• Title/Summary/Keyword: Difference tomography

Search Result 778, Processing Time 0.033 seconds

Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom (호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교)

  • Kim, Seong-Eun;Won, Hui-Su;Hong, Joo-Wan;Chang, Nam-Jun;Jung, Woo-Hyun;Choi, Byeong-Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Purpose : The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. Materials and Methods : The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Results : Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54~2.33, 5.16~8.06, 9.03~20.11 ml in MIP, respectively, 0.00~1.48, 0.00~8.47, 1.42~24.85 ml in MinIP, respectively and 0.00~1.17, 0.00~2.19, 0.04~3.35 ml in AVG, respectively. Conclusion : After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  • PDF

Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images

  • Kim, Hyungsuk;Yoo, Chang Hyun;Park, Soo Bin;Song, Hyun Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.2
    • /
    • pp.71-79
    • /
    • 2020
  • Background: The glenoid version of the shoulder joint correlates with the stability of the glenohumeral joint and the clinical results of total shoulder arthroplasty. We sought to analyze and compare the glenoid version measured by traditional axial two-dimensional (2D) computed tomography (CT) and three-dimensional (3D) reconstructed images at different levels. Methods: A total of 30 cases, including 15 male and 15 female patients, who underwent 3D shoulder CT imaging was randomly selected and matched by sex consecutively at one hospital. The angular difference between the scapular body axis and 2D CT slice axis was measured. The glenoid version was assessed at three levels (midpoint, upper one-third, and center of the lower circle of the glenoid) using Friedman's method in the axial plane with 2D CT images and at the same level of three different transverse planes using a 3D reconstructed image. Results: The mean difference between the scapular body axis on the 3D reconstructed image and the 2D CT slice axis was 38.4°. At the level of the midpoint of the glenoid, the measurements were 1.7°±4.9° on the 2D CT images and -1.8°±4.1° in the 3D reconstructed image. At the level of the center of the lower circle, the measurements were 2.7°±5.2° on the 2D CT images and -0.5°±4.8° in the 3D reconstructed image. A statistically significant difference was found between the 2D CT and 3D reconstructed images at all three levels. Conclusions: The glenoid version is measured differently between axial 2D CT and 3D reconstructed images at three levels. Use of 3D reconstructed imaging can provide a more accurate glenoid version profile relative to 2D CT. The glenoid version is measured differently at different levels.

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

Statistical Characteristics of Polarization - Sensitive Optical Coherence Tomography for Tissue Imaging

  • Oh, Jung-Taek;Kim, Beop-Min;Kim, Seung-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.211-215
    • /
    • 2003
  • Statistical characteristics of the backscattered light from turbid tissues obtained by polarizationsensitive optical coherence tomography are investigated. The amplitude of the backscattered light is found to faithfully follow the Rayleigh distribution predicted by the scattering theory of electromagnetic waves in random media. The probability density function of the phase difference between the two orthogonal polarization components of the backscattered light is explicitly derived and then verified in comparison with the experimental data measured from in-vitro tissues of porcine ligament.

An Elementary Study on the Combustion Mechanism of Levitated Droplet Clusters by Ultrasonic Wave (초음파를 이용한 부상유적군의 연소기구에 관한 기초연구)

  • Jung, Jin-Do;Kim, Seung-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1191-1199
    • /
    • 2003
  • This paper describes to observe the combustion process of only one droplet cluster. In this study, liquid fuel was atomized by ultrasonic wave to form an acoustically levitated droplet cluster. In order to elucidate the detailed structure of burning process of the droplet cluster, laser tomography method was applied. Time-series planar images of fuel droplets were processed and diameter of the each droplet was calculated based on the Mie-scattering theory. Using these data, the modified droplet group combustion number was estimated in time-series. As the result, when the internal droplet group combustion occur, the modified group combustion number dose not decrease monotonically, but show a tow-staged decreasing process. In all case of combustion process, combustion reactions were measured two types that combustion speed was fast and slow. It was casued by difference of concentration degree and droplet size distribution.

