• Title/Summary/Keyword: Difference Pressure

Search Result 3,915, Processing Time 0.042 seconds

Possible Effect of Western North Pacific Monsoon on Tropical Cyclone Activity around East China Sea (북서태평양 몬순이 동중국해 주변의 태풍활동에 미치는 영향)

  • Choi, Jae-Won;Cha, Yumi;Kim, Jeoung-Yun
    • Journal of the Korean earth science society
    • /
    • v.38 no.3
    • /
    • pp.194-208
    • /
    • 2017
  • This study analyzed the correlation between tropical cyclone (TC) frequency and the western North Pacific monsoon index (WNPMI), which have both been influential in East China Sea during the summer season over the past 37 years (1977-2013). A high positive correlation was found between these two variables, but it did not change even if El $Ni{\tilde{n}}o$-Southern Oscillation (ENSO) years were excluded. To determine the cause of this positive correlation, the highest (positive WNPMI phase) and lowest WNPMIs (negative WNPMI phase) during an eleven-year period were selected to analyze the mean difference between them, excluding ENSO years. In the positive WNPMI phase, TCs were mainly generated in the eastern seas of the tropical and subtropical western North Pacific, passing through the East China Sea and moving northward toward Korea and Japan. In the negative phase, TCs were mainly generated in the western seas of the tropical and subtropical western North Pacific, passing through the South China Sea and moving westward toward China's southern regions. Therefore, TC intensity in the positive phase was stronger due to the acquisition of sufficient energy from the sea while moving a long distance up to East Asia's mid-latitude. Additionally, TCs occurred more in the positive phase. Regarding the difference in 850 hPa and 500 hPa stream flows between the two phases, anomalous cyclones were strengthened in the tropical and subtropical western North Pacific, whereas anomalous anticyclones were strengthened in East Asia's mid-latitude regions. Due to these two anomalous pressure systems, anomalous southeasterlies developed in East China Sea, which played a role in the anomalous steering flows that moved TCs into this region. Furthermore, due to the anomalous cyclones that developed in the tropical and subtropical western North Pacific, more TCs could be generated in the positive phase.

COMPARISON FOR THE RETENTION OF CASTING CROWN AND CEMENT THICKNESS FOLLOWING VARIOUS CEMENTS (수종의 세멘트에 따른 주조금관의 유지력 및 세멘트 두께의 비교)

  • Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 1994
  • The purpose of this study was to evaluate the effect of various cements on the retention of casting crown and the cement film thickness. To evaluate the retention of crown, thirty maxillary premolars were used and prepared to largely same dimension. According to the routine method, Non-precious metal crowns were made. The teeth and the metal crowns were divided into three groups and cemented under 5kg static pressure. Group I was composed of 10 teeth and 10 metal crowns and was cemented with zinc phohsphste cement. Group II was composed of 10 teeth and 10 metal crowns and was cemented with Panavia-EX cement. Group III was composed of 10 teeth and 10 metal crowns and was cemented with All-Bond & composite resin cement. After 5 days, the cemented specimens were mounted and the failure loads were measured by an Instron Universal Testing Machine. To evaluate the cement film thickness. 5 metal teeth and 5metal crowns from a prepared maxillary premolar were made. Two marks were flawed on the margin part of each surface at 4-surfaces of each specimen(one mark : crown, the other : metal tooth) and were measured the width with SEM photograph(80 sheets) before and after cementation(Panavia-EX, All-Bond cement, & ZPC) was made. Differences of the widths of marks between before and after were measured, and differences from 4-surfaces of a specimen cemented with a cement were measured and calculated. The results were as follows ; 1. There was a statistically significant difference between the failure loads of group III and the others(p<0.05). 2. There was a statistically significant difference between the cement film thickness of group III and the others(p<0.05).

