• Title/Summary/Keyword: Difference tomography

Search Result 827, Processing Time 0.029 seconds

Effect of Clinical Improvement of Schizophrenic Symptoms on $^{99m}Tc$-HMPAO Brain SPECT (정신분열병 환자의 임상적 증세 호전에 따른 $^{99m}Tc$-HMPAO 뇌 SPECT 소견의 변화)

  • Shin, Chul-Jin;Koong, Sung-Soo;Chung, In-Won
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.310-319
    • /
    • 1997
  • This study investigated regional blood flow changes of frontal, temporal, and basal ganglia in eleven schizophrenic patients on DSM-IV criteria to examine the relationship between rCBF and clinical improvement of symptoms. Single-photon emission computed tomography imaging with $^{99m}Tc$-HMPAO was peformed in baseline and sixth weeks after the treatment, and concurrently psychopathology was assessed by PANSS. Antipsychotics wash-out period was more than 2 weeks, and three patient were drug naive. All patients were finally divided into two groups, the improved or not improved. We examined the difference of the amount of rCBF changes between two groups. Finally, frontal activity shows no significant difference between two groups but both groups show decreased frontal blood flow after antipsychotic treatment. However, the change of right temporal rCBF had positive correlation with the change of the total PANSS score, and the change of left temporal lobe activity was greater in the improved group than in the not improved group. Our results suggest that the temporal lobe activity has relation to the underlying schizophrenic symptoms.

  • PDF

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Accuracy of simulation surgery of Le Fort I osteotomy using optoelectronic tracking navigation system (광학추적항법장치를 이용한 르포씨 제1형 골절단 가상 수술의 정확성에 대한 연구)

  • Bu, Yeon-Ji;Kim, Soung-Min;Kim, Ji-Youn;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.114-121
    • /
    • 2011
  • Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint, using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3 points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1) Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system I s relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

Relation of Bony Carotid Canal Diameter and Clinical Manifestations in Patients with Moyamoya Disease (모야모야병 환자의 뼈목동맥관 직경과 임상표현과의 관계)

  • Ahn, So Hyun;Song, Hong-ki;Kim, Cheol Ho;Jang, Min Uk;Sohn, Jong-Hee;Choi, Hui Chul
    • Annals of Clinical Neurophysiology
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Background: Moyamoya disease is characterized by a progressive stenosis or occlusion of the intracranial internal carotid artery and/or the proximal portion of the anterior cerebral artery and middle cerebral artery. Whether the onset time was childhood or adulthood, the bony carotid canal diameter might be different, but reflects the size of internal carotid artery passing through the bony carotid canal. In this study, we aimed to identify the relationship between bony carotid canal diameter and clinical manifestation. Methods: 146 consecutive patients diagnosed with moyamoya disease by brain imaging studies were included. We measured the diameter of a transverse portion of bony carotid canal on bone window of a brain computed tomography(CT) image. Patients were divided into two groups, ischemic or hemorrhagic stroke according to clinical manifestation. As a result, 115 patients were included. The Suzuki stage was used as criteria for disease progression. Results: Bony carotid canal diameter was $3.6{\pm}0.5$ (right) and $3.6{\pm}0.4$ (left) in the hemorrhagic stroke group, and $3.7{\pm}0.4$ (right) and $3.6{\pm}0.4$ (left) in the ischemic stroke group. The bony carotid canal diameter of the moyamoya vessels (3.6 mm) was smaller than the diameter of non-moyamoya vessels (3.8 mm), significantly (p = 0.042). However, there was no difference in the collateral patterns and clinical manifestation in a comparison of both groups. Conclusions: In our study, there was no significant difference of clinical manifestations and collateral patterns depend on the bony carotid canal diameter in patients with moyamoya disease. These findings suggest that the clinical presentations of moyamoya disease are not related to the onset time of the disease.

