• Title/Summary/Keyword: Different irradiation

Search Result 1,061, Processing Time 0.026 seconds

The Studies of Irradiation Hardening of Stainless Steel Reactor Internals under Proton and Xenon Irradiation

  • Xu, Chaoliang;Zhang, Lu;Qian, Wangjie;Mei, Jinna;Liu, Xiangbing
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.758-764
    • /
    • 2016
  • Specimens of stainless steel reactor internals were irradiated with 240 keV protons and 6 MeV Xe ions at room temperature. Nanoindentation constant stiffness measurement tests were carried out to study the hardness variations. An irradiation hardening effect was observed in proton- and Xe-irradiated specimens and more irradiation damage causes a larger hardness increment. The Nix-Gao model was used to extract the bulk-equivalent hardness of irradiation-damaged region and critical indentation depth. A different hardening level under H and Xe irradiation was obtained and the discrepancies of displacement damage rate and ion species may be the probable reasons. It was observed that the hardness of Xe-irradiated specimens saturate at about 2 displacement/atom (dpa), whereas in the case of proton irradiation, the saturation hardness may be more than 7 dpa. This discrepancy may be due to the different damage distributions.

A Study of Fatigue Strength Improvement for Cr-Mo Steel in Long Term service (장기간 사용한 Cr-Mo강의 피로강도향상 방법에 관한 연구)

  • 진영준
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.27-35
    • /
    • 2001
  • For the purpose of healing the degradation part, $CO_2$ laser beam was irradiated with different irradiation condition (porer, diameter, velocity and beam type) to find out optimum irradiation condition. The test series of hardness, residual stress measurement, and fatigue were carried out after the irradiation. Experimental results show that micro-hardness values on the surface of the irradiated specimens m approximately 2.5 times higher than those of un-irradiated ones. Fatigue tests show that the fatigue life was improved by the compressive residual stress after laser beam irradiation. However, some specimens with different conditions show the shorter fatigue life. It means that laser beam irradiation with optimum irradiation condition and optimum absorb energy, Q can improve the fatigue strength.

  • PDF

Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes (진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교)

  • Kim, Yong;Seo, Tae-Beom;Yun, Seong-Eun;Kim, Young-Min
    • New & Renewable Energy
    • /
    • v.2 no.1 s.5
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

Development of a gamma irradiation loop to evaluate the performance of a EURO-GANEX process

  • Sanchez-Garcia, I.;Galan, H.;Nunez, A.;Perlado, J.M.;Cobos, J.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1623-1634
    • /
    • 2022
  • A new irradiation loop design has been developed, which provides the ability to carry out radiolytic resistance studies of extraction systems simulating process relevant conditions in an easy and simple way. The step-by-step loop configuration permits an easy modification of settings and has a relative low volume requirement. This irradiation loop has been initially set up to test the main EURO-GANEX process steps: the lanthanide (Ln) and actinide (An) co-extraction followed by the transuranic (TRU) stripping. The performance and changes in the composition have been analyzed during the irradiation experiment by different techniques: gamma spectroscopy and ICP-MS for the extraction and corrosion behavior of the full system, and HPLC-MS and Raman spectroscopy to determine the degradation of the organic and aqueous solvents, respectively. The Ln and An co-extraction step and the corrosion that occurred during the first irradiation step revealed the favorable expected results according to literature. The effects of acidity changes occurred during the irradiation process, the presence of stainless corrosion products in solution as well as the new possible degradation compounds have been explored in the An stripping step. The results obtained demonstrate the importance of developing realistic irradiation experiments where different factors affecting the performance can be easily studied and isolated.

