• 제목/요약/키워드: Difference Voltage

검색결과 1,059건 처리시간 0.038초

Extensional 진동 모드를 이용한 압전 트랜스포머의 감압 특성 (Step-Down Voltage Properties of Piezoelectric Transformer with Extensional Vibration Mode)

  • 최지현;방규석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.652-655
    • /
    • 2003
  • In this paper, step-down piezoelectric transformer is studied. The piezoelectric transformer, made of lead zirconate titanate solid solution ceramic, is operated by a fundamental contour-extensional vibration mode. The transformer of 14mm length, 14mm width and 4.5mm thickness was made up two shape(Type I and II). The resonant frequency (fr) is 144kHz and 128kHz at the load resistant of $7.5{\Omega}$ that is a similar to calculating matching impedance. The gain (G) obtained 0.19 and 0.08 at each resonant frequency, when applied input voltage is 25V. The temperature difference with the variation of load resistant was increased with increasing load resistant and was the lowest at $7.5{\Omega}$ near the matching of output impedance.

  • PDF

입력전압에 비례하는 주파수 신호 생성 회로의 설계 (A Design of Voltage-to-Frequency Converter)

  • 최진호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.189-192
    • /
    • 2002
  • In this work, a Voltage-to-Frequency Converter.(VFC) in which the output frequency is proportional to the input voltage is proposed. To obtain temperature stable characteristics the VFC is designed by using two bandgap references. The difference between simulated and calculated values is less than about 5% in output characteristics. In the VFC using BiCMOS the temperature variation of sample output frequencies is less than $\pm$0.5% in the temperature range -$25^{\circ}C$ to 75$^{\circ}C$. And the CMOS VFC has error less than $\pm$0.8% in the temperature range -$25^{\circ}C$ to 75'$^{\circ}C$.

  • PDF

상온에서 짧은 채널 n-MOSFET의 이동도 감쇠 변수 추추에 관한 연구 (A Study on the Extraction of Mobility Reduction Parameters in Short Channel n-MOSFETs at Room Temperature)

  • 이명복;이정일;강광남
    • 대한전자공학회논문지
    • /
    • 제26권9호
    • /
    • pp.1375-1380
    • /
    • 1989
  • Mobility reduction parameters are extracted using a method based on the exploitatiion of Id-Vg and Gm-Vg characteristics of short channel n-MOSFETs in strong inversion region at room temperature. It is found that the reduction of the maximum field effect mobility, \ulcornerFE,max, with the channel length is due to i) the difference between the threshold voltage and the gate voltage which corresponds to the maximum transconductance, and ii) the channel length dependence of the mobility attenuation coefficient, \ulcorner The low field mobility, \ulcorner, is found to be independent of the channel length down to 0.25 \ulcorner ofeffective channel length. Also, the channel length reduction, -I, the mobility attenuation coefficient, \ulcorner the threshold voltage, Vt, and the source-drain resistance, Rsd, are determined from the Id-Vg and -gm-Vg characteristics n-MOSFETs.

  • PDF

원전 안전등급 저전압계전기 설정시 오차함수 검토 (Review on tolerance factors for 1E UVR setting at NPPs)

  • 문수철;김건중
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.367-372
    • /
    • 2012
  • In nuclear plants, UVR (under voltage relay, 27r) of 1E bus, which protected and supplied power to essential loads, to safety trip of reactor and supplied to starting signal of EDG (emergency diesel generators) automatically. therefore UVR tolerances setting and calculation method has been important to nuclear facility. If calculation and tolerances values differ or ignore, may induced power loss and economical loss by protective failure. This paper show results for calculation methods, and whether dependant or independent methods for factors. included whether PT (potential transformer/voltage transformer) tolerance or not adapted, and based on UVR setting method within a difference minimum and maximum of rated voltage to safety operation in nuclear plants.

