• Title/Summary/Keyword: Difference tomography

Search Result 756, Processing Time 0.022 seconds

Cone-beam computed tomography characterization of the intraosseous vascular canal in the lateral wall of the maxillary antrum

  • Shetty, Shishir Ram;Al Bayatti, Saad Wahby;Marei, Hesham;Shetty, Raghavendra;Abdelmagyd, Hossam Abdelatty;Luke, Alexander Maniangat
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.1
    • /
    • pp.34-39
    • /
    • 2021
  • Objectives: The purpose of the study was to assess the occurrence, location, and dimensions of the intraosseous vascular canal in the lateral wall of the maxillary antrum using cone-beam computed tomography (CBCT). Materials and Methods: In this retrospective study, we examined 400 CBCT scans from our archive of patients who had earlier reported to a dental teaching hospital in the United Arab Emirates. The prevalence, location, and dimensions of the lateral antral intraosseous canal (LAIC) in the maxillary antrum were evaluated by 2 examiners using standardised methods. A third examiner was consulted in cases of disagreement. Results: The prevalence of LAIC was 62.3% (249 maxillary antra) among the study population. The mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC in the posterior maxillary region was 19.83±3.12 mm. There was a significant difference (P=0.05) between the maxillary molar and premolar regions in mean distance from the most inferior point of the alveolar bone and the inferior border of the LAIC. There was no statistically significant difference in mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC between dentulous and edentulous areas (P=0.1). The G3-intrasinusal type canal less than 1mm in diameter was the most common type of LAIC. Conclusion: This study established the approximate location of the LAIC in a United Arab Emirates cohort, which will assist the oral surgeon in selecting the appropriate site for sinus lift procedures with reduced risk of surgical hemorrhage.

Cone-beam computed tomography texture analysis can help differentiate odontogenic and non-odontogenic maxillary sinusitis

  • Andre Luiz Ferreira Costa;Karolina Aparecida Castilho Fardim;Isabela Teixeira Ribeiro;Maria Aparecida Neves Jardini;Paulo Henrique Braz-Silva;Kaan Orhan;Sergio Lucio Pereira de Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: This study aimed to assess texture analysis(TA) of cone-beam computed tomography (CBCT) images as a quantitative tool for the differential diagnosis of odontogenic and non-odontogenic maxillary sinusitis(OS and NOS, respectively). Materials and Methods: CBCT images of 40 patients diagnosed with OS (N=20) and NOS (N=20) were evaluated. The gray level co-occurrence (GLCM) matrix parameters, and gray level run length matrix texture (GLRLM) parameters were extracted using manually placed regions of interest on lesion images. Seven texture parameters were calculated using GLCM and 4 parameters using GLRLM. The Mann-Whitney test was used for comparisons between the groups, and the Levene test was performed to confirm the homogeneity of variance (α=5%). Results: The results showed statistically significant differences(P<0.05) between the OS and NOS patients regarding 3 TA parameters. NOS patients presented higher values for contrast, while OS patients presented higher values for correlation and inverse difference moment. Greater textural homogeneity was observed in the OS patients than in the NOS patients, with statistically significant differences in standard deviations between the groups for correlation, sum of squares, sum of entropy, and entropy. Conclusion: TA enabled quantitative differentiation between OS and NOS on CBCT images by using the parameters of contrast, correlation, and inverse difference moment.

Phase boundary estimation with effective initial guess in electrical impedance tomography (전기 임피던스 단층촬영 기법에서 효과적인 초기치 설정을 통한 상 경계 추정)

  • Kim, Bong-Seok;Kim, Sin;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2012
  • In the phase boundary estimation problem, the estimation performance depends on the initial guess. However, there is no information on the number of bubbles and those positions for the initial guess in real flows. Therefore, it is very important to set appropriate initial guesses from prior information. In this paper, in order to set initial guesses for estimating the phase boundaries in two-phase flows, first, unknown resistivity distribution was estimated using the difference reconstruction method. After that, an adaptive threshold value was automatically computed using intermodes method. Based on this value, the number of bubbles and the initial position were determined. The numerical experiments have been performed to evaluate the estimation performance of the proposed method.

Analysis of SAR in a Human Head for a Cellular Phone (셀룰라 휴대폰에 의한 인체 두부의 SAR 해석)

  • 이애경;최형도;김진석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.6
    • /
    • pp.776-787
    • /
    • 1998
  • This paper analyzes the local specific absorption rates (SAR's) averaged over 1 g and 10 g in a human head model in contact with a mobile phone operating at 835 MHz. The used numerical method is a total field finite-difference time-domain (FDTD) technique. The phone was simulated with a conducting box, a plastic case, and a whip antennal composed of a monopole and a helix. The discrete human model of the spatial resolution 3 mm is based on Magnetic Resonance Imaging (MRI), computerized tomography (CT) and anatomical images. The near field and far field and far field patterns were analyzed for extended and retracted phone. The two methods to take the volumes of the weights, 1 g or 10 g in tissue are proposed and compared to offer a reproductive technique for SAR estimations.