  • PDF

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

Effects of an Improved Side Vent on Yield of Oriental Melon and Temperature in Single-span Plastic Greenhouse with Roof Ventilation Fans (지붕 환기팬이 설치된 단동 플라스틱 온실에서 개선된 측창형태가 하우스 내 온도 및 참외 수량에 미치는 영향)

  • Yu, In Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Shin, Young An
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • In this study, the method to attach plastic film on the side vent from inside of greenhouse for the entire length was developed as the way to make crops less stressful while uniformly getting outside air into the greenhouse when ventilating using roof ventilation fans at single-span plastic greenhouse for oriental melon in a low-temperature period. The plastic film was installed from ground to 10cm below from the height where side vent is fully opened. In order to verify that the improved side vent can improve greenhouse environment and fruit yield, it was compared with the control plot of conventional side vent. Both greenhouses were not ventilated until February 25th, 2017. Air temperature in both greenhouses exceeded $40^{\circ}C$ in mid February. Therefore, it is judged that the greenhouse should be ventilated from mid February. Air temperature in the control plot exceeded $30^{\circ}C$ from late April. Therefore, it is judged that the plastic film attached to the inside of side vent should be removed in late April, or in early May at the latest. Soil temperature in the treatment plot in the mid Aril exceeded $20^{\circ}C$, which is suitable for growth, while that in the control plot was still below $20^{\circ}C$. Soil temperature in the control plot finally exceeded $20^{\circ}C$ in late April. The consumption of electricity was 47.2 kWh in the treatment plot, and 48.3 kWh in the control plot, which was no significant difference. The marketable yield of oriental melon in the treatment plot was 5,094kg, which was 23.9% more than that in the control plot, 4,113kg. The marketable fruit ratio was 73.5% in the treatment plot, and that in the control plot was 73.9%, which was no significant difference.

Influence of Micrometeorological Elements on Evapotranspiration in Rice (Oryza sativa L.) Crop Canopy (포장(圃場)에서 벼 군락(群落)의 미기상(微氣象) 요소(要素)들이 증발산량(蒸發散量)에 미치는 영향(影響))

  • Kim, Jong-Wook;Kang, Byeung-Hoa;Lee, Jeong-Taek;Yun, Seong-Ho;Im, Jeong-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.25 no.3
    • /
    • pp.231-241
    • /
    • 1992
  • To study the relationships between major micrometeorological elements and their influences on evapotranspiration(ET) in the canopy of two rice cultivars, Daecheongbyo and Samgangbyo, synoptic meteorological factors, micrometeorological elements and ET from the canopy and biomass production were observed at various growth stages in the paddy field of Suwon Weather Forcast Office in 1989. ET from the rice community was highly correlated with the following factors in order of pan evaporation>air temperature>leaf temperature>solar radiation>sunshine duration>difference in vapor pressure depicit(VPD)>water temperature. ET observed showed higher correlation with the evaporation from small pan than that from Class A pan. Varietal difference would be noted in the relationships between ET in Samgangbyo canopy and the evaporations observed from the pans, with which closer a correlation was found in Samgangbyo than in Daecheongbyo. The ratio of canopy ET to the evaporation from Class A pan was maintained over 1.0 through the growth stages with the maximum of 1.9 at the late August. The evaporation observed from Class A pan was amounted to 71.9% of that from small pan. ET was better correlated with solar radiation than with net radiation which reached about 66% of solar radiation. Maximum temperature showed higher correlation with ET than mean air temperature, and also wind speed of 1m above ground revealed positive correlation. The relative humidity, however, had no correlation with the exception of ET in rainy days. A regression model developed to estimate ET as a function of meteorological elements being described with $R^2$ of 0.607 as : $ET=-5.3594+0.7005Pan\;A+0.1926T_{mean}+0.0878_{sol}+0.025RH$.

