• Title/Summary/Keyword: Difference spectra

Search Result 311, Processing Time 0.026 seconds

On the Suitability of Centered and Upwind-Biased Compact Difference Schemes for Large Eddy Smulations (II) - Static Error Analysis - (LES에서 중심 및 상류 컴팩트 차분기법의 적합성에 관하여 (II) - 정적 오차 해석 -)

  • Park, No-Ma;Yoo, Jung-Yul;Choi, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.984-994
    • /
    • 2003
  • The suitability of high-order accurate, centered and upwind-biased compact difference schemes for large eddy simulation is evaluated by a spectral, static error analysis. To investigate the effect of numerical dissipation on LES solutions, power spectra of discretization errors are evaluated for isotropic turbulence models in both continuous and discrete wavevector spaces. Contrary to the common belief, the aliasing errors from upwind-biased schemes are larger than those from comparable non-dissipative schemes. However, this result is the direct consequence of the definition of the power spectral density of the aliasing error, which poses the limitation of the static error analysis for upwind schemes.

Optimization for Arrayed Waveguide Grating having MMI Coupler for Flattened Transfer Function

  • Jung, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.169-173
    • /
    • 2006
  • This paper describes an efficient optimal design method for an arrayed waveguide grating (AWG) having MMI coupler with flattened transfer function. The objective function is the norm of the difference between calculated and target spectra. To analyze the AWG transfer function, the Fresnel-Kirchhof diffraction formula was employed and the design variable was optical path difference of each array waveguide. The (1+1) Evolution Strategy was applied to an eight-channel coarse wavelength division multiplexing (CWDM) AWG as the optimization tool. For obtaining a broadened spectrum, we use a MMI coupler and the variation in optical path difference at each array waveguide changes the shape of the transfer function to obtain the optimal spectrum shape.

EVALUATION OF NON-INVASIVE BLOOD GLUCOSE MEASUREMENT USING THREE TYPES OF NEAR INFRARED SPECTROMETER

  • Baek, Ju-Hyun;Kang, Na-Roo;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.289.1-289.1
    • /
    • 2003
  • Three types of near infrared spectrometer, a photo diode array type, a dispersive type and a FT type, were evaluated and compared the systematic difference in blood glucose measurement. The fundamental study was performed by adding glucose to buffer solution and bovine blood as the preceding study of non-invasive blood glucose. Spectra were collected using a 1.0 mm optical pathlength quartz cell by transmittance method. (omitted)

  • PDF

The Study of Optical Biopsy‘s Usefulness in Radiotherapy (방사선 치료에서 광학적 생검의 유용성에 관한 연구)

  • ;;Muller M.G.,;Feld M.S.
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • The prior purpose of this study is to introduce a optical biopsy and evaluate whether the optical biopsy, real-time, non-invasive technique, is a reliable tool to assess response to radiotherapy Four healthy volunteers, and four patients with inflammatory conditions of the oral cavity participated on the study. was obtained from each person enrolled in the study. Using FastEEM(Ercited Emission Matrix) as a optical biopsy tool, normal and tumor spectra are taken from the normal and the tumor regions. And then second optical biopsy are taken from the tumor regions in 4 patients with time delay at 7days.. Using a diagnostic algorithm, made by Gillenwater based on spectra excited at 337nm The Optical Biopsy turned out to be more suited for tumor diagnostic resulting in significant difference fluorescence spectra. The fluorescence intensity of cancerous tissue showed a higher position. The second fluorescence intensity of optical biopsy of cancerous oral tissue has more smaller than the first result. I conclude that optical biopsy, which technique don't need to remove tissue sample from body, and is a real time , and non-invasive measurement is a reliable tool to access to radiotherapy because FastEEM can do measure the variation of the tissue composition chemical, biological, and morphological after radiotherapy. Based on the fluorescence spectrum are taken from the optical biopsy in normal and tumor spectra as well as tumor spectra after 7days.