  • PDF

Metal artifact production and reduction in CBCT with different numbers of basis images

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Groppo, Francisco Carlos;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.41-44
    • /
    • 2018
  • Purpose: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. Results: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). Conclusion: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

A Study on the Adequacy Awareness of Computed Tomography Equipment Quality Control (전산화단층촬영장비 정도관리의 적정 인지도에 관한 연구)

  • Kim, Gyoo Hyung;Lim, Cheong Hwan;Kim, Ki Jeong
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • Investigate the adequacy awareness of accuracy control of CT apparatus Questionnaire survey and statistical analysis in the analysis according to age, there is a difference between familiarity with accuracy management items (F = 14.187, p<0.001) and necessity of accuracy control (F=8.109, p<0.001), depending on academic background and work history, There is a difference only in familiarity (F=5.103, p<0.05, F=13.394, p<0.001), and according to the scale of the medical institution analysis shows that if you are more interested than senior general hospital grade hospital grade or less It was analyzed. In order to advance the accuracy control level, we have introduced our comprehensive and efficient comprehensive and efficient integrated medical image quality management operation system of the whole medical image equipment including CT device, It is thought that it is necessary to develop human resources capable of doing.

Indications for Laparotomy in Patients with Abdominal Penetrating Injuries Presenting with Ambiguous Computed Tomography Findings

  • Choi, Eun Ji;Choi, Sanghee;Kang, Byung Hee
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.112-118
    • /
    • 2021
  • Purpose: Negative laparotomy in patients with abdominal penetrating injuries (APIs) is associated with deleterious outcomes and unnecessary expense; however, the indications for laparotomy in hemodynamically stable patients with ambiguous computed tomography (CT) findings remain unclear. This study aimed to identify the factors associated with negative laparotomy. findings Methods: Data of patients who underwent laparotomy for APIs between 2011 and 2019 were retrospectively reviewed. Patients who presented with definite indications for laparotomy were excluded. The patients were dichotomized into negative and positive laparotomy groups, and the baseline characteristics, laboratory test results, and CT findings were compared between the groups. Results: Of 55 patients with ambiguous CT findings, 38 and 17 patients were assigned to the negative and positive laparotomy groups, respectively. There was no significant difference between the groups with respect to the baseline characteristics or the nature of the ambiguous CT findings. However, the laboratory test results showed that there was a difference in the percentage of neutrophils between the groups (negative: 55.6% [range 47.4-66.1%] vs. positive: 79.8% [range 77.6-88.2%], p<0.001), although the total white blood cell count was not significantly different. The mean duration of hospital stay for the negative laparotomy group was 13.1 days, and seven patients (18.4%) experienced complications. Conclusions: Diagnostic factors definitively indicative of laparotomy were not identified, although the percentage of neutrophils might be helpful. However, routine laparotomy in patients with peritoneal injuries could result in instances of negative laparotomy.

The effect of different confluence confirmation strategies on the obturation of Vertucci type II canal: micro-CT analysis

  • Seungjae Do ;Min-Seock Seo
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.12.1-12.9
    • /
    • 2021
  • Objectives: The present study aims to compare the obturation quality of 2 confluence confirmation techniques in artificial maxillary first premolars showing Vertucci type II root canal configuration. Materials and Methods: Thirty artificial maxillary premolars having Vertucci type II root canal configuration were made. They were divided into 3 groups according to the confluence confirmation technique as follows. Gutta-percha indentation (GPI) group (confluence confirmation using a gutta-percha cone and a K file); electronic apex locator (EAL) group (confluence confirmation using K files and EAL); and no confluence detection (NCD) group. In the GPI group and the EAL group, shaping and obturation were performed with the modified working length (WL). In the NCD group, shaping was performed without WL adjustment and obturation was carried out with an adjusted master cone. Micro-computed tomography was used before preparation and after obturation to calculate the percentage of gutta-percha occupied volume (%GPv) and the volume increase in the apical 4 mm. Data were analyzed using 1-way analysis of variance and post hoc Tukey's test. Results: Statistically significant difference was not found in terms of the %GPv from the apex to apical 4 mm. However, the NCD group showed a statistically significant volume increase compared with the EAL group (p < 0.05). Conclusions: In terms of gutta-percha occupied volume, no significant difference was observed among the 3 groups. Confluence confirmation using an EAL in teeth with Vertucci type II configuration showed less volume increase during canal shaping compared with no confluence confirmation.

Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model (CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Um Ki-Doo;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

Obesity Estimation of Abdominal Fat by Using Computed Tomography : Influence of Breathing Motion on The Fat Measurement (전산화단층영상을 이용한 복부 지방 계측법에서 호흡운동이 비만도 측정에 미치는 영향)

  • Seoung, Youl-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • The purpose of this study was to evaluate how much effect to accuracy when measuring abdominal fat by Computed Tomography (CT) under different respiration movements. The study volunteer composed of 66 normal adults ($50.4{\pm}11.2$ years, 33 males, 33 females). We measured their obesity by using Broca index, body mass index (BMI) and CT and have investigated the correlation. The CT scanning for the obesity measurement have done in two ways, one was done in stopping breath after exhaling and the other was holding a breath after inhaling. The results showed no statistically significant difference among the three measuring techniques. And, the error in two ways of inhaling and exhaling was showed 24.2% of volunteers. The two ways of respiration movements made different result in visceral fat area (P = 0.044), subcutaneous fat area (P = 0.636) and abdominal obesity value (P = 0.012). This study demonstrates that the two ways of respiration movements when scanning CT makes change in accuracy in visceral fat area, and in abdominal obesity quantitative measure. Therefore, our study suggests that CT should take twice in two ways while a patient stops breath after exhaling and holds a breath after inhaling when measuring abdominal obesity using CT equipments.