• 제목/요약/키워드: Different Thickness

검색결과 4,569건 처리시간 0.032초

Precise ultrasonic coating and controlled release of sirolimus with biodegradable polymers for drug-eluting stent

  • Joung, Yoon Ki;Jang, Bu Nam;Kang, Jong Hee;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권1호
    • /
    • pp.13-25
    • /
    • 2014
  • In the current study, a drug-eluting stent coated with biodegradable polymers and sirolimus was developed by using an ultrasonic nanocoater and characterized in aspects of surface smoothness and coating thickness. In addition, in vitro release profiles of sirolimus by changing top coating layer with different biodegradable polymers were investigated. Smooth surfaces with variable thickness could be fabricated by optimizing polymer concentration, flow rate, nozzle-tip distance, gas pressure, various solvents and ultrasonic power. Smooth surface could be generated by using volatile solvents (acetone, chloroform, and methylene chloride) or post-treating with solvent vapor. Coating thickness could be controlled by varying injection volume or polymer concentration, and higher concentration could reduce the coating time while obtaining the same thickness. The thickness measurement was the most effectively performed by a conventional cutting method among three different methods that were investigated in this study. Release profiles of sirolimus were effectively controlled by changing polymers for top layer. PLGA made the release rate 3 times faster than PDLLA and PLLA and all top layers prevented burst release at the initial phase of profiles. Our results will provide useful and informative knowledge for developing drug-eluting stents, especially coated with biodegradable polymers.

원통금형의 전자빔 가공을 위한 PR 코팅 및 측정 팁을 이용한 두께측정 (PR Coating for Electron Beam Lithography of Cylindrical Mold and Measuring Coating Thickness of It using Measuring Tip)

  • 이승우;김정오;서정
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1144-1148
    • /
    • 2012
  • Process conditions for generating nano patterns handle different process according to the pattern characteristics, and different process data according to patterns in questions. To efficiently find optimal process conditions for generating nano patterns, process data by experiment is needed consideration of the pattern characteristics concerning the equipment. In particular, coating methods of a cylindrical mold differ from it of a flat plate because of viscosity of coating materials. Also the coating thickness affects nano process and pattern line width. So coating method of coating thickness for cylindrical mold is very important on nano pattern generating. In this study, a method is proposed for coating Photo Resist through the spray in order to coat cylindrical mold and measuring the thickness of coating using measuring tip considering the size of cylindrical mold because there is no method in the existing SEM. The proposed method is applied to a real printed electronics system to verify its accuracy and efficiency.

직물의 조직에 따른 밀도, 두께가 보온성에 미치는 영향 (The Effect of Density and Thickness to the Warmth by different Weaves of Fabric)

  • 한명숙
    • 대한가정학회지
    • /
    • 제12권1호
    • /
    • pp.459-471
    • /
    • 1974
  • This study was carried out on the thermal transmission on account of variation of weaves and researched on the selection of the most suitable weaves for warmth. Also the interrelation among the density, thickness and thermal transmission by different weaves was studied, the author has woven three fundamental weaves, five weaves derived from the fundamental weaves and two special weaves for the purpose of experiment. In weaving of fabrics for experiments the lever type hand loom was used. Testing of texture was carried out according to KS and ASTM. The thermal transmission was also tested by as cooling method which were developed by the author. The conclusions of experiments were as follows. 1. Matt weaves, honey comb weaves and satin weaves having long floating yarns have large cover factor and were thicker. these structures of the weaves were good in warmth. 2. Thermal transmission was reciprocated to the cover factor, thickness and value of cover factor multiplied by thickness : It was found that the weaves of woven fabrics for warmth had better use of satin weaves, Matt weaves, Granite weaves and Honey comb weaves. In the time of warmth is not the first purpose, had better use of Rib weaves. Plain weaves and Twill weaves with thin thickness and high thermal transmission.

  • PDF

Effects of Knee Extension Exercise Using Blood Flow Restriction on the Thickness and Balance Ability of Tendons

  • Park, Jae-Cheol;Kim, Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • 제30권2호
    • /
    • pp.41-46
    • /
    • 2018
  • Purpose: This study examined the effects of knee extension exercise using blood flow restriction on the changes in the thickness and static balance ability of the tendon of the rectus femoris muscle and achilles tendon. Methods: A total of 30 subjects was were divided into two groups of 15 subjects each. The changes in the thickness and balance of their tendons were measured by ultrasonography and balance equipment. The measurements were taken three times: before the experiment, 4 weeks after, and 8 weeks after. The results were analyzed by repeated measure ANOVA, one-way ANOVA was conducted in cases where there were time-to-group interactions in the intra-individual effects test. Results: Significant differences in the thickness of the tendon of the rectus femoris muscle and Achilles tendon were found between the groups, over time, and in the time-to-group interactions (p<0.05). The changes in balance in both feet when the supporting positions between eye-open and eye-closed states were significantly different in the time-to-group interactions (p<0.05), but were not different between the groups (p>0.05). Conclusion: Knee extension exercise using blood flow restriction leads to significant differences in the increase in tendon thickness and changes in balance, indicating that the results of this study can be utilized as basic data for future studies and for rehabilitation treatment at clinics.