The Effect of Porcine Cancellous Bone for Bone Regeneration and Application of Platelet-rich Fibrin in Rabbit Calvarial Defect (가토 두개골 결손부에 이식된 저골(猪骨)과 혈소판 풍부 섬유소의 골형성 효과)

  • Park, Jeong Ik;Jeon, Seong Bae;Song, Young Il;Do, Hyung Sik;Lee, Jin Yong;Jang, Hyun Seok;Kwon, Jong Jin;Rim, Jae Suk;Lee, Eui Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.391-397
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the effectiveness of the platelet-rich fibrin (PRF) used in combination with the porcine cancellous bone as a scaffold, in promoting bone regeneration in the bone defects ofthe rabbit calvaria. Methods: Ten rabbits were used in the study. Three round-shaped defects (diameter 8.0 mm) were created in the rabbit calvaria and were filled with nothing (control group), porcine cancellousbone (Experimental Group 1, porcine bone) and PRF-mixed porcine cancellous bone (Experimental Group 2). TS-GBB is a xenogenic bone-substitute product comprised of a high heat-treated mineralized porcine cancellous bone. Animals were sacrificed at 6 weeks and 12 weeks for the histological and radiographic evaluations. Results: In the micro computed tomography and histological results, the experimental groups 1 and 2 showed more bone formation, remodeling, and calcification than the control group. The new bone formation ratio showed theGroup 2 to be larger than Group 1 at6 and 12 weeks. However, there was no significant difference between the experimental groups 1 and 2 in the new bone formation area, at the 6 and 12 weeks (P>0.05). Conclusion: The PRF-mixed group showed more bone formation than the porcine cancellousbonegroup (TS-GBB), butthere was a no significant difference. The PRF may not lead to enhanced bone healing when grafted with the porcine cancellous bone.

Evaluation of the mechanical properties and clinical efficacy of biphasic calcium phosphate-added collagen membrane in ridge preservation

  • Lee, Jung-Tae;Lee, Yoonsub;Lee, Dajung;Choi, Yusang;Park, Jinyoung;Kim, Sungtae
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.238-250
    • /
    • 2020
  • Purpose: This study aimed to evaluate the biocompatibility and the mechanical properties of ultraviolet (UV) cross-linked and biphasic calcium phosphate (BCP)-added collagen membranes and to compare the clinical results of ridge preservation to those obtained using chemically cross-linked collagen membranes. Methods: The study comprised an in vitro test and a clinical trial for membrane evaluation. BCP-added collagen membranes with UV cross-linking were prepared. In the in vitro test, scanning electron microscopy, a collagenase assay, and a tensile strength test were performed. The clinical trial involved 14 patients undergoing a ridge preservation procedure. All participants were randomly divided into the test group, which received UV cross-linked membranes (n=7), and the control group, which received chemically cross-linked membranes (n=7). BCP bone substitutes were used for both the test group and the control group. Cone-beam computed tomography (CBCT) scans were performed and alginate impressions were taken 1 week and 3 months after surgery. The casts were scanned via an optical scanner to measure the volumetric changes. The results were analyzed using the nonparametric Mann-Whitney U test. Results: The fastest degradation rate was found in the collagen membranes without the addition of BCP. The highest enzyme resistance and the highest tensile strength were found when the collagen-to-BCP ratio was 1:1. There was no significant difference in dimensional changes in the 3-dimensional modeling or CBCT scans between the test and control groups in the clinical trial (P>0.05). Conclusions: The addition of BCP and UV cross-linking improved the biocompatibility and the mechanical strength of the membranes. Within the limits of the clinical trial, the sites grafted using BCP in combination with UV cross-linked and BCP-added collagen membranes (test group) did not show any statistically significant difference in terms of dimensional change compared with the control group.

The Analysis of Cerebral Aneurysm's Prone position Using Computed Tomography Equipment (전산화단층촬영장치를 이용한 뇌동맥류의 호발부위 분석)