  • PDF

Pycnometric and Spectroscopic Studies of Red Phosphors Ca2+(1-1.5x)WO4:Eu3+x and Ca2+(1-2x)WO4:Eu3+x,Na+x

  • Cho, Seon-Woog
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2769-2773
    • /
    • 2013
  • Red phosphors $Ca_{(1-1.5x)}Eu_xWO_4$ and $Ca_{(1-2x)}Eu^_xNa_xWO_4$ were synthesized with various concentrations x of $Eu^{3+}$ ions by using a solid-state reaction method. The crystal structure of the red phosphors were found to be a tetragonal scheelite structure with space group $I4_1/a$. X-ray diffraction (XRD) results show the (112) main diffraction peak centered at $2{\theta}=28.71^{\circ}$, and indicate that there is no basic structural deformation caused by the vacancies ${V_{Ca}}^{{\prime}{\prime}}$ or the $Eu^{3+}$ (and $Na^+$) ions in the host crystals. Densities of $Ca_{(1-1.5x)}Eu_xWO_4$ were measured on a (helium) gas pycnometer. Comparative results between the experimental and theoretical densities reveal that $Eu^{3+}$ (and $Na^+$) ions replace the $Ca^{2+}$ ions in the host $CaWO_4$. Also, the photoluminescence (PL) emission and photoluminescence excitation (PLE) spectra show the optical properties of trivalent $Eu^{3+}$ ions, not of divalent $Eu^{2+}$. Raman spectra exhibit that, without showing any difference before and after the doping of activators to the host material $CaWO_4$, all the gerade normal modes occur at the identical frequencies with the same shapes and weaker intensities after the substitution. However, the FT-IR spectra show that some of the ungerade normal modes have shifted positions and different shapes, caused by different masses of $Eu^{3+}$ ions (or $Na^+$ ions, or ${V_{Ca}}^{{\prime}{\prime}}$ vacancies) from $Ca^{2+}$.

Mössbauer and Infrared Absorption Spectroscopy of Tourmaline Minerals (전기석 광물의 뫼스바우어 및 적외선 흡수 분광학)

  • Kim, Hee Jong;Kim, Soo Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.105-115
    • /
    • 1993
  • $M{\ddot{o}}ssbauer$ and Infrared absorption spectra of the iron-bearing tourmaline minerals show that the ferrous and ferric ions occupy the Y and Z octahedral sites. The Fe ions are almost ferrous, predominantly partitioning into Y site and partly take in Z site. The $Fe^{2+}$ content of the Z sites in brownish black tourmaline minerals are higher than that in blue/green tourmaline minerals. Therefore, 720 nm peak of brownish black samples is broader than that of blue/green samples in optical spectra. All of the blue/green tourmaline minerals used in experiment have only $Fe^{2+}$ ion. The IR spectra of tourmaline depend on the cation environments around OH groups, as also evidenced by their chemical analyses. There appear no difference in IR spectrum between O(1)H and O(3)H binding characters in the heat-treated samples. But the characteristic $3565cm^{-1}$ peak appears in the ferrous hydroxyl bearing silicates, where dehydroxylation temperature for OH coordinated to $Fe^{2+}$ is $700{\sim}800^{\circ}C$.

  • PDF

Optical Characterization of Sensory Rhodopsin II Thin Films using a Near-field Scanning Microwave Microscope (근접장 마이크로파 현미경을 이용한 로돕신의 광학적 특성 연구)

  • Yu, Kyung-Son;Kim, Song-Hui;Yoon, Young-Woon;Lee, Kie-Jin;Lee, Jung-Ha;Choi, Ah-Reum;Jung, Kwang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.80-85
    • /
    • 2007
  • We report the electro-optical properties of the sensory rhodopsin II using a near-field scanning microwave microscope(NSMM). Rhodopsin was known as a photoreceptor pigment with a retinal as a chromophore via a protonated Schiff base and consists of seven ${\alpha}-helical$ transmembrane segments. The sensory rhodopsin II, expressing E. coli UT5600 with endogenous retinal biosynthesis system and purified with $Ni^{-2}-NTA$ affinity chromatography in the presence of 0.02 % DM (Dodecyl Maltoside) from Natronomonas pharaonis. We measured the absorption spectra and the transients difference of sensory rhodopsin II from Natronomonas pharaonis using a UV/VIS spectrophotometer with Nd-Yag Laser (532 nm). The absorption spectra of NpSR II showed a typical rhodopsin spectrum with a left shoulder region and the photointermediates spectra of NpSR II-ground state (${\lambda}max=498\;nm$), NpSR II-M state (${\lambda}max=390\;nm$), and NpSR II-O state (${\lambda}max=550\;nm$) during the photocycle. The observed photocycle reaction was confirmed by measuring the microwave reflection coefficient $S_{11}$ at an operating frequency of f=3.93-3.95 GHz and compared with the results of a photocycle of NpSR II.