An Experimental Study on the Turbulent Combustion Characteristics of Hydrocarbon Mixtures by Hydrogen Addition (수소를 첨가한 탄화수소 혼합기의 난류연소 특성에 관한 실험적 연구)

  • 김준효;한원희;키도히로유끼
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.6
    • /
    • pp.65-72
    • /
    • 2003
  • In order to clarify turbulent combustion characteristics of hydrocarbon mixtures by hydrogen addition, turbulent burning velocities in a constant volume vessel were measured for both lean and rich hydrocarbon mixtures. Moreover, the configuration characteristics of turbulent flame was investigated in the wrinkled laminar flame region. A laser tomography technique was used to obtain the images of turbulent flame, and quantitative analyses were performed. As a result, the characteristics of turbulent burning velocity was shown a distinct difference with the addition rate of hydrogen between lean and rich mixtures. On the other hand, the obtained tomograms showed that the surface area of turbulent flame depends almost only on the turbulence intensity.

A Study on Spinal Bone Mineral Density Measured with Quantitative Computed Tomography (정량적 전산화 단층촬영법을 이용한 척추 골밀도 측정)

  • Yeo, Jin-Dong;Park, Jae-Seong
    • The Korean Journal of Health Service Management
    • /
    • v.3 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • The purpose of this study is to evaluate the relationship between osteoporotic postmenopausal women and its bone mineral density value by using the single energy quantitative CT. 1. Decreasing BMD with age is evident. There is a significant low BMD value in the osteoporotic women compared with the healthy subgroup. 2. BMD decrease from T12 to L4, except in healthy premenopausal women. 3. Relationship of spinal BMD expressed as average BMD of T12 through L4 Show strong correlation with mean BMD in all vertebral levels. 4. There are significantly different BMD value from T12 through L4 in subgroup 1, 2, 3 but there is no statistically significant difference between subgroup 2 and 3. Conclusion, There is a significant decreasing BMD with age but it is difficult to differentiate postmenopausal relatively healthy women from osteoporotic women by BMD.

  • PDF

The Comparative Analysis of Chest Radiographs and Low Dose Computed Tomography in Subjects for Health Screening (건강검진 수검자를 대상으로 한 단순흉부촬영과 저 선량 나선형 CT와의 비교 분석)

  • Choi Jin Yeong;Kang Hwa Won;Lee Kang Woo;Lee Woo Sik
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.112-119
    • /
    • 2002
  • Purpose : The purpose of this study is to evaluate the usefulness, after we compare and analyze the difference about the location of a lesion and the result of diagnosis on chest radiographs(CR) and low dose computed tomography(LDCT) in subjects for healt

  • PDF

Comparative Study for the Measurement of Fermoral Anteversion by Manual Method and Image Viewer (대퇴골 전염각 측정을 위한 수 작업 방법과 Image Viewer 방법과의 비교 연구)

  • Gwon, Dae-Cheol;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • The measurement of the fermoral anteversion is an important factor in the practice of orthopedic surgery. The anteversion is measured by means of the axis of head and neck of the femur. In this study. widely used computed tomography method of measuring anteversion was tested on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In January and February 2001, 30 patients 3 to 6 years of age were randomly selected from Seoul National University Hospital. the purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing image viewer program. This new method was more accurate and convenient than the conventional manual method. No significant difference was observed between the manual method and the image viewer measurement of femoral anteversion. In conclusion, image viewer program was statistically more reliable in determining the angle of the fermoral anteversion.

  • PDF

MULTI-WAVELENGTH FIBRIL DYNAMICS AND OSCILLATIONS ABOVE SUNSPOT WAVE PROPAGATION

  • MUMPUNI, EMANUEL S.;HERDIWIJAYA, DHANI;DJAMAL, MITRA;DJAMALUDDIN, THOMAS
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.59-60
    • /
    • 2015
  • High resolution, multi-wavelength images from the Dutch Open Telescope were used to study the detailed mechanisms that might be involved in the multiple layer solar atmosphere observed in high cadence multi-wavelength observations. With the exceptional data observed for active region NOAA 10789 on 2005 July 13th, we study the changing pattern of the fibril using multi-wavelength tomography of the $H{\alpha}$ line center and blue wing, Ca II H, and the G Band. It is believed that a long fibril that is rooted in the umbra, with longer apparent periodicity, may be due to morphological changes. To determine this, we conduct phase difference and coherency analysis between points along the fibril to understand how the wave propagates.