  • Lee, Seon-Tae;Lim, Jong-Soo;Park, Jeong-Kyu
    • Journal of Digital Contents Society
    • /
    • v.12 no.3
    • /
    • pp.271-277
    • /
    • 2011
  • This research studied 249 patients who has an aneurysm and went through computerized CT angiography at S University Hospital in Northern Kyung-sang area from October 1st 2008 to September 30th 2010, and the results are the following. Among total 249 of research objects, 159 women (63.9%) showed higher distribution than 90 men (36.1%) The order of the distribution of aneurysm classified by blood vessel is the following. Posterior communicating artery 34.9% as the highest, internal carotid artery 21.7%, middle cerebral artery of 15.7%, anterior communicating artery 14.5%, posterior cerebral artery and posterior cerebral artery channel 3.6% each, anterior cerebral artery and vertebral artery 2.4% each, and posterior inferior cerebellar artery 1.2%. As a result of analysis of distribution of aneurysm classified by gender, there was no case of posterior cerebral artery and posterior cerebral artery channel among men, and there was no case of posterior inferior cerebellar artery among women. Distribution of aneurysm classified by vessel according to gender showed no statistic significance. (p<0.05). And distribution of aneurysm classified by vessel according to the age, showed no statistic significance. (p>0.05), After applying post analysis to understand the group with age difference, the significance was the highest among the group of 61-70, (4.21), and the group of the age under 30 was the lowest. (2.0) There was statistic significance on the distribution of aneurysm classified by vessel according to the season. (p<0.05). After applying post-analysis in order to understand the groups with difference between seasons, it was found that fall was the highest (4.55) and spring was the lowest. (2.50)

A study on Radix Entomolaris about prevalence and correlation of canal orifices location according to number of roots in mandibular first molars (하악 제1대구치에서 Radix Entomolaris의 발현빈도와 치근의 개수에 따른 근관 입구들 사이의 위치 관계에 대한 연구)

  • Jang, Ji-Hye;Kim, Jin-Woo;Cho, Kyung-Mo;Kim, Soo-Yeon;Park, Se-Hee
    • The Journal of the Korean dental association
    • /
    • v.56 no.12
    • /
    • pp.695-706
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the ratio of 4 root canals and the incidence of Radix Entomolaris in mandibular first molars and find out anatomical difference according to number of roots by analysis of cone-beam CT images in a Korean population. Materials and Methods: Total 142 images containing mandibular first molars were selected from CBCT images taken from 2013 to 2017 at Gangneung-Wonju National University Dental Hospital. After reconstructing the image with reference to the Cemento-enamel junction, the root canals were detected at the bottom of the pulpal floor and the number of roots and root canals were analyzed. Various lengths and MLO-DLO-DBO angle were measured between each canal orifices and the external contour line of the tooth, and the distolingual canal wall thickness was measured. Student t-test was used for statistical significance. Results: Among the total 142 teeth, 4 canals were 42.2% and Radix Entomolaris was 25.3%. As the results of measuring various lengths and the angle, the distolingual canal orifice in Group 2(with Radix Entomolaris) tends to deviate to the lingual side than the mesiolingual canal orifice and to the mesial side than the distobuccal canal orifice. Besides, thickness of the distolingual canal wall in Group 2(with Radix Entomolaris) was significantly thinner than that of Group 1 at every level except pulpal floor level. Conclusion: It is necessary to consider the difference according to the presence of Radix Entomolaris in endodontic treatment.

  • PDF

Study on the Contrast Media Volume according to Scan Time during Brain Angiography Examination (Brain Angiography 검사 시 Scan Time에 따른 Contrast Media Volume에 대한 연구)

  • Lee, Ju Ryeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.29-35
    • /
    • 2021
  • The purpose of this study was to investigate whether there is a difference in image quality before and after reducing the amount of contrast medium in cerebral hemorrhagic patients who periodically follow up CT, and after reducing the amount of contrast medium, the image before and after reduction was examined, and the image quality was assessed by setting ROI at each vessel location using MMWP program. First Rt. CCA, Lt.CCA. Rt.MCA, Lt.MCA and Basilar Artery each got an ROI. Second, the mean and standard deviation values for the ROI were obtained. Third, SNR and CNR were obtained through the average and standard deviation values obtained. T-test statistics show that the SNR and CNR values obtained show that the result values for SNR are Rt.CCA 0.765, Ltd.CCA 0.871, Rt.MCA 0.343 LT.MCA 0.235, Basilar alternative 0.916, result value for CNR Rt.CCA 0.088, Ltd.CCA 0.069, Rt.MCA 0.818, Let's...MCA 0.579 and Basilar Artery 0.878. The results obtained through the obtained SNR and CNR values showed no difference in the quality of the images before and after reducing contrast medium. Therefore, we hope that this study will be an indicator that reduces the burden on contrast agents on patients who do CT examinations periodically.