Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy |
Kauweloa, Kevin I.
(Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego)
Park, Justin C. (Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego) Sandhu, Ajay (Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego) Pawlicki, Todd (Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego) Song, Bongyong (Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego) Song, William Y. (Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego) |
1 | Li T, Schreibmann E, Yang Y, et al: Motion correction for improved target localization with on-board cone-beam computed tomography. Phys Med Biol 51:253-267 (2006) DOI ScienceOn |
2 | Vedam SS, Keall PJ, Kini VR, et al: Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol 48(1):45-62 (2003) DOI ScienceOn |
3 | Lu W, Parikh PJ, Hubenschmidt JP, et al: A comparison between amplitude sorting and phase angle sorting using external respiratory measurement for 4DCT. Med Phys 33(8):2964-2974 (2006) DOI |
4 | Duggan DM, Ding GX, Coffey CW, et al: Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: Initial experience. Lung Cancer 56(1):77-88 (2007) DOI ScienceOn |
5 | Yin FF, Das S, Kirkpatrick J, et al: Physics and imaging for targeting of oligometastases. Semin Radiat Oncol 16(2):85-101 (2006) DOI ScienceOn |
6 | Vergalasova I, Maurer J, Yin FF: Potential underestimation of the internal target volume (ITV) from free-breathing CBCT. Med Phys 38(8):4689-4699 (2011) DOI ScienceOn |
7 | Buzug TM: Computed Tomography: From Photon Statistics to Modern Cone-Beam CT. 1st ed, Springer-Verlag Berlin, Heidelberg (2008) pp. 521 |
8 | Hsieh J: Computed Tomography: Principles, Design, Artifacts, and Recent Advances. 2nd ed, SPIE/John Wiley & Songs, Inc. (2009) pp. 556 |
9 | Li T, Xing L: Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy. Int J Radiat Oncol Biol Phys 67(4):1211-1219 (2007) DOI ScienceOn |
10 | Song WY, Kamath S, Ozawa S, et al: A dose comparison study between XVI and OBI CBCT systems. Med Phys 35(2):480-486 (2008) DOI ScienceOn |
11 | Sonke JJ, Zijp L, Remeijer P, et al: Respiratory correlated cone beam CT. Med Phys 32(4):1176-1186 (2005) DOI ScienceOn |
12 | Nakayama Y, Awai K, Funama Y, et al: Abdominal CT with low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise. Radiology 237(3):945-951 (2005) DOI ScienceOn |
13 | Low DA, Nystrom M, Kalinin F, et al: A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Med Phys 30(6):1254-1263 (2003) DOI ScienceOn |
14 | Fitzpatrick MJ, Starkschall G, Antolak JA: Displacementbased binning of time-dependent computed tomography image data sets. Med Phys 33(1):235-246 (2006). DOI |
15 | Ruan D, Fessler JA, Balter JM: Mean position tracking of respiratory motion. Med Phys 35(2):782-792 (2008) DOI ScienceOn |
16 | Underberg RW, Lagerwaard FJ, Cuijpers JP, et al: Fourdimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. Int J Radiat Oncol Biol Phys 60:1283-1290 (2004) DOI ScienceOn |
17 | Jin JY, Ajlouni M, Chen Q, et al: A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy. Radiother Oncol 78:177-184 (2006) DOI ScienceOn |
18 | Purdie TG, Bissonnette JP, Franks K, et al: Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position. Int J Radiat Oncol Biol Phys 68(1):243-252 (2007) DOI ScienceOn |
19 | Yeung AR, Li JG, Shi W, et al: Tumor localization using cone-beam CT reduces setup margins in conventionally fractionated radiotherapy for lung tumors. Int J Radiat Oncol Biol Phys 74(4):1100-1107 (2009) DOI ScienceOn |
20 | Grills IS, Hugo G, Kestin LL, et al: Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy. Int J Radiat Oncol Biol Phys 70(4):1045-1056 (2008) DOI ScienceOn |
21 | Yin FF, Wang Z, Yoo S, et al: Integration of cone-beam CT in stereotactic body radiation therapy. Technol Cancer Res Treat 7(2):133-139 (2008) DOI |
22 | Yin FF, Wang Z, Yoo S, et al: In-room radiographic imaging for localization. Proceedings AAPM Summer School Integrating New Technologies into the Clinic: Monte Carlo and Image Guided Radiation Therapy. 2006, Ontario, Canada |
23 | Thilmann C, Nill S, Tucking T, et al: Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences. Radiother Oncol 1:16 (2006) DOI |
24 | Hsieh J: Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. Med Phys 25(11):2139-2147 (1998) DOI ScienceOn |
25 | Wink NM, Panknin C, Soldberg TD: Phase versus amplitude sorting of 4D-CT data. J Appl Clin Med Phys 7(1):77-85 (2006) DOI ScienceOn |
26 | Keall PJ: 4-Dimensional computed tomography imaging and treatment planning. Semin Radiat Oncol 14(1):81-90 (2004) DOI ScienceOn |
![]() |