합성얼음을 이용한 얼음의 두께와 수선면각 변화에 따른 쇄빙상선 저항특성 연구 (Study on Resistance Performance of Icebreaking Cargo Vessel According to Variation of Thickness and Waterline Angle by Using Synthetic Ice)

  • 신병철;김문찬;이승호;이승기
    • 대한조선학회논문집
    • /
    • 제48권2호
    • /
    • pp.134-140
    • /
    • 2011
  • The present paper deals with characteristics of resistance performance according to the variation of synthetic ice thickness and hull form. The resistance test has been conducted with pack ice condition in Pusan National University towing tank. Waterline angle has been chosen as a main parameter for the variation of hull form characteristics, which is the most important factor especially in icebreaking cargo vessel. The serial comparisons of resistance test have been done with the variation of hull form parameter as well as with the different thickness of synthetic ice. The different trend of resistance performances with increasing of waterline angle has been shown at each synthetic ice thickness. The present test results is expected to be confirmed by comparing the test results in ice tank in the near future.

Voxel-Based Thickness Analysis of Intricate Objects

  • Subburaj, K.;Patil, Sandeep;Ravi, B.
    • International Journal of CAD/CAM
    • /
    • 제6권1호
    • /
    • pp.105-115
    • /
    • 2006
  • Thickness is a commonly used parameter in product design and manufacture. Its intuitive definition as the smallest dimension of a cross-section or the minimum distance between two opposite surfaces is ambiguous for intricate solids, and there is very little reported work in automatic computation of thickness. We present three generic definitions of thickness: interior thickness of points inside an object, exterior thickness for points on the object surface, and radiographic thickness along a view direction. Methods for computing and displaying the respective thickness values are also presented. The internal thickness distribution is obtained by peeling or successive skin removal, eventually revealing the object skeleton (similar to medial axis transformation). Another method involves radiographic scanning along a viewing direction, with minimum, maximum and total thickness options, displayed on the surface of the object. The algorithms have been implemented using an efficient voxel based representation that can handle up to one billion voxels (1000 per axis), coupled with a near-real time display scheme that uses a look-up table based on voxel neighborhood configurations. Three different types of intricate objects: industrial (press cylinder casting), sculpture (Ganesha idol), and medical (pelvic bone) were used for successfully testing the algorithms. The results are found to be useful for early evaluation of manufacturability and other lifecycle considerations.

연안 연승어구에 있어서 아릿줄의 굵기와 길이가 조획에 미치는 영향 (The effect of hooking on thickness and length of branch line in fishing gear of long line at the coastal waters)

  • 양진성;김석종
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.51-58
    • /
    • 2012
  • As a basic study to improve hooking ability of long line fishing gear, which is widely used around Jeju-do coast, the researcher performed hooking experiment of parrot fish by manufacturing and installing 7 kinds of model long line fishing gears, whose thickness of branch line are different and 8 kinds of model long line fishing gear, whose length of branch line are different, in indoor circular aquarium, which is installed for the model experiment of thickness and length of branch line that are various by fishing implement and improper. The hooking rate depending on thickness and length of branch line was calculated and the effect of thickness and length of branch line on hooking rate was analyzed. Its results are as follows. When branch line was thin and long, high hooking rate appeared. In the scope of value setting, the relationship between thickness ($B_t$) of branch line and total hooking rate ($Th_r$) can be shown as following formula as. In the scope of value setting, the relationship between length ($B_t$) of branch line and total hooking rate ($B_t$) can be shown as $Th_r=-20.83B_t+26.04$. Through Pearson correlation analysis, the coefficient of correlation between thickness of branch line and hooking rate was -0.718. Therefore it showed significance in 0.01 significance level. Through Pearson correlation analysis, the coefficient of correlation between length of branch line and hooking rate was 0.431. Therefore it showed significance in 0.01 significance level.

