• 제목/요약/키워드: Difference operator

검색결과 284건 처리시간 0.028초

야산 기계화 개간공법에 관한 연구 -레이크 도저의 적정 이빨 간격의 선택과 발배근작업능률 시험(제1보)- (Research on Mechanized Upland Reclamation Works An Experiment for the Selection of Optimum Teeth Interval and the Analysis of Efficiency of Stumping and Root-Clearing Methods by Rake Dozer. (Report 1))

  • 류한열;정하우박승우
    • 한국농공학회지
    • /
    • 제17권3호
    • /
    • pp.3860-3871
    • /
    • 1975
  • This experiment was carried out to establish the mechanized methods in stumping and root-clearing, which were the most important works in the reclamation of sloping uplands. The determination of optimum teeth interval of rake blades and its operation methods to reduce the quantity of transported topsoil during the works, are the aims of this investigation. A newly designed rake blade, whose net teeth intervals could be regulated by three stages as 15cm, 25cm, and 35cm, was manufactured to attach to the bulldozer of 13ton. The experiments were carried out at Kilsang-Myon, Kwangwha-Gun, from Aug. 9 to Aug. 23, 1975. For each interval, 36 test plots of 50${\times}$10mn in size, which were regulated under three levels of land slopes of 10, 20, and 30% and two different tree stand density of high or medium values, were randomly chosen and arranged by two-replicated split-split plot design. Each stump classified by its diameter was stumped and cleared by the rake dozer to be related between diameter and stumping time. The results obtained in this experiment can be summarized as follows: 1. Stumping times for the diameters ranging from 6 to 18cm of stumps are almost the same and they are not varied by the difference of teeth intervals of rake dozer. 2. By back-ward stumping method, the number of stumps which can be stumped per hour ranges almost from 100 to 170, showing significant difference with respect to the teeth intervals. The working area is sharply varied with not only the stand density of stumps but the teeth intervals. 3. Optimum stumping distance for each teeth interval of rake dozer to minimize the quantity of transported topsoil are varied with such the rates as it is 15m or 20m for 15cm of teeth interval, but 25m for 25cm or 35cm, respectively. The clearing distance could be chosen almost double as long as the operating distance. 4. The working areas per hour of the simultaneous stumping and clearing methods are no significant difference among the various treatments of working conditions, but they are affected by the operating techniques. However, the influencing factors of the working conditions as classified before and the working directions are ranged from 10 to 15 per cent of total working area, respectively. 5. The residual rates of stumps which are not stumped by the rake dozer in each test plot are generally reduced as the teeth interval gets narrower, but there are no significant difference among them. The mean residual rates average to be about 4% for the simultaneous stumping and clearing method. The back-ward stumping method are recommended to be supervised and directed by more than one man, to show the operator where the stumps are located. 6. The results according to the stumping and clearing methods are summarized as Table IV-2. And the selection of working methods is recommended to follow as shown in Fig. IV-9 with respect to the stand density of the field. 7. Generally speaking, the narrower the teeth interval, the better become the working results, but the more the quantity of transported topsoil is increased. Therefore, it is recommended that the teeth interval should be reduced from the present distance of more than 30cm to 25cm or 15cm, by developing suitable working methods through more field works and experiments.

  • PDF

다기관 코호트 연구에서 경동맥 내막-중막 두께 측정의 측정자간 신뢰도 평가 (Inter-Rater Reliability of Carotid Intima-Media Thickness Measurements in a Multicenter Cohort Study)