Effects of titanium oxide nanoparticles on Oryzias latipes embryos and sac-fry under different irradiation conditions

  • Nam, Sun-Hwa;Shin, Yu-Jin;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.426-431
    • /
    • 2017
  • Some phototoxicity of titanium dioxide nanoparticles ($TiO_2$ NPs) has been reported in recent years in studies with fish embryos or larvae. However, it is necessary to focus on the potential effects of embryonic exposure due to irreversible abnormalities and mortalities observed in sac-fry, and to expand various fish embryos to generate multiple test species. The aim of this study was to evaluate the effects of $TiO_2$ NPs under different irradiation conditions in exposed Oryzias latipes (O. latipes) at the embryonic and sac-fry stages. The effects of different irradiation conditions were observed using ultra-violet (UV) and visible light, and the corresponding effects were monitored by determining cumulative mortality and abnormality. O. latipes were exposed for 8 d to 0, 1, 5, 10, or 50 mg/L $TiO_2$ NPs under UV ($4,818.86mW/m^2$ at the bottom of clear vials) or visible light, after which the embryos were transferred to NP-free embryo-rearing solution until 16 days post fertilization (dpf). Abnormalities of embryos and sac-fry increased at high $TiO_2$ NP concentrations under UV irradiation, compared to control samples treated with visible light or UV irradiation alone. This work provides information regarding the phototoxicity of $TiO_2$ NPs using O. latipes at the embryonic and sac-fry stages.

Effects of Sensory Qualities of Ready-to-Eat Chicken Cooked by Different Culinary Methods and Gamma-irradiated at 10 kGy (조리 방법별 즉석 취식 닭고기의 조리 직후 감마선 조사가 관능적 품질에 미치는 영향)

  • Park, Kyung-Sook
    • Journal of Radiation Industry
    • /
    • v.6 no.4
    • /
    • pp.311-316
    • /
    • 2012
  • The purpose of this study was to compare the sensory effects of different culinary methods such as electric pan cooking and charcoal roasting on gamma irradiated ready-to-eat chicken at 10 kGy. Evlauation of sensory properties were measured by estimating the organoleptic characteristics and physicochemical properties (TBARS, hardness and color different matters). The results showed that gamma irradiation after charcoal-roasting could more effectively moderate the decrease of sensory qualities and reduce off-flavor of ready-to-eat chicken than gamma irradiation after following electric pan cooking. These results suggest that gamma irradiation after charcoal broiling can be an effective culinary method for the preparation of ready-to-eat chicken.

In-situ TEM investigation of zirconium alloy under Kr+ single-beam and Kr+-He+ dual-beam synergetic irradiation

  • Zhen Wang;Qing-Xue Yan;Zhong-Qiang Fang;Chen-Yang Lu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3129-3138
    • /
    • 2024
  • The in-situ TEM irradiation experiments of zirconium alloy were conducted at 573 K, 673 K, and 773 K utilizing a 400 keV Kr + single beam and a 400 keV Kr+ and 30 keV He + dual beam. The results show that a large number of dislocation loops have been characterized in the matrix of the zirconium alloy under irradiation. With increasing the irradiation damage dose, some dislocation loops have reacted with one another to form a larger dislocation loop, which has finally formed dislocation lines or other defect structures. In zirconium alloys irradiated with Kr + single beam and Kr+ and He + dual-beam radiation, the proportion of <a> type dislocation loops with different Burgers vectors is essentially the same at low damage doses, but the proportion of interstitial type dislocation loops with the same Burgers vectors is obviously different. The amorphization of the second phase and the dissolution of the small-sized second phase were also pointed out. With the increase in temperature, the density of the dislocation loop in zirconium alloy gradually decreases, and the size of dislocation loop first increases and then decreases. Kr+ and He + dual beam irradiation increases the size of dislocation loops but decreases their density as compared with Kr + single beam irradiation.