  • PDF

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

The Effect of Human Albumin Infusion on the Clinical Course of Steroid Sensitive Nephrotic Syndrome (인알부민 투여가 스테로이드 반응성 신증후군의 임상경과에 미치는 영향)

  • Lee Soo Jin;Jeong Ji A;Hwang Soo Ja;Lee Seung Joo
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.102-110
    • /
    • 2000
  • Purpose : Intravenous infusion of albumin has been widely und to relieve severe nephrotic edema in spite of beneficial or harmful effects. The purpose of this study is to examine the harmful effect of albumin on the clinical course of steroid sensitive nephrotic syndrome(SSNS). Method : We prospectively randomized the patients with nephrotic syndrome(biopsy proven or clinically compatible to minimal change nephrotic syndrome) into the albumin group(20$\%$ albumin 1 g/kg) or control group(5$\%$ D/W) between March 1997 and September 1999 at Ewha University Mokdong Hospital. We compared the clinical course of the albumin group(n=13) with the control group(n=13). Results : 1. The duration of steroid therapy until complete remission in the albumin group was significantly longer than the control group($13.7{\pm}6.4\;days\;vs\;7.5{\pm}2.8\;days$)(P<0.05). 2. The remission duration to the first relapse was significantly shorter in the albumin group ($94{\pm}63.5$ days) than the control group($190{\pm}106.4$ days)(P< 0.05). There was no significant difference in the relapse rate within 1 year after complete remission[77$\%$ (10/13) vs 46$\%$ (6/13)](P>0.05) and the relapse frequency per year($1.9{\pm}0.8\;vs\;1.5{\pm}0.5$) between the albumin and control groups. 3. Spot urine protein/creatinine ratio significantly increased in the albumin group at post-albumin 2, 4 days(P<0.05). There was no significant difference in the change of the daily percent weight loss, blood pressure, serum Na, K concentration between the albumin and control groups. Conclusion : Albumin infusion in SSNS delayed the response to steroid and shortened the remission duration to the first relapse. Albumin should be carefully used in nephrotic edema.

  • PDF

Interdecadal Variation of Tropical Cyclone Genesis Frequency over the Western North Pacific (북서태평양에서 열대 저기압 발생빈도의 십년간 변동 특성)

  • Choi, Ki-Seon;Kim, Baek-Jo;Lee, Seong-Lo;Park, Jong-Kil
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.31-39
    • /
    • 2009
  • This study has found that there is a reverse phase with interdecadal variation in temporal variations of tropical cyclone (TC) genesis frequency (TCGF) between Northwest sector and Southeast sector, based on climatological mean tropical cyclone genesis location over the western North Pacific. The TCGF in the Northwest sector has been increased since the mid 1980s (1986-2005), while TCGF in the Southeast sector was higher until the early 1970s (1951-1970). The analysis of a difference between 1986-2005 and 1951-1970 showed results as follows: i) Through the analysis of vertical wind shear (VWS) and sea surface temperature (SST), less VWS and higher SST in the former (latter) period was located in the Northwest (Southeast) sector. ii) In the analysis of TC passage frequency (TCPF), TCs occurred in the Northwest sector frequently passed from east sea of the Philippines, through East China Sea, to Korea and Japan in the latter period, while TCs in the former period frequently has a lot of influences on South China Sea (SCS). In the case of TCs occurred in the Southeast sector, TCs in the west (east), based on $150^{\circ}E$ had a high passage frequency in the latter (former) period. In particular, TCs during the latter period frequently moved toward from the east sea of the Philippines to SCS and southern China. iii) This difference of TCPF between the two periods was characterized by 500 hPa anomalous pressure pattern. Particularly, anomalous cyclonic circulation strengthened over the East Asian continent caused anomalous southerlies along the East Asian coast line from the east sea of the Philippines to be predominate. These anomalous winds served as steering flows that TC can easily move toward same regions.

The Changes of Serum Angiotensin Converting Enzyme Activity in Lung Cancer Patients (폐암 환자의 혈청 Angiotensin Converting Enzyme 활성도의 변화)