A method of X-ray source spectrum estimation from transmission measurements based on compressed sensing

  • Liu, Bin;Yang, Hongrun;Lv, Huanwen;Li, Lan;Gao, Xilong;Zhu, Jianping;Jing, Futing
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1495-1502
    • /
    • 2020
  • A new method of X-ray source spectrum estimation based on compressed sensing is proposed in this paper. The algorithm K-SVD is applied for sparse representation. Nonnegative constraints are added by modifying the L1 reconstruction algorithm proposed by Rosset and Zhu. The estimation method is demonstrated on simulated spectra typical of mammography and CT. X-ray spectra are simulated with the Monte Carlo code Geant4. The proposed method is successfully applied to highly ill conditioned and under determined estimation problems with a good performance of suppressing noises. Results with acceptable accuracies (MSE < 5%) can be obtained with 10% Gaussian white noises added to the simulated experimental data. The biggest difference between the proposed method and the existing methods is that multiple prior knowledge of X-ray spectra can be included in one dictionary, which is meaningful for obtaining the true X-ray spectrum from the measurements.

Redox Property of Transition Metal Oxides in Catalytic Oxidation (TPR/TPO 실험기법을 이용한 전이금속산화물의 산화-환원 특성 연구)

  • Kim, Young-Ho;Lee, Ho-In
    • Applied Chemistry for Engineering
    • /
    • v.10 no.8
    • /
    • pp.1161-1168
    • /
    • 1999
  • The redox property of oxide materials of the 3rd period transition metals(Cr~Zn), V, Mo, and W was studied with temperature-programmed reduction/temperature-programmed oxidation(TPR/TPO) experiment. The peak temperatures of TPO spectra were equal to or lower than those of TPR spectra. And the peak shapes of TPO spectra were broader than those of TPR ones. The activation energies of TPR/TPO for the oxides of the 3rd period transition metals showed in the range of 33~149 kJ/mol, while for the oxides of V, Mo, and W, they showed relatively higher values. The change of activation energies of TPR/TPO with various metal oxides showed a similar trend to the change of their metal-oxygen bond strengths. The change of activation energies of o-xylene oxidation for various metal oxides was proportional to the difference (${\Delta}E_a$) between the activation energy of TPR and that of TPO. From these results, we concluded that the oxidation of o-xylene over various metal oxide catalysts follows the Mars-van Krevelen mechanism including the surface reduction-oxidation of the metal oxide itself.

  • PDF

Drug-Biomacromolecule Interaction VII

  • Kim, Chong-Kook;Yang, Ji-Sum;Lim, Yun-Su
    • Archives of Pharmacal Research
    • /
    • v.7 no.1
    • /
    • pp.11-15
    • /
    • 1984
  • Binding of sic cephalosporins (cefotaxime, cefuroxime, cafazoline, cephalothin, cephaloridine, cephacetrile) to human serum albumin was studied. Fluorescence probe technique and difference spectrophotometry were employed to evaluate the nature and degree of association of cephalosporin-albumin complex. 1-anilinonaphthalene-8-surfonate was used as the fluorescence probe, and 2-(4'-hydroxybenzeneazo)benzoic acid as the UV spectrophotometric probe. Competitive bindings between cephalosporins and probe were observed. For the binding of cephalosporins to human serum albumin, three binding sites were identified by fluorescence probe technique but four binding constants of cephalosporins to human serum albumin measured by fluorescence probe technique are higher than those meausred by UV spectrophotometry.

  • PDF