A Low Dynamic Power 90-nm CMOS Motion Estimation Processor Implementing Dynamic Voltage and Frequency Scaling Scheme and Fast Motion Estimation Algorithm Called Adaptively Assigned Breaking-off Condition Search

  • Kobayashi, Nobuaki;Enomoto, Tadayoshi
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.512-515
    • /
    • 2009
  • A 90-nm CMOS motion estimation (ME) processor was developed by employing dynamic voltage and frequency scaling (DVFS) to greatly reduce the dynamic power. To make full use of the advantages of DVFS, a fast ME algorithm and a small on-chip DC/DC converter were also developed. The fast ME algorithm can adaptively predict the optimum supply voltage ($V_D$) and the optimum clock frequency ($f_c$) before each block matching process starts. Power dissipation of the ME processor, which contained an absolute difference accumulator as well as the on-chip DC/DC converter and DVFS controller, was reduced to $31.5{\mu}W$, which was only 2.8% that of a conventional ME processor.

  • PDF

LED driver에서의 정전류 및 정전압 제어의 비교 연구 (A Comparison of Constant Current and Constant Voltage Control in LED Driver)

  • 한수빈;박석인;정학근;송유진;정봉만
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.83-84
    • /
    • 2010
  • This paper reviews the performance difference between constant voltage control and constant current control in LED driver. Simulations of both control methods are performed for performance comparison especially with temperature variation. The results show that constant current control method is inherently better than constant voltage control for LED drive.

  • PDF

전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술 (Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment)

  • 정재갑;박영태;권성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권9호
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

A Protection Technique Against the Damages Caused by Lightning Surges on Information and Communication Facilities

  • Lee, Bok-Hee;Kang, Sung-Man;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.117-122
    • /
    • 2003
  • The AC power lines and signal lines of info-communication networks are routed on overhead poles and are highly exposed to lightning strikes. Due to the potential difference between grounding points of AC power lines and signal lines, the electronic equipments connected to the signal lines can easily be damaged by lightning surges. In this work, in order to develop reliable methods of protecting information and communication facilities from lightning surges, the reliability and performance of SPDs (surge protective devices) were experimentally investigated in an actual-sized test circuit. The behaviors of SPDs against lightning surges from AC power lines and signal lines and the coordinated effects of SPD installation methods were evaluated. As a consequence, it was confirmed that the bypass arrester methods and common grounding system are both highly effective.

IGBT를 이용한 전동차용 보조전원장치의 소음 저감에 관한 연구 (A Study on Noise Reduction for Auxiliary Power Supply of railway Vehicle Using IGBT)

  • 노애숙;김주범;배기훈;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.280-286
    • /
    • 1998
  • In recent years, the interest in noise increases gradually and the low noise level becomes one of the important performances in electrical equipment for railway vehicle. In the auxiliary power supply, most of the noise is made by the current ripple of alternating current reactor(ACL) which filters the output voltage. And this current ripple results from the voltage harmonics across the ACL. So the noise can be reduced by eliminating the voltage harmonics across the ACL. This paper shows harmonic eliminating technique which is making gating signals of upper and lower inverter have a phase difference in the 12-step inverter type auxiliary power supply. This technique was proved by testing on the developed 180KVA auxiliary power supply using IGBT.

  • PDF

열전소자를 이용한 냉·온장시스템 개발 (Development of Cooling/Warming System Using Thermoelectric Device)

  • 김기환
    • 한국인터넷방송통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.131-136
    • /
    • 2009
  • 열전효과란 온도차를 전기적인 크기 즉 전압으로 변환시키는 것을 말한다. 또한 그 반대의 경우도 여기에 해당한다. 연전 소자는 소자의 영면에 온도 차가 존재할 때 전압이 발생하며 반대로 이 소자에 전압을 가할 경우 온도차가 발생하는 소자이다. 본 논문에서는 물질을 냉각과 가열을 할 수 있게 이러한 현상을 이용하여 열전소자를 사용한 냉 온장 시스템을 소개하였으며 PC와 LabVIEW를 이용하여 냉 온장 시스템을 제어하였다.