  • Jeong, Ki-Ho;Choi, Hyung-Seok;Yoo, Chul-Gyu;Lee, Kye-Young;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.4
    • /
    • pp.310-317
    • /
    • 1992
  • Background: Angiotensin converting enzyme is a glycoprotein peptidyldipeptide hydrolase which cleaves the c-terminal dipeptides of several oligopeptides. It is a menbrane-bound protein mainly synthesized by the endothelial cells. Since the lung has the largest capillary bed of any organ in the body, it is here that ACE acts on circulating substrates like angiotensin I and bradykinin. It is well known that ACE correlates with disease activity in sarcoidosis and also there are reports that changes in serum ACE activity are found in many acute and chronic lung diseases. So we planned this study to see if serum ACE activity can act as a prognostic factor in lung cancer. Methods: Forty-one newly diagnosed lung cancer patients were included in the study group. There were 19 patients with squamous cell lung cancer, 13 with adenocarcinoma, and 9 with small cell carcinoma. Patients were excluded from the study if they had high blood pressure, heart disease, liver disease, renal disease, or other lung disease. Serum ACE activity was analyzed according to cell type, staging, mode of treatment, and clinical response to treatment. Results: 1) There was no difference in serum ACE activity between lung cancer patients and the control group. Also no difference in serum ACE activity was found according to cancer cell type or staging. 2) In patients who underwent curative resection of lung cancer, serum ACE activity was decreased significantly after the operation. 3) In patients who were diagnosed as non-small cell lung cancer and were treated with 4 cycles of anti-cancer chemotherapy without clinical improvement, changes in serum ACE activity were not seen after the treatment. 4) In patients diagnosed as small cell lung cancer treated with 4 cycles of anti-cancer chemotherapy with clinical improvement, changes in serum ACE activity were also not observed. Conclusion: Serum ACE activity was decreased after lung resection but had no relation to cell type, staging, or clinical response to treatment in lung cancer patients. Therefore, serum ACE activity is not suitable in predicting clinical outcome of lung cancer patients.

  • PDF

The Prognostic role of Electrocardiographic Signs of Cor Pulmonale in Chronic Obstructive Pulmonary Disease (폐성심을 시사하는 심전도 소견 유.무에 따른 만성폐쇄성 폐질환 환자의 예후)

  • Shin, Moo-Chul;Park, Jae-Yong;Bae, Moon-Seob;Bae, Nack-Cheon;Chae, Po-Hee;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.944-955
    • /
    • 2000
  • Background : In patients with chronic obstructive pulmonary disease(COPD), several factors have been associated with a poor prognosis. These include old age, low $FEV_1$ low diffusing capacity, high alveolar-arterial oxygen pressure difference, and finally cor pulmonale. This study was done to investigate if the ECG signs suggesting cor pulmonale were independent prognostic factors in patients with COPD. Method : We analyzed ECG, pulmonary function data and arterial blood gas values in 61 patients who were admitted through the emergency department with an acute exacerbation of COPD. The ECG signs reflecting cor pulmonale were right strial overloading(RAO), right bundle branch block, right ventricular hypertrophy and low-voltage QRS. The 61 patients were divided into 2 groups ; group I with no ECG signs(n=36) and group II with one or more ECG signs(n=25) suggesting cor, pulmonale. Results : Poor, prognostic factors by univariate analysis were low $FEV_1$, $FEV_1$ % pred., VC % pred., DLco, DLco % pred., $PaO_2$ and $SaO_2$ high $PaCO_2$ presence of ECG signs reflecting cor pulmonale, presence of mental status change, use of mechanical ventilator, and long term use of glucocorticoid. A multivariate analysis indicated that age(risk ratio=1.13, 95% confidence interval 1.05-1.23), DLco % pred. (risk ratio=0,97. 95% confidence interval 0.94-0.99), $PaO_2$ (risk ratio=0.95, 95% confidence interval 0.90-0.99) and RAO(risk ratio=5.27, 95% confidence interval 1.40-19.85) were independent prognostic factors of survival. There was a significant difference in survival between the patients with and without RAO(p=0.038). The survival rates at 1, 2, and 5 years were 94.5%. 81.4%, and 50.0% in patients without RAO and 82.4%, 70.6%, and 27.5% in patients with RAO, respectively. Conclusion : These results suggest that the presence of ECG signs reflecting cor pulmonale is a predictor of survival and that RAO of these ECG signs is a significant independent predictor of survival in patients with COPD.

  • PDF