Impact of UV-C Irradiation on Bacterial Disinfection in a Drinking Water Purification System

  • Hyun-Joong Kim;Hee-Won Yoon;Min-A Lee;Young-Hoon Kim;Chang Joo Lee
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.106-113
    • /
    • 2023
  • The supply of microbiological risk-free water is essential to keep food safety and public hygiene. And removal, inactivation, and destruction of microorganisms in drinking water are key for ensuring safety in the food industry. Ultraviolet-C (UV-C) irradiation is an attractive method for efficient disinfection of water without generating toxicity and adversely affecting human health. In this study, the disinfection efficiencies of UV-C irradiation on Shigella flexneri (Gram negative) and Listeria monocytogenes (Gram positive) at various concentrations in drinking water were evaluated using a water purifier. Their morphological and physiological characteristics after UV-C irradiation were observed using fluorescence microscopy and flow cytometry combined with live/dead staining. UV-C irradiation (254 nm wavelength, irradiation dose: 40 mJ/cm2) at a water flow velocity of 3.4 L/min showed disinfection ability on both bacteria up to 108 CFU/4 L. And flow cytometric analysis showed different physiological shift between S. flexneri and L. monocytogenes after UV-C irradiation, but no significant shift of morphology in both bacteria. In addition, each bacterium revealed different characteristics with time-course observation after UV-C irradiation: L. monocytogenes dramatically changed its physiological feature and seemed to reach maximum damage at 4 h and then recovered, whereas S. flexneri seemed to gradually die over time. This study revealed that UV-C irradiation of water purifiers is effective in disinfecting microbial contaminants in drinking water and provides basic information on bacterial features/responses after UV-C irradiation.

Experimental investigation on the degradation of SiGe LNAs under different bias conditions induced by 3 MeV proton irradiation

  • Li, Zhuoqi;Liu, Shuhuan;Ren, Xiaotang;Adekoya, Mathew Adefusika;Zhang, Jun;Liu, Shuangying
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.661-665
    • /
    • 2022
  • The 3 MeV proton irradiation effects on SiGe low noise amplifier (LNA) (NXP BGU7005) performance under different voltage supply VCC (0 V, 2.5 V) conditions were firstly experimental studied in this present work. The S parameters including S11, S22, S21, 1 dB compression point and noise figure (NF) of the test samples under different bias voltage supply were measured and compared before and after 3 MeV proton irradiation. The total proton irradiation fluence was 1 × 1015 protons/cm2. The maximum degradation quantities of the gain S21 and NF of the test samples under zero bias are measured respectively 1.6 dB and 1.2 dB. Compared with the samples under 2.5 V bias supply, the maximum degradation of S21 and NF are respectively 1.1 dB and 0.8 dB in the whole frequency band. It is noteworthy that the gain and NF of SiGe LNAs under zero-bias mode suffer enhanced degradation compared with those under normal bias supply. The key influence factors are discussed based on the correlation of the SiGe device and the LNA circuit. Different process of the ionization damage and displacement damage under zero-bias and 2.5 V bias voltage supply contributed to the degradation difference. The underlying physical mechanisms are analyzed and investigated.

Effect of Electron-beam Irradiation on Polymethoxylated Flavones Content of Citrus unshiu Pomaces

  • Kim, Jong-Wan;Kim, Min-Chul;Nam, Ki-Chang;Lee, Seung-Cheol
    • Preventive Nutrition and Food Science
    • /
    • v.14 no.4
    • /
    • pp.362-366
    • /
    • 2009
  • To determine the effect of electron-beam irradiation on the contents of polymethoxylated flavones (PMFs) extracts from citrus pomaces (CP), CP was irradiated at 0, 1, 2, or 5 kGy. Methanol extract of the irradiated CP were prepared and the PMF (nobiletin, sinensetin, and tangeretin) content of the extract was determined. Nobiletin and sinensetin of CP extract significantly increased with irradiation dose-dependent. However, electron-beam irradiation decreased the amount of tangeretin in the CP extract. These data suggest that irradiation can liberate phenolic compounds such as nobiletin or sinensetin, but tangeretin might have different pathway of conversion by irradiation. Therefore, irradiation can be a tool to change the composition of PMFs in CP.