  • Lee, Jung Hyun;Choi, Dong Phil;Shim, Jee-Seon;Kim, Dae Jung;Park, Sung-Ha;Kim, Hyeon Chang
    • Journal of health informatics and statistics
    • /
    • 제41권1호
    • /
    • pp.49-56
    • /
    • 2016
  • 목적: 경동맥 내막-중막 두께와 경동맥 경화반의 존재유무는 죽상동맥경화증의 임상 전단계를 나타내는 지표로 널리 사용되고 있다. 경동맥 내막-중막 두께를 측정할 때의 측정자 의존성 때문에, 다기관 연구에서는 경동맥 내막-중막 두께와 경화반 측정의 기관간 신뢰도를 확인하는 것이 중요하다. 이 연구의 목적은 심뇌혈관 및 대사질환원인 연구센터에 속해 있는 세 임상기관 사이의 경동맥 내막-중막 두께와 경화반 측정의 측정자간 신뢰도를 평가하는 것이다. 방법: 심뇌혈관 질환 과거력이 없는 사람 20명이 2014-2015년 사이에 이 연구에 참여하였고(연령 37-64세), 미리 정해진 프로토콜에 따라 연구참여자의 좌, 우 경동맥을 세 임상기관에서 반복적으로 측정하였다. 총 경동맥의 원위부에서 측정한 경동맥 내막-중막 두께의 최대값과 평균값을 기록하였다. 경동맥에서의 경화반 존재유무는 측정자에 의해 확인되었다. 경동맥 내막-중막 두께와 경화반 존재유무의 신뢰도를 급내상관계수와 카파 통계량을 통해 각각 평가하였다. 결과: 계산된 급내상관계수는 최대 경동맥 내막-중막 두께를 평가하였을 때 0.647이었고 (95% CI: 0.487-0.779), 평균 경동맥 내막-중막 두께를 평가하였을 때 0.758 (95% CI: 0.632-0.854) 이었다. Bland Altman plot에서, 관측치의 대부분은 평균의 차이에서 ${\pm}1.96$ 표준편차 사이에 분포하였다. 각 기관 사이의 경화반 존재유무에 대한 카파 통계량은 0.304 (기관 1과 2), 0.507 (기관 1과 3), 0.606 (기관 2와 3)이었다. 전반적인 일치를 평가하는 Fleiss카파값은 0.445였다. 결론: 세 임상기관 사이의 경동맥 내막-중막 두께의 측정자간 신뢰도는 훌륭하였으며, 경화반 존재유무에 대한 신뢰도는 적정하였다.

스캔 시간의 결정시기에 따른 총 스캔 시간 변화에 관한 연구 (The Change of Total Scan Time in Accordance with the Time of the Decision of Scan Time)

  • 이종훈;류재광;정우영
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.81-85
    • /
    • 2009
  • 목적 : 핵의학 검사에는 동일한 목적부위에 시간경과에 따른 변화를 관찰하고, 일정시간 동안에 여러 번 나누어 영상을 획득하는 검사들이 많이 있다. 이 때 동일한 영상 획득 조건이 적용되어야만 한다. Hepatobiliary scan, lung scan 등의 검사는 시간 간격을 두고, 여러 번의 영상을 획득하는 검사이다. 해당 검사 별로 최초의 영상에서 설정된 계수를 획득하기 위해 소요되는 시간을 연속되는 다음의 영상에 동일하게 적용하는 pre-set time을 설정한다. 이 때 각각의 영상에서 동일한 검사 시간이 적용되어야 한다. 이 연구는 pre-set time을 적용하는 검사에 스캔 시간의 결정시기에 따라 스캔 시간의 변동을 분석하고 이에 대한 합리적인 대안을 찾으려 한다. 실험재료 및 방법 : 2009년 1월부터 2009년 3월까지 서울아산병원 핵의학과에서 방사성의약품 $^{99m}Tc$-mebrofenin을 이용한 간담도 검사를 대상으로 하였다. 환자에게 222 MBq (6mCi)를 정맥주사한 후 5분이 지난 뒤에 스캔을 시작하였다. 두 개의 검출기를 서로 마주보게 하여, 환자가 양쪽 검출기 사이에서 erect position을 유지하도록 하였고 환자는 복부 전면을 검출기에 최대한 밀착하였다. 스캔을 시작한 후 총 검사시간의 10%, 25%, 50%, 75%일 때 예상 검사 종료 시간을 측정하였다. 이 측정시간을 스캔이 모두 끝난 후에 최종 검사시간과 검사 도중 예상되는 스캔 시간을 비교하였다. 그리고 팬텀을 이용하여 선량에 따른 시간 변화를 관찰하였다. 결과 : 스캔을 시작하고 스캔 시간이 총 예상 스캔 시간의 10% 되었을 때, 25% 되었을 때, 50% 되었을 때, 75% 되었을 때의 차이는 10%일 때 최대 5초 이상의 시간차이를 보였으며, 25% 되었을 때(t:2.88, p<0.01)와 50%가 되었을 때 (t:2.05, p<0.01) 통계적으로 유의한 차이가 있었다. 결론 : 스캔이 모두 종료된 후에 스캔 시간을 결정하는 것이 가장 정확한 측정치를 가지지만, 실무현장에 적용에는 다소간의 어려운 점이 있었다. 이것은 정량분석이 필요한 검사에 부정확한 결과치를 초래 할 수 있고, 이를 개선하려는 검사자의 노력이 필요한 것으로 판단된다. 스캔을 시작하고 최소한 총 스캔시간의 약 50% 이상이 지난 후에, 총 스캔시간을 결정하는 것이 영상간의 불일치하는 스캔시간으로 유발되는 정량 분석 오차를 최소화 할 수 있다는 것을 의미한다.

