruence between retailer image and self image of consumer on retailer equity such as retailer awareness, retailer association, perceived retailer quality, and retailer loyalty. The purpose of this study is to find out whether retailer-self image congruence can be a new antecedent of retailer equity. In addition, this study tries to examine how four-dimensional retailer equity constructs (retailer awareness, retailer association, perceived retailer quality, and retailer loyalty) affect customers' repatronage intention. For this study, data were gathered by survey and analyzed by structural equation modeling. The sample size in the present study was 254. The reliability of the all seven dimensions was estimated with Cronbach's alpha, composite reliability values and average variance extracted values. We determined whether the measurement model supports the convergent validity and discriminant validity by Exploratory factor analysis and Confirmatory Factor Analysis. For each pair of constructs, the square root of the average variance extracted values exceeded their correlations, thus supporting the discriminant validity of the constructs. Hypotheses were tested using the AMOS 18.0. As expected, the image congruence hypotheses were supported. The greater the degree of congruence between retailer image and self-image, the more favorable were consumers' retailer evaluations. The all two retailer-self image congruence (actual self-image congruence and ideal self-image congruence) affected customer based retailer equity. This result means that retailer-self image congruence is important cue for customers to estimate retailer equity. In other words, consumers are often more likely to prefer products and retail stores that have images similar to their own self-image. Especially, it appeared that effect for the ideal self-image congruence was consistently larger than the actual self-image congruence on the retailer equity. The results mean that consumers prefer or search for stores that have images compatible with consumer's perception of ideal-self. In addition, this study revealed that customers' estimations toward customer based retailer equity affected the repatronage intention. The results showed that all four dimensions (retailer awareness, retailer association, perceived retailer quality, and retailer loyalty) had positive effect on the repatronage intention. That is, management and investment to improve image congruence between retailer and consumers' self make customers' positive evaluation of retailer equity, and then the positive customer based retailer equity can enhance the repatonage intention. And to conclude, retailer's image management is an important part of successful retailer performance management, and the retailer-self image congruence is an important antecedent of retailer equity. Therefore, it is more important to develop and improve retailer's image similar to consumers' image. Given the pressure to provide increased image congruence, it is not surprising that retailers have made significant investments in enhancing the fit between retailer image and self image of consumer. The enhancing such self-image congruence may allow marketers to target customers who may be influenced by image appeals in advertising.

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

The Comparative Studies on Hatched Silkworm Dominance Seperation against Sex Seperation to meet Silk Promotion (잠견생산성 개선을 위한 의잠우열분리와 자웅분리의 비교연구)

  • Choe, Byong-Hee
    • Journal of Sericultural and Entomological Science
    • /
    • v.15 no.2
    • /
    • pp.21-28
    • /
    • 1973
  • This report is prepared to promote cocoon natures for the use of silk reeling material. It is easily understandable that there must be disuniformity composed with superior group and inferior group in commercial silkworms. If such different groups be seperated by some method, it would be a great contribution for the cocoon production. For a comparative purpose, silkworm sex seperation carried out because male silkworms produce more silk than female worms. The author has developed a new chemical reagent available for the seperation of superior group and inferior group from commercial silkworms, which he has named it as Better Hybrid Controller (BHC). The obtained comparative results are summarized as followings. 1. Basic investigation of BHC application a) In case BHC applied with hybrid worms and pure line, the former one starts to adapt mulberry leaves earlyer than pure line variety. b) The mulberry adapting interval distribution of pure line worms after BHC application showed U type distribution, but hybrid worms showed L type or Poisson's distribution. c) In case of BHC application with silkworms, the longer period application is, the duller distribution was formed. d) When silkworms are seperated in two groups by use of BHC application, the earlyer mulberry adapted group is seemed as stronger than the other part and the group ratio is 2 : 1. 2. Comparation between sex seperation result and better hydrid control (BHC) seperation result. a) The cocoon shell per cent of male worm group showed betweer result than the female group but only 0.4% difference between sexes. b) The cocoon shell per cent of superior group, seperated by BHC, showed 0.7% more than the inferior group. c) The average cocoon shell per cent of BHC treated cocoons showed much more than the Control group as 1.6∼2.4% increase. Enven the inferior group showed better result than the Control. d) Such unexpected result is considered to be the result that BHC application is activating some thing with silkworm physiology. e) On the ether hand, the result of sexes seperated groups or male worm group did not show desirable conclusion as far as cocoon shell per cent is concerned. f) However, when the male group was reeled as silk, it showed much better silk yield or silk per cent of cocoon than the female group as much as one per cent difference between by sexes. Such result was brought by superior silk yield from cocoon shell as much as 87.4%. g) On the other hand, the male group showed lowest non breaking reelable ratio (63%) among all group comparation. h) When we compare cocoon qualities by sex seperation and BHC seperation against the Control, there is no qualitative change, but BHC group showed quantitative promotion with cocoon bave length as much as about hundred meters. i) In case of calculation for productive income of cocoon production, BHC applied group showed about ten per cent income promotion more than the Control. The sexes seperated group, however, showed rather negative result because the male cocoon produced poor weight per box eggs which could not cover it by the inclose of silk yield of it. j) So, the BHC application with the fetched worm stage brought about big promotion for cocoon production. k) BHC method may be used either for seperation purpose or quantitative promotion with whole silk-worms. 3. Only male silkworms rearing did not show desirable productivity, so there is no reason to work out it in the fetching stage of worm.

  • PDF

Determination of Cost and Measurement of nursing Care Hours for Hospice Patients Hospitalized in one University Hospital (일 대학병원 호스피스 병동 입원 환자의 간호활동시간 측정과 원가산정)

  • Kim, Kyeong-Uoon
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.6 no.3
    • /
    • pp.389-404
    • /
    • 2000
  • This study was designed to determine the cost and measurement of nursing care hours for hospice patients hostpitalized in one university hospital. 314 inpatients in the hospice unit 11 nursing manpower were enrolled. Study was taken place in C University Hospital from 8th to 28th, Nov, 1999. Researcher and investigator did pilot study for selecting compatible hospice patient classification indicators. After modifying patient classification indicators and nursing care details for general ward, approved of content validity by specialist. Using hospice patient classification indicators and per 5 min continuing observation method, researcher and investigator recorded direct nursing care hours, indirect nursing care hours, and personnel time on hospice nursing care hours, and personnel time on hospice nursing care activities sheet. All of the patients were classified into Class I(mildly ill), Class II (moderately ill), Class III (acutely ill), and Class IV (critically ill) by patient classification system (PCS) which had been carefully developed to be suitable for the Korean hospice ward. And then the elements of the nursing care cost was investigated. Based on the data from an accounting section (Riccolo, 1988), nursing care hours per patient per day in each class and nursing care cost per patient per hour were multiplied. And then the mean of the nursing care cost per patient per day in each class was calculated. Using SAS, The number of patients in class and nursing activities in duty for nursing care hours were calculated the percent, the mean, the standard deviation respectively. According to the ANOVA and the $Scheff{\'{e}$ test, direct nursing care hours per patient per day for the each class were analyzed. The results of this study were summarized as follows : 1. Distribution of patient class : class IN(33.5%) was the largest class the rest were class II(26.1%) class III(22.6%), class I(17.8%). Nursing care requirements of the inpatients in hospice ward were greater than that of the inpatients in general ward. 2. Direct nursing care activities : Measurement ${\cdot}$ observation 41.7%, medication 16.6%, exercise ${\cdot}$ safety 12.5%, education ${\cdot}$ communication 7.2% etc. The mean hours of direct nursing care per patient per day per duty were needed ; 69.3 min for day duty, 64.7 min for evening duty, 88.2 min for night duty, 38.7 min for shift duty. The mean hours of direct nursing care of night duty was longer than that of the other duty. Direct nursing care hours per patient per day in each class were needed ; 3.1 hrs for class I, 3.9 hrs for class II, 4.7 hrs for class III, and 5.2 hrs for class IV. The mean hours of direct nursing care per patient per day without the PCS was 4.1 hours. The mean hours of direct nursing care per patient per day in class was increased significantly according to increasing nursing care requirements of the inpatients(F=49.04, p=.0001). The each class was significantly different(p<0.05). The mean hours of direct nursing care of several direct nursing care activities in each class were increased according to increasing nursing care requirements of the inpatients(p<0.05) ; class III and class IV for medication and education ${\cdot}$ communication, class I, class III and class IV for measurement ${\cdot}$ observation, class I, class II and class IV for elimination ${\cdot}$ irrigation, all of class for exercise ${\cdot}$ safety. 3. Indirect nursing care activities and personnel time : Recognization 24.2%, house keeping activity 22.7%, charting 17.2%, personnel time 11.8% etc. The mean hours of indirect nursing care and personnel time per nursing manpower was 4.7 hrs. The mean hours of indirect nursing care and personnel time per duty were 294.8 min for day duty, 212.3 min for evening duty, 387.9 min for night duty, 143.3 min for shift duty. The mean of indirect nursing care hours and personnel time of night duty was longer than that of the other duty. 4. The mean hours of indirect nursing care and personnel time per patient per day was 2.5 hrs. 5. The mean hours of nursing care per patient per day in each class were class I 5.6 hrs, class II 6.4 hrs, class III 7.2 hrs, class IV 7.7 hrs. 6. The elements of the nursing care cost were composed of 2,212 won for direct nursing care cost, 267 won for direct material cost and 307 won for indirect cost. Sum of the elements of the nursing care cost was 2,786 won. 7. The mean cost of the nursing care per patient per day in each class were 15,601.6 won for class I, 17,830.4 won for class II, 20,259.2 won for class III, 21,452.2 won for class IV. As above, using modified hospice patient classification indicators and nursing care activity details, many critical ill patients were hospitalized in the hospice unit and it reflected that the more nursing care requirements of the patients, the more direct nursing care hours. Emotional ${\cdot}$ spiritual care, pain ${\cdot}$ symptom control, terminal care, education ${\cdot}$ communication, narcotics management and delivery, attending funeral ceremony, the major nursing care activities, were also the independent hospice service. But it is not compensated by the present medical insurance system. Exercise ${\cdot}$ safety, elimination ${\cdot}$ irrigation needed more nursing care hours as equal to that of intensive care units. The present nursing management fee in the medical insurance system compensated only a part of nursing car service in hospice unit, which rewarded lower cost that that of nursing care.