THE EFFECT OF THICKNESS OF THE PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS ON THE TRANSLUCENCY AND MASKING EFFECT

  • Jae, Hyun-Jee;Kim, Sung-Hun;Lee, Seok-Hyung;Pae, Ahran
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.724-734
    • /
    • 2007
  • Statement of problem. Translucency and masking effect of provisional crown and fixed partial denture materials is an important esthetic consideration. But, provisional resin materials differ substantially in their ability to mask underlying colors. Purpose. The purpose of this study was to evaluate the translucency differences of provisional resin materials at various thicknesses and the correlation between the translucency and the masking efficiency. Material and methods. Two polymethyl methacrylate resins (Jet Tooth Shade, Alike) and three resin composites (Protemp 3 Garant, Luxatemp and Revotek LC) were used. Specimens (n=6) were fabricated from each material in 0.3, 0.5, 0.8, 1.0, 1.5, 2.0 and 3.0 mm thickness. The CIELAB parameters of each specimens were measured using a spectrophotometer. The translucency parameter (TP) values and the masking effect $({\Delta}ME^*{_{ab}})$ values were computed and all data were statistically analyzed by one-way ANOVA and the multiple comparisons Scheffe test. The correlation between the thickness and the TP values and the correlation between the thickness and the ${\Delta}ME^*{_{ab}}$ values were also evaluated by correlation analysis and regression analysis. Results. The TP values and the ${\Delta}ME^*{_{ab}}$ values were significantly related to the thickness in all specimens. The TP values were more sensitive to the change of thickness than the ${\Delta}ME^*{_{ab}}$ values. The order of the translucency by brand was different from the order of the masking effect by brand in all thickness groups. Conclusion. Within the limitations of this study, the translucency and masking effect of the provisional resin materials investigated were significantly related to their thickness. The masking effect of provisional resin was correlated with the translucency parameter, but the order of the masking effect by brand was different from the order of the translucency parameter.

표면파의 분산 특성을 이용한 Ni 박막의 두께 측정 (Thickness Measurement of Ni Thin Film Using Dispersion Characteristics of a Surface Acoustic Wave)

  • 박태성;곽동열;박익근;김미소;이승석
    • 비파괴검사학회지
    • /
    • 제34권2호
    • /
    • pp.171-175
    • /
    • 2014
  • 본 연구에서는 박막 표면을 따라 전파하는 표면파의 속도 분산성을 이용하여 박막의 두께를 비파괴적으로 측정할 수 있는 기법을 제안하였다. 표면파의 분산성을 이용하여 박막의 두께를 측정하기 위하여 전자빔증착법(E-beam evaporation)을 이용하여 Si(100) 웨이퍼 위에 니켈의 증착시간을 제어함으로서 두께가 다른 니켈 박막시험편을 제작하였다. 제작된 시험편의 실제 증착된 박막의 두께를 확인하기 위하여 SEM(scanning electron microscope)을 이용하여 박막의 단면사진을 촬영하여 두께를 확인하였다. 그 후에 두께가 다른 시험편에서의 표면파의 속도를 초음파현미경(scanning acoustic microscope)의 V(z) 곡선법을 이용하여 표면파의 속도를 측정하고 실제 측정된 두께와 표면파 속도와의 상관성을 확인하였다. 박막의 두께가 증가함에 따라 표면파의 속도는 감소하는 경향성을 나타내었다. 결론적으로 본 연구에서 제안한 표면파의 속도 분산성을 이용하여 나노 스케일 니켈 박막의 두께를 측정하는 기법이 가능성이 있음을 확인하였다.

Lamina dura의 X-선학적 연구 (RADIOLOGIC STUDY ON LAMINA DURA)

  • 안형규
    • 치과방사선
    • /
    • 제11권1호
    • /
    • pp.67-74
    • /
    • 1981
  • The study was performed to investigae the thickness of lamina dura of the human teeth in periodontal disease, which obtained from the intraoral roentgenograms of the 122 cases taken by bisecting technic. All films were divided into the different ages, the different sexes, and the different location of the different teeth. The obtained results were as follows: 1. Compared with the normal teeth, the thickness of lamina dura in periodontal disease is in creased in all of different ages, sexes and teeth. (equation omitted) 2. Generally, the alveolar crest portion is the thickest among the root surfaces, and midroot, apex followed, and the average thinckness of the posterior teeth is thicker than that of anterior teeth. The mean value of the whole maxillary teeth is almost same as that of mandibular teeth. On the whole cases, the differences of male and female is about 0.01㎜, which is not a significant differences.

  • PDF