  • PDF

치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구 (The Study on the Protection and Actual Condition of Using the Dental X-ray Unit)

  • 강은주;유병규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF

인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가 (Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography)

  • 공창기;송종남;정문택;한재복
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.613-621
    • /
    • 2019
  • 하지 혈관조영검사에서 움직임을 줄이기 위한 방법으로 재질별 하드보드지, 포맥스, 폴리카보네이트, 아크릴을 사용하여 고정용 보조기구를 제작하였고, 제작된 재질별 Phantom의 정량적 화질평가를 위해 마스크 영상, DSA 영상, Roadmap 영상을 SNR과 CNR로 분석하여 보조기구의 유용성을 알아보고자 하였다. DSA 기법으로 하지 Phantom 만을 사용하여 촬영한 마스크 영상과 보조기구 위에 하지 Phantom을 올려놓고 촬영한 마스크 영상의 SNR과 CNR을 비교한 결과 SNR은 약 0~0.06(0~10%), CNR은 약 0~0.003(0~5.36%)정도의 낮은 차이를 확인 하였다. DSA 기법으로 혈관모형의 Water Phantom 만을 사용하여 촬영한 영상과 보조기구 위에 Water Phantom을 올려놓고 촬영한 영상의 SNR과 CNR을 비교한 결과 SNR은 약 0.11~0.35(0.78~2.47%), CNR은 약 0.016~0.031(0.18~2.85%) 정도의 낮은 차이를 확인 하였다. Roadmap 기법으로 Water Phantom 만을 사용하여 촬영한 영상과 보조기구(하드보드지, 포맥스, 폴리카보네이트, 아크릴) 위에 water Phantom을 올려놓고 촬영한 영상의 SNR과 CNR을 비교한 결과 SNR은 0.02~0.05(0.54~1.38%), CNR은 0.002~0.004(1.96~3.70%) 정도의 낮은 차이를 확인 하였다. 결과적으로 보조기구를 사용하지 않았을 때와 보조기구(하드보드지, 포맥스, 폴리카보네이트, 아크릴)을 사용하였을 때를 비교 했을때 SNR과 CNR의 차이가 낮아 보조기구의 사용이 화질의 미치는 영향이 적다고 판단된다. 환자 고정을 위한 보조기구의 사용은 움직임에 따른 조영제 사용량 감소, 시간적 측면 감소, 방사선 피폭 감소, 위험요소의 제거 등에 유용하게 사용할 수 있으며, 보조기구 제작에 대한 각각재료들의 장점은 많으나 본 연구에서 하드보드지 경우 다른 재료에 비해 가격이 저렴하고, 가공이 쉬운 장점을 가지고 있어 검사 및 시술에서 쉽게 적용이 가능할 것으로 판단된다. 검사자가 보조기구를 제작하여 사용 할 때 각 검사의 목적 및 방법에 맞게 재질의 특성, 경제성을 고려하여 사용하는 것이 유용할 것으로 판단된다.

러버댐에 대한 소아, 청소년 및 보호자에 대한 선호도 조사 (Survey on Preferences Regarding Rubber Dams in Children, Adolescents and Parents)