  • PDF

Development and Research into Functional Foods from Hydrolyzed Whey Protein Powder with Sialic Acid as Its Index Component - I. Repeated 90-day Oral Administration Toxicity Test using Rats Administered Hydrolyzed Whey Protein Powder containing Normal Concentration of Sialic Acid (7%) with Enzyme Separation Method - (Sialic Acid를 지표성분으로 하는 유청가수분해단백분말의 기능성식품 개발연구 - I. 효소분리로 7% Siailc Acid가 표준적으로 함유된 유청가수분해단백분말(7%)의 랫드를 이용한 90일 반복경구투여 독성시험 평가 연구 -)

  • Noh, Hye-Ji;Cho, Hyang-Hyun;Kim, Hee-Kyong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.99-116
    • /
    • 2016
  • We herein performed animal safety assessment in accordance with Good Laboratory Practice (GLP) regulations with the aim of developing sialic acid from glycomacropeptide (hereafter referred to as "GMP") as an index ingredient and functional component in functional foods. GMP is a type of whey protein derived from milk and a safe food, with multiple functions, such as antiviral activity. A test substance was produced containing 7% (w/w) sialic acid and mostly-hydrolyzed whey protein (hereafter referred to as "7%-GNANA") by enzymatic treatment of substrate GMP. The maximum intake test dose level was selected based on 5,000 mg/kg/day dose set for male NOEL (no-observed-effect-level) and female NOAEL (no-observed-adverse-effect-level) determined by a dose-range finding (DRF) test (GLP Center of Catholic University of Daegu, Report No. 15-NREO-001) that was previously conducted with the same test substance. To evaluate the toxicity of a repeated oral dose of the test substance in connection with the previous DRF study, 1,250, 2,500, and 5,000 mg/kg of the substance were administered by a probe into the stomachs of 6-week-old SPF Sprague-Dawley male and female rats for 90 d. Each test group consisted of 10 male and 10 female rats. To determine the toxicity index, all parameters, such as observation of common signs; measurements of body weight and food consumption; ophthalmic examination; urinalysis, electrolyte, hematological, and serum biochemical examination; measurement of organ weights during autopsy; and visual and histopathological examinations were conducted according to GLP standards. After evaluating the results based on the test toxicity assessment criteria, it was determined that NOAEL of the test substance, 7%-GNANA, was 5,000 mg/kg/day, for both male and female rats. No animal death was noted in any of the test groups, including the control group, during the study period, and there was no significant difference associated with test substance, as compared with the control group, with respect to general symptoms, body weight changes, food consumption, ophthalmic examination, urinalysis, hematological and serum biochemical examination, and electrolyte and blood coagulation tests during the administration period (P<0.05). As assessed by the effects of the test substance on organ weights, food consumption, autopsy, and histopathological safety, change in kidney weight as an indicator of male NOAEL revealed up to 20% kidney weight increase in the high-dose group (5,000 mg/kg/day) compared with the change in the control group. However, it was concluded that this effect of the test substance was minor. In the case of female rats, reduction of food consumption, increase of kidney weight, and decrease of thymus weight were observed in the high-dose group. The kidney weight increased by 10.2% (left) and 8.9% (right) in the high-dose group, with a slight dose-dependency compared with that of the control group. It was observed that the thymus weight decreased by 25.3% in the high-dose group, but it was a minor test substance-associated effect. During the autopsy, botryoid tumor was detected on the ribs of one subject in the high-dose group, but we concluded that the tumor has been caused by a naturally occurring (non-test) substance. Histopathological examination revealed lesions on the kidney, liver, spleen, and other organs in the low-dose test group. Since these lesions were considered a separate phenomenon, or naturally occurring and associated with aging, it was checked whether any target organ showed clear symptoms caused by the test substance. In conclusion, different concentrations of the test substance were fed to rats and, consequently, it was verified that only a minor effect was associated with the test substance in the high-dose (5,000 mg/kg/day) group of both male and female rats, without any other significant effects associated with the test substance. Therefore, it was concluded that NOAEL of 7%-GNANA (product name: Helicobactrol) with male and female rats as test animals was 5,000 mg/kg/day, and it thus was determined that the substance is safe for the ultimate use as an ingredient of health functional foods.

Ischemic Preconditioning and Its Relation to Glycogen Depletion (허혈성 전처치와 당원 결핍과의 관계)

  • 장대영;김대중;원경준;조대윤;손동섭;양기민;라봉진;김호덕
    • Journal of Chest Surgery
    • /
    • v.33 no.7
    • /
    • pp.531-540
    • /
    • 2000
  • Baclgrpimd; Recent studies have suggested that the cardioprotective effect of ischemic preconditioning(IP) is closely related to glycogen depletion and attenuation of intracellular acidosis. In the present study, the authors tested this hypothesis by perfusion isolated rabbit hearts with glucose(G) is closely related to glycogen depletion and attenuation of intracellular acidosis. In the present study, the authors tested this hypothesis by perfusion isolated rabbit hearts with glucose(G)-free perfusate. Material and Method; Hearts isolated from New Zealand white rabbits(1.5~2.0 kg body weight) were perfused with Tyrode solution by Langendorff technique. After stabilization of baseline hemodynamics, the hearts were subjected to 45 min global ischemia followed by 120 min reperfusion with IP(IP group, n=13) or without IP(ischemic control group, n=10). IP was induced by single episode of 5 min global ischemia and 10 min reperfusion. In the G-free preconditioned group(n=12), G depletion was induced by perfusionwith G-free Tyrode solution for 5 min and then perfused with G-containing Tyrode solution for 10 min; and 45 min ischemia and 120 min reperfusion. Left ventricular functionincluding developed pressure(LVDP), dP/dt, heart rate, left ventricular end-distolic pressure(LVEDP) and coronary flow (CF) were measured. Myocardial cytosolic and membrane PKC activities were measured by 32P-${\gamma}$-ATP incorporation into PKC-specific peptide and PKC isozymes were analyzed by Western blot with monoclonal antibodies. Infarct size was determined by staining with TTC(tetrazolium salt) and planimetry. Data were analyzed by one-way analysis of variance (ANOVA) and Turkey's post-hoc test. Result ; In comparison with the ischemic control group, IP significantly enhanced functional recovery of the left ventricle; in contrast, functional significantly enhanced functional recovery of the left ventricle; in contrast, functional recovery were not significantly different between the G-free preconditioned and the ischemic control groups. However, the infarct size was significantly reduced by IP or G-free preconditioning(39$\pm$2.7% in the ischemic control, 19$\pm$1.2% in the IP, and 15$\pm$3.9% in the G-free preconditioned, p<0.05). Membrane PKC activities were increased significantly after IP (119%), IP and 45 min ischemia(145%), G-free [recpmdotopmomg (150%), and G-free preconditioning and 45 min ischemia(127%); expression of membrane PKC isozymes, $\alpha$ and $\varepsilon$, tended to be increased after IP or G-free preconditioning. Conclusion; These results suggest that in isolated Langendorff-perfused rabbit heart model, G-free preconditioning (induced by single episode of 5 min G depletion and 10 min repletion) colud not improve post-ischemic contractile dysfunction(after 45-minute global ischemia); however, it has an infarct size-limiting effect.

  • PDF

20 Years Surgical Experiences for Ebstein's Anomaly (엡스타인 기형의 20년 수술 치험)

  • Lee, Sak;Park, Han-Ki;Lee, Chang-Young;Chang, Byung-Chul;Park, Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.280-287
    • /
    • 2007
  • Background: We retrospectively evaluated the clinical results of surgically managing patients with Ebstein's anomaly. Material and Method: Between Feb. f 984 and June 2006, 50 patients who underwent surgical treatment for Ebstein's anomaly at Yonsei Cardiovascular Center were retrospectively reviewed. The mean age of the patients was 26.9 years and 19 patients were male, Associated anomalies included atrial septal defect (33), patent ductus arteriosus (2), ventricular septal defect (1), and pulmonary stenosis (4), and 90%, (45/50) of the patients had more than a moderate degree of tricuspid regurgitation. Carpentier type A was present in 6 patients, type B in 26, type C in 14 and type D in 4. Ten patients were associated with WPW syndrome. Conservative surgery was possible in 31 patients (tricuspid annuloplasty, plication of the atrialized RV), Fontan's operation was peformed in 4 patients, tricuspid valve replacement was done in 12 and palliative surgery was done in 2 patients. Thirteen patients were associated with hi-directional cavopulmonary shunt (BCPS: one and a half ventricular repairs): 10 patients with WPW syndrome and 4 patients with atrial fibrillation underwent concomitant ablation. Result: The postoperative median NYHA functional class $(3{\rightarrow}1)$ and the mean cardio-thoracic ratio $(0.65{\rightarrow}0.59)$ were decreased significantly (p<0.001, p=0.014). The mean oxygen saturation $(86.6{\rightarrow}94.1%)$, and median TR grade $(4{\rightarrow}1)$ were also significantly improved (p=0.004, p<0.001). For comparison of BCPS and conservative surgery, the preoperative right ventricular pressure (33.0 vs. 41.3 mmHg), the ICU stay (2.80 vs. 1.89 days), the hospital say (10.6 vs. 16.8 days), and the left ventricular ejection fraction (64.3 vs. 72.8%) were statistically different. Postoperative mortality occurred in 3 patients (6%) due to biventricular failure in 2 patients and sepsis in the other patient. The mean follow up duration was 101.5 months, and one patient died of Fontan failure and 6 patients required reoperation (bioprosthetic degenerative change (2) and Fontan conversion (4)). The overall survival rate at 10 years was 90.2%, the freedom from reoperation rate and rate of cardiac related events were 78.9% and 49.2%, respectively. Conclusion: Surgical management of Ebstein's anomaly can be performed safely, and the associated BCPS may be helpful for high-risk patients. Adequate application of surgical management may increase the long-term survival with a reduced rate of reoperation.