  • 정한글;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제43권1호
    • /
    • pp.17-26
    • /
    • 2016
  • 러버댐 방습은 환자와 술자를 보호하고 양질의 치료 결과를 얻기 위해 소아, 청소년 환자 치료 시 매우 유용하게 사용되고 있는 술식으로 다양한 장점을 가지고 있으나, 일부 환자들은 이에 불편감을 호소하기도 한다. 본 연구는 러버댐 방습에 대한 환자 및 보호자들의 선호도와 그에 미칠 수 있는 요인들에 대해 알아보기 위하여 계획되었다. 비진정치료 하에 ${\bigcirc}{\bigcirc}$대학교 치과병원 소아치과, 보존과, 일차외래에 내원하여 러버댐을 착용하에 치료를 받은 4-18세 환자들을 대상으로 작성된 설문지를 전자 차트 기록을 통하여 취합하였다. 환아들은 러버댐 방습에 대해 긍정적으로 생각하는 경향을 보였고, 치과 치료에 대해 긍정적으로 생각하는 그룹이 러버댐 방습에 대해서도 더 긍정적으로 생각하는 것으로 나타났다. 치료 시간이 짧은 그룹, 러버댐 방습에 대한 지식 및 경험이 있는 그룹에서 러버댐 방습에 대한 태도가 더 긍정적인 것으로 나타났으며(p < 0.05), 성별, 나이, 치료 내용, 마취 여부, 치료 부위, 술자 요인에 대해서는 유의한 차이가 관찰되지 않았다(p > 0.05).

네 가지 전동 Ni-Ti 파일의 danger zone에서의 근관성형력 (Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone)

  • 최석동;진명욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.446-453
    • /
    • 2004
  • 하악 대구치 근심치근의 danger zone에서 수종의 전동 니켈-티타늄 파일의 근관성형력을 근관성형 전후 치질 두께의 변화를 측정하여 평가하고자 하였다. 기구에 따라 총 40개의 하악 대구치를 10개씩 $Profile^{\circledR}$, GT Rotary file, Quantec 및 ProTaper 4개 군으로 나누고 각 치아당 2개의 근관을 straight up-and-down과 anticurvature 군으로 나누어 근단부 근관을 모두 30번 크기로 일정하게 확대하였다. 수정된 Bramante법을 사용하였으며 술전 및 술후의 근관 상아질 두께를 치수저 하방 1, 3 및 5 mm지점에서 측정, 이원변량분석법으로 통계분석하였다. 모든 군의 danger zone과 safe zone에서의 straight up-and-down 동작과 anticurvature 동작 사이에는 치근상아질 두께변화에 현저한 차이를 나타내지 않았다 (p > 0.05). ProTaper는 danger zone과 safe zone 모두에서 다른 기구에 비해 많은 량의 근관상아질 삭제를 보였으며 특히 분지부 3 mm 수준에서 현저하였다(p < 0.05).

섹터모드의 로스비하우어비츠 파동과 균형을 이루는 고도장 (Geopotentinl Field in Nonlinear Balance with the Sectoral Mode of Rossby-Haurwitz Wave on the Inclined Rotation Axis)

  • 정형빈;박자린
    • 한국지구과학회지
    • /
    • 제28권7호
    • /
    • pp.936-946
    • /
    • 2007
  • 기울어진 자전축을 갖는 회전계에서, 일정한 각속도로 회전하는 동서풍이 있는 경우에 대해서 로스비하우어비츠 파동의 섹터모드(적도에 대한 반구 비대칭의 첫 번째 모드)와 균형을 이루는 지위고도장을 해석적으로 유도하였다. 균형장은 발산방정식으로부터 시간변화를 제거하고 라플라시안 연산자를 역산함으로써 구하였다. 역산은 비선형항의 계산과 포이슨 방정식의 해를 구하는 두 단계의 연산과정으로 이루어져 있다. 두 번째 단계에서, 구면조화함수로 표현되는 강제력의 항은 구면조화함수의 선형관계를 이용하였고, 그 이외의 항은 구면조화함수를 적분함으로써 구하였다. 균형장은 여섯 개의 동서파수 성분으로 표현됨이 드러났다. 본 연구에서 구한 균형장은 적도에 대하여 비대칭의 구조를 가지기 때문에, 대칭의 구조만을 가지는 것에 비하여 미분방정식의 수치해의 검종법으로서의 활용도가 높다. 일정한 각속도를 갖는 배경 동서풍이 지구의 자전각속도와 같거나 1/2에 해당하는 경우에는, 일부 동서파수 성분이 제거되는 것으로 나타났다. 이론적으로 구한 균형장은 정교한 수치모델을 통하여 구한 균형장과 거의 정확하게 같은 것으로 밝혀져, 이론적 해의 타당성이 입증되었다. 마지막으로, 로스비하우어비츠 파동의 섹터모드와 균형을 이루는 지위고도장의 안정성을 장기간시간적분을 통하여 살펴보았다.

서남해 해상풍력발전단지 내 항로형태에 따른 선박통항 위험도 평가에 관한 연구 (Study on Vessel Traffic Risk Assessment according to Waterway Patterns in a Southwest Offshore Wind Farm)

  • 장다운;김득봉;정재용
    • 해양환경안전학회지
    • /
    • 제25권6호
    • /
    • pp.635-641
    • /
    • 2019
  • 서남해 해상풍력발전단지 내 선박 통항 금지와 조업 제한으로 인해 사업자와 어민간의 갈등이 심화되고 있다. 이러한 문제 해결을 위하여 국내에서도 유럽의 해상풍력발전단지와 같이 발전단지 내 선박 통항과 어로작업 허용을 검토하고 있다. 이 연구는 서남해 해상풍력발전단지 내 선박 통항을 가정하여 항로의 형태에 따른 해상교통위험도 발생비율을 ES 모델과 IWRAP을 이용하여 분석하였다. 또한, 항로의 형태(십자형 항로 및 격자형 항로)와 선박 통항량(현재, 3배, 5배, 10배)에 변화를 주어 위험도를 정량적으로 평가하였다. 주요 평가결과는 다음과 같다. 현재의 교통량에서 십자형 항로와 격자형 항로를 운영할 경우 조선부담감(종합환경스트레스치가 750 이상)이 높은 구간은 발생하지 않았으며, 연간 충돌확률도 큰 차이가 발생하지 않았다. 그러나 통항량이 현재보다 3배, 5배, 10배 증가함에 따라 교차지점에서 조선부담감과 연간 충돌확률이 급격히 증가함을 확인하였으며, 이를 통해 격자형 항로에서 교통류 분리를 통해 위험도를 효과적으로 분산시킬 수 있다는 것을 알 수 있었다. 본 연구의 결과는 서남해 해상풍력발전단지 내에서 항로설정, 항로운영방식, 안전대책 등에 활용이 가능할 것으로 기대된다.

만성 폐쇄성 폐질환(COPD) 환자에서 운동 시 발생하는 산소 불포화 반응과 관련된 인자 (Factors Related to Exertional Oxygen Desaturation in Patients with COPD)

  • 심상우;조준연;권용식;채진녕;박지혜;이미영;노병학;최원일
    • Tuberculosis and Respiratory Diseases
    • /
    • 제70권6호
    • /
    • pp.498-503
    • /
    • 2011
  • Background: The causes of exertional desaturation in patients with COPD can be multifactorial. We aimed to investigate factors predict exertional desaturation in patients with moderate to severe COPD. Methods: We tested 51 consecutive patients with stable COPD (FEV1/FVC, $40{\pm}13%$ predicted). Patients performed a six minute walk test (6MWT). Pulse oxymetric saturation (SpO2) and pulse rate were recorded. Results: Oxygen desaturation was found in 15 subjects after 6MWT, while 36 subjects were not desaturated. Lung diffusing capacity was significantly lower in desaturation (DS) group ($62{\pm}18%$ predicted) compared with not desaturated (ND) group ($84{\pm}20$, p<0.01). However there was no statistical difference of FEV1/FVC ratio or residual volume between two groups. The pulse rate change was significantly higher in the desaturated compared with the not desaturated group. Six minute walking distance, subjective dyspnea scale, airflow obstruction, and residual volume did not predict exertional oxygen desaturation. Independent factors assessed by multiple logistic regression revealed that a pulse rate increment (odd ratio [OR], 1.19; 95% confidence interval [CI], 1.01~1.40; p=0.02), a decrease in baseline PaO2 (OR, 1.105; 95% CI, 1.003~1.218; p=0.04) and a decrease in lung diffusing capacity (OR, 1.10; 95% CI, 1.01~1.19; p=0.01) were significantly associated with oxygen desaturation. Receiver operator characteristic (ROC) analysis showed that an absolute increment in pulse rate of 16/min gave optimal discrimination between desaturated and not desaturated patients after 6MWT. Conclusion: Pulse rate increment and diffusion capacity can predict exertional oxygen desaturation in stable COPD patients with moderate to severe